Water is an essential aspect of life and important in evolution. Recently the potable water quality topic has received much attention. The study aims to determine drinking water quality in Al-Najaf City by collecting samples throughout Al-Najaf city and comparing the results with the Iraqi guidelines (IQS 417) and World Health Organization (WHO) guidelines, as well as to calculate the WQI. Samples were tested in the laboratory between December 2021 and June 2022. The results showed that multiple parameters exceeded the allowable limits during both testing periods; during winter months, the results of TDS and turbidity exceeded the upper limits in multiple locations. Total hardness values also exceeded the limit of 500 ppm for all samples taken in the winter period. For magnesium and calcium, summer measurements were mainly within limits, unlike winter period measurements which mostly exceeded the limits. Residual chlorine tests in winter had higher concentrations, generally ranging from 0.25 to 0.8 mg/l. While During summer, concentrations dropped below the allowable limit in multiple sampling points. The study concluded that the majority of the water samples gathered during the winter months were of poor quality as the total WQI values were between (99-110), While the total WQI values for water samples collected during the summer period were rated as good quality water ranged between (75-81).
In the current study, remote sensing techniques and geographic information systems were used to detect changes in land use / land cover (LULC) in the city of Al Hillah, central Iraq for the period from 1990 - 2022. Landsat 5 TM and Landsat 8 OLI visualizations, correction and georeferencing of satellite visuals were used. And then make the necessary classifications to show the changes in LULC in the city of Al Hillah. Through the study, the results showed that there is a clear expansion in the urban area from 20.5 km2 in 1990 to about 57 km2 in 2022. On the other hand, the results showed that there is a slight increase in agricultural areas and water. While the arid (empty) area decreased from 168.7 km 2 to 122 km 2 in 2022. Long-term ur
... Show MoreThe application of ultrafiltration (UF) and nanofiltration (NF) processes in the handling of raw produced water have been investigated in the present study. Experiments of both ultrafiltration and nanofiltration processes are performed in a laboratory unit, which is operated in a cross-flow pattern. Various types of hollow fiber membranes were utilized in this study such as poly vinyl chloride (PVC) UF membrane, two different polyether sulfone (PES) NF membranes, and poly phenyl sulfone PPSU NF membrane. It was found that the turbidity of the treated water is higher than 95 % by using UF and NF membranes. The chemical oxygen demand COD (160 mg/l) and Oil content (26.8 mg/l) were found after treatment according to the allowable limits set
... Show MoreThis study aims to predict the organic pollution produced from the presence of some polycyclic aromatic hydrocarbons (PAHs) and determination it's concentrations (µg/L , ppb) in Tigris river water by a collection twenty-seven water samples from a selected three stations with nine sampling sites and three depths of water (5 cm , 2 m and 4 m) each site for 4.6 km distance of a geographic studied area which is located between the ( Al-Senak and AL-Sarrafiah bridges ) at Baghdad city – Iraq on May, 2012. The geographic location was determined with a Global Positioning System (GPS) and Geographic Information System (GIS) software program. The concentrations of fourteen components (PAHs) were performed using the reverse phase
... Show MoreThe principal forms of radiation dosage for humans from spontaneous radiation material are being recognized as radon and its progenitors in the interior environment. Radiation-related health risks are caused by radon in water supply, which can be inhaled or ingested. Materials and Methods: The solid-state CR-39 nuclear trace detectors method was using in this research for measuring accumulation of radioactivity in water supply in different locations of Iraq's southwest corner of Baghdad. In Baghdad district, 42 samples were selected from 14 regions (3 samples out of each region) and put in dosimeters for 50 days. Results: The mean radon concentration was 49.75 Bq/m3, that is lower than the internationally recognized limit of 1100 Bq /m3. Th
... Show MoreObjectives: The study aims to assess the nutritional status, identify nutrition-related health problems and
find out the relationships between nutritional status and demographic characteristics of the pregnant
adolescents in Baghdad City.
Methodology: A descriptive study was carried out from April/20/2009 to June/30/2009 through a "Nonprobability"
purposive sample of (196) pregnant adolescents their age between (13–19) years who attend (14)
primary health care centers in Baghdad City seeking for antenatal care. The data were collected by the
investigator who interviewed the pregnant adolescents and filled out the constructed questionnaire formats
which designed for the purpose of the study. Internal consistency of
Objective(s):To evaluate the quality of life among secondary and to find out the relationship between students'quality of life and their socio-demographic characteristics of age, gender, residence, marital status, father's and mother's education, and family financial status in Kirkuk City. Methodology: A cross-sectional study is conducted on (100) studentwho are boys and girls aged(13 to 24) years old. These subjects are studying at secondary schools in Kirkuk City.The study is carried out at secondary schools in Kirkuk City from 7th July 7th 2014 to May 7th 2015. A questionnaire is constructed for the purpose
Abstract
The removal of water turbidity by using crumb rubber filter was investigated .The present study was conducted to evaluate the effect of variation of influent water turbidity (10, 25 and 50 NTU), media size (0.6and 1.14mm), filtration rate (25, 45 and 65 l/hr) and bed depth (30 and 60 cm) on the performance of mono crumb rubber filter in response to the effluent filtered water turbidity and head loss development, and compare it with that of conventional sand filter.Results revealed that 25 l/hr flow rate and 25 NTU influent turbidity were the best operating conditions. smaller media size and higher bed depth gave the best removal efficiency while higher media size and small bed depth gave lower head
... Show MoreThis research was aimed to study the efficiency of microfiltration membranes for the treatment of oily wastewater and the factors affecting the performance of the microfiltration membranes experimental work were includes operating the microfiltration process using polypropylene membrane (1 micron) and ceramic membrane (0.5 micron) constructed as candle; two methods of operation were examined: dead end and cross flow. The oil emulsion was prepared using two types of oils: vegetable oil and motor oil (classic oil 20W-50). The operating parameters studied are: feed oil concentration 50 – 800 mg/l, feed flow rate 10 – 40 l/h, and temperature 30 – 50 oC, for dead end and cross flow microfiltration.
It was found that water flux decrea
In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show More