Dissolution of gypsum rock in water is significant, which may result in hydrocarbon reservoir formation and evaporate deposits. However, the complexity of the gypsum dissolution process is still of interest because of its uncleanness that requires more critical analysis. The objectives of this experimental study are emphasis on the dissolution characteristics of gypsum rock under room temperature and by various types of water; namely: deionized, tap, fresh, acidic, well, and normal rainwatre. In addition, the influences of dissolution on gypsum rock's mechanical and physical characteristics. Gypsum rock was obtained from Agjalar area, in the southwest of Sulaymaniyah city, Northern Iraq. Experimental results show that well water is the most effective type to dissolve gypsum and cause significant reductions in the mechanical characteristics of gypsum rock.
Increased diseases and obesity currently due to increased production and excessive consumption of foods manufactured from non-food sweeteners without attention to the risk of consuming those additional high calories due to consuming these refreshing products such as juices and other various drinks, especially in the summer season by most segments of Iraqi society, especially workers, children and school students the aim of this study. Therefore, the study designed to replace sucrose with 0.03, 0.04 and 0.05% of each of the white stevia crystals and milled dry stevia leaves in the laboratory manufacture of juices and its effect on the general and sensory characteristics and the extent of their acceptability among the specialized r
... Show MoreBackground: Chronic cigarette smoking is one of the major risk factors for coronary artery disease. However, it has additional cardiac adverse effects independent of coronary atherosclerosis. Patient and Methods: After informed consent and perm- ission from the review board of the hospital, 80 healthy subjects who were classified as smokers or non-smokers were included in the study. They were examined by standard echocardiography protocol which was followed by two-dimensional speckle tracking to assess the functions of the right ventricle. Results: The tricuspid annular plane systolic excursion (TAPSE) was significantly reduced in smokers as compared to non-smokers (P < 0.05). The tricuspid flow peak late diastolic velocity (A wave) was sig
... Show MoreExperimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w
This research sheds light on the physical environment role in creating the place attachment, by discussing one of the important factors in the attachment creation, it is the concept place dependence, consisting of two important dimensions: the place quality and the place expectation; they contain a number of the supporter physical environment sub-indicators for place attachment. Eight physical indicators were reached; they were found to have a close relationship to the place attachment, including: the open and green spaces existence, land use diversity, diversity of housing types, dwelling / population density, accessibility, transport network development degree, transport multiple mo
Refrigerant R134a has been widely utilized in automotive air conditioning systems (AACSs); R134a has a high global warming potential (GWP) of 1430 despite having zero ozone depletion potential (ODP). Coming refrigeration systems must include refrigerants with low GWP and zero ODP. The aim of this experimental study is to evaluate the thermal performance of an (AAC) with different values of compressor speeds, i.e., (1000, 1700, and 2400 rpm) and two thermal loads, i.e., (500 and 1000 Watt) with the absence and presence of liquid suction heat exchanger (LSHX) using R134a. The results showed that adding LSHX enhanced the COP cycle by 7.18%, 10.7%, and 3.09% for the first, second, and third speed, respectively, at 500 Watt, while the en
... Show MoreThe aim of the research is to identify the reality of administrative motivation for the deans of the faculties of physical education and sports sciences at the universities of Baghdad and Al-Mustansiriya from the point of download of the faculty members. The number of the exploratory sample was (7) faculty members, they were taken in a random way, while the rest of the sample number was (150) faculty members who considered the application sample for the scale, and the two researchers also adopted a questionnaire for the scale and it is applied to the Iraqi environment. phrase, which are phrases that are interrelated with the administrative leadership motivation in the faculties of physical education and sports sciences. The researchers did
... Show MoreThis research investigated the influence of water-absorbent polymer balls (WAPB) on reinforced concrete beams’ structural behavior experimentally. Four self-compacted reinforced concrete beams of identical geometric layouts 150 mm × 200 mm × 1,500 mm, reinforcement details, and compressive strength
One of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model a
... Show MoreOne of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model at elevated t
... Show More