Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
The objective of this study is to verify the overall performance and evaluate the wastewater quality of the wastewater treatment plant at the Abu Ghraib Dairy Factory and compare the results with the Iraqi Quality Standards (IQS) for effluent disposal and with the national determinants of treated water use. Agricultural irrigation wastewater, which included daily assessment records of the main parameters affecting wastewater [five-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total dissolved solids (T.D.S), total suspended solids (TSS), phosphate (PO4), nitrate (NO3), hydrogen ion concentration (pH)] obtained from the quality control department of Abu Ghraib dairy plant registered from January 2017 to December 2020. Th
... Show MoreAdhrt all fungal biological control ability Tdhadah less than 2 repel Alaftran Almamradan showed leaky mushroom Biological control is thermally laboratories and different concentrations of 5, 10 and 20% inhibition in the growth of fungus colonies amounted to 3.8 cm and 3.1 and 2.4 respectively in comparison with control 9 cm
Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves re
... Show MoreWater injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the
pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves removing the dissolved O2 from w
Monitoring water quality in hemodialysis systems is extremely important to maintain adequate quality services for patients suffering from kidney failure. This work aims to examine and evaluate bacteriological characteristics and endotoxin contamination levels in hemodialysis water produced in dialysis centers. Forty‐eight water samples were collected and analyzed from four major hospitals in Baghdad for one year to evaluate seasonal effects. The analysis included the determination of total heterotrophic bacteria using the pour plate method, identification of bacterial isolate using the Vitek2 compact instrument, and the determination of endotoxins levels using Limulus ameboc
The ceiling of the midbrain has a couple of optic lobes which are prominent and used as an optic center that reflex what it receives from eye retina fibers. The histology of optic tectum has been studied in Iraqi water snake natrix tesselata tesselata . It was found that the number of optic tectum were seven main strata organized from the outside to the inside as follows : the stratum zonula (SZ), the stratum opticum (SO), the stratum fibrosum et griseum superficialis (SFGS), the stratum griseum central (SGC), the stratum album central (SAC), the stratum griseum periventricular (SGP), and the stratum album periventricular (SAP). the three last strata consider deep layers on the optic tectum It was noticed that the thinnest strata was the fi
... Show MoreA simple, rapid, accurate and sensitive spectrophotometric method has been developed for the determing carbamate pesticides in both pure and water samples. The method is appropriate for the determination of carbofuran in the presence of other ingredients that are usually available in dosage forms. The effect of organic solvents on the spectrophotometric properties of the azo dye and the structure of the resulting product have also been worked out and it is found to be 1:1 benzidine :carbofuran. The method can be successfully applied to determination of carbofuran in water samples. The method is based on diazotization of Benzidine (4, 4 – diamino biphenyl) with sodium nitrite and hydrochloric acid followed by coupling with carbofuran
... Show More