A fixed firefighting system is a key component of fire safeguarding and reducing fire danger. It is installed as a permanent component in a structure to protect the entire or a portion of the building and its contents. The study aims to review the previous studies that deal with the evaluation of fire safety measures and their use in resolving problems associated with fire threats in buildings. For this reason, a number of previous studies in this field were reviewed compared with the NFPA code. The findings revealed that regulatory developments over the last several decades had created an atmosphere conducive to innovation. This has resulted in a growth in the number of fixed firefighting system types now obtainable. These solutions provide substantial distinction in terms of performance and hence safety. Not only is the availability of different fire risk alleviation systems important, but so is the election of the most convenient solution for the job. This is typically seen inside regulatory procedures and basics of thumb or heuristics and depends on the knowledge and expertise of divergent specialists. When several perceived danger and results thresholds are surpassed, fixed firefighting systems are frequently included as extra fire protection and resilience measures
The nation-building process in fragile states is complex, often involving multifaceted challenges and opportunities. A pertinent example is Iraq post-2003, which serves as a model to study the intricacies of rebuilding a nation in the aftermath of conflict. During this period, we witnessed a significant international intervention aimed at establishing democratic governance, fostering economic development, and restoring social stability. Iraq’s nation-building journey showcases both successes and shortcomings. Establishing a representative government marked a step towards inclusivity and political participation, yet sectarian tensions persisted, hindering cohesive national identity. Economic initiatives aimed to harness Iraq's oil resou
... Show MoreThe research aims to build a training program to develop the willpower in the kindergarten children. In order to achieve the objective of the research, the two researchers have developed a Training Program according to the following steps:
- Determining the general objective of the Training Program.
- Determining the behavioral objectives of the Training Program.
- Determining the content of the Training Program.
- Implementing the content of the Training Program sessions.
- Evaluating the Training Program.
The training program consisted of (15) sessions, each session included a set of parts (title, general objective, methods, time and place to implement the sessions, behavioral goals, tool
... Show MoreThe subject of marketing culture and mental image is one of the important topics in the field of management. There is no study that combines these two variables. The research is important because of the increasing importance of the subject. The future direction of the company in question will support the company's economic and marketing responsibilities. And reflect the company's mental image, as a culture that contributes to changing the reality of the organization investigated by polling the views of a sample of managers in the General Company for Vegetable Oil Industry, which (30) out of the (65) individual, and There are two hypotheses of research: There is a significant
... Show MoreA concept of indoor solar illumination is described and simulated. The solar illumination system is composed of a tracking primary reflector, a selective secondary reflector, a visible light guide and a scattering solid glass tube fixture. Each part of the solar illumination system is optically suited and compatible with other parts to realize high efficiency. The simulation is conducted for Baghdad city for a library hall. Two major days over a year are chosen to investigate the illumination system for acceptable visible light level for reading hall. The two days are: summer solstice day and winter solstice day at 8:00 AM and 12:00 PM for each. Research results showed that the design of the solar system is achieved on the base of minimu
... Show MoreExperimental work was carried out to investigate the effect of fire flame (high temperature) on specimens of one way slabs using Self Compacted Concrete (SCC). By using furnace manufactured for this purpose, twenty one reinforced concrete slab specimens were exposed to direct fire flame. All of specimens have the same dimensions. The slab specimens were cooled in two types, gradually by left them in the air and suddenly by using water. After that the specimens were tested under two point loads, to study, the effect of
different: temperature levels (300ºC, 500ºC and 700ºC), and cooling rate (gradually and sudden cooling conditions) on the concrete compressive strength, modulus of rupture, flexural strength and the behavior of reinf
A smart home’s safety is a very urgent question due to several causes. This chapter analyzes current directions of smart house system safety technologies in use nowadays. Current studies are dedicated to the integration of Internet of Things (IoT) into smart home systems; critical situations that may arise; and specifications of sensors in the smart home system. The huge number of connected devices and the capacity embedded within these devices to direct demand resources make deliberate attacks on them and/or inadvertent downfall events such as abrupt bad interactions between connected devices, mechanical failure of devices, and unsuccessful communication may lead to IoT-based systems entering unreliable and threatening physical s
... Show MoreExisting literature suggests that construction worker safety could be optimized using emerging technologies. However, the application of safety technologies in the construction industry is limited. One reason for the constrained adoption of safety technologies is the lack of empirical information for mitigating the risk of a failed adoption. The purpose of this paper is to fill the research gap through identifying key factors that predict successful adoption of safety technologies.
In total, 26 key technology adoption predictors
Antibacterial substances belong to a group of compounds that attack dangerous microorganisms. Therefore, killing bacteria or reducing their metabolic activity will lessen their adverse effects on a biological system. They originated from either synthetic materials, microbes, or mold. Many of these medications treat the gram-negative bacteria from the critical precedence group, such as pseudomonas, carbapenem-resistant acinetobacter, and enterobacterales. This study aims to investigate the simultaneous analysis of specific antibacterial spectrophotometrically. The WHO maintains this list of priority infections with antibiotic resistance. Drug combinations in single dosage forms are becoming increasingly popular in the pharmaceutical industry
... Show More