Preferred Language
Articles
/
joe-1663
Water Quality Assessment of Al-Najaf City Potable Water Network
...Show More Authors

 Water is an essential aspect of life and important in evolution. Recently the potable water quality topic has received much attention. The study aims to determine drinking water quality in Al-Najaf City by collecting samples throughout Al-Najaf city and comparing the results with the Iraqi guidelines (IQS 417) and World Health Organization (WHO) guidelines, as well as to calculate the WQI. Samples were tested in the laboratory between December 2021 and June 2022. The results showed that multiple parameters exceeded the allowable limits during both testing periods; during winter months, the results of TDS and turbidity exceeded the upper limits in multiple locations. Total hardness values also exceeded the limit of 500 ppm for all samples taken in the winter period. For magnesium and calcium, summer measurements were mainly within limits, unlike winter period measurements which mostly exceeded the limits. Residual chlorine tests in winter had higher concentrations, generally ranging from 0.25 to 0.8 mg/l. While During summer, concentrations dropped below the allowable limit in multiple sampling points. The study concluded that the majority of the water samples gathered during the winter months were of poor quality as the total WQI values were between (99-110), While the total WQI values for water samples collected during the summer period were rated as good quality water ranged between (75-81).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression ana

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al- Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regressio

... Show More
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
The seasonal effect on the water bodies in Iraqi marshlands
...Show More Authors

Scopus (5)
Scopus
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Brackish Water Desalination Coupled With Wastewater Treatment and Electricity Generation
...Show More Authors

A new bio-electrochemical system was proposed for simultaneous removal of organic matters and salinity from actual domestic wastewater and synthetically prepared saline water, respectively. The performance of a three-chambered microbial osmotic fuel cell (MOFC) provided with forward osmosis (FO) membrane and cation exchange membrane (CEM) was evaluated with respect to the chemical oxygen demand (COD) removal from wastewater, electricity generation, and desalination of saline water. The MOFC wasinoculated with activated sludge and fueled with actual domestic wastewater. Results revealed that maximum removal efficiency of COD from wastewater, TDS removal efficiency from saline water, power density, and current density were

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Desalination And Water Treatment
Reducing endotoxin from dialysis water by using different disinfection processes
...Show More Authors

View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Energy Generation from Static Water Head Developed By Forward Osmosis
...Show More Authors

In this work, the possibility of utilizing osmosis phenomenon to produce energy as a type of the renewable energy using Thin Film Composite Ultra Low Pressure membrane TFC-ULP was studied. Where by forward osmosis water passes through the membrane toward the concentrated brine solution, this will lead to raise the head of the high brine solution. This developed static head may be used to produce energy. The aim of the present work is to study the static head developed and the flux on the high brine water solution side when using forward and reverse osmosis membranes for an initial concentration range from 35-300 g/l for each type of membrane used at room temperature and pressure conditions, and finally calculating the maximum possible po

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Biological & Immunological Effect of Ozonated Water on Certain Skin Pathogenic Bacteria In vivo
...Show More Authors

This in vivo study was conducted to investigate the effect of different concentrations of ozonated water on experimentally skin infection with some of bacterial isolates (Pseudomonas aeruginosa and Staphylococcus aureus ) which Showed dermal infection in experimental animals after 48 hours of exposure to these Microorganisms. Results revealed that ozone has the power to accelerated the healing process depending on the perfect concentration of ozonated water used and the severity of infection & nature of causative agent , in which the recovering period was 7 days for the infection caused by P. aeruginosa and 5 day for S.aureus by using the concentration 60 µg/ml . Results also indicated in this study the stimulated effect of O

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 30 2017
Journal Name
International Journal Of Science And Research
Measurements of X-Ray Dose Delivered at Different Depths Applied on Water Phantom
...Show More Authors

Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1

... Show More
Publication Date
Wed Apr 15 2026
Journal Name
Experimental And Theoretical Nanotechnology
Remote sensing analysis: A decade of water surface changes in Lake Hamrin, Iraq
...Show More Authors

The study of Lake Hamrin is of enormous importance in understanding changes in water levels and their impact on the local environment. It helps to clarify the role of climatic and human factors in the decline of its water resources from 2013 to 2023 in order to ensure sustainable solutions. Satellite imagery from Landsat 8 is used, and processing is performed using ArcGIS Pro and ENVI. The normalized vegetation index (NDVI) is applied to show the changes in the vegetation cover and reveal the amount of change in the surface water area of the lake. It is noted that the water area changes in one year as it increases in the rainy season and decreases in the summer, and it also varies from one year to another with the difference in the amount o

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Mar 27 2023
Journal Name
Aip Conference Proceedings
Stability of Kongele earth dam against rapid drawdown of water from reservoir
...Show More Authors

ABSTRACT In dam construction stages when an earth embankment has retained a reservoir with constant water surface elevation for a long time, seepage conditions within the embankment will be reach a steady state. If it is necessary to drain the reservoir quickly, the pore-water pressures in the embankment may remain relatively high while the stabling effect of the reservoir's weight along the upstream (U/S) side for the embankment has removed. This process is referring to as "Rapid Drawdown" and may be cause instability in the upstream (U/S) face of the embankment. Kongele dam is one of the proposed earth dams to be implement within the current plan in Iraq. The authors study pore water pressure and the effect of rapid drawdown for the dam d

... Show More
View Publication Preview PDF