Preferred Language
Articles
/
joe-153
Non-Linear Behavior of Strengthened Steel-Concrete Composite Beams with Partial Interaction of Shear Connectors
...Show More Authors

In this research a theoretical study has been carried out on the behavior and strength of simply supported composite beams strengthened by steel cover plate taking into consideration partial interaction of shear connectors and nonlinear behavior of the materials and shear connectors. Following the procedure that already has been adopted by Johnson (1975), the basic differential equations of equilibrium and compatibility were reduced to single differential equation in terms of interface slip between concrete slab and steel beam. Furthermore, in order to consider the nonlinear behavior of steel, concrete and shear connectors, the basic equation was rearranged so that all terms related to materials are isolated in the equation from the main variable (interface slip). The exact solution was obtained by considering appropriate boundary conditions according to load types and location. A computer program has been written using MATLAB R2013a to simplify the process of computation of section properties where the load applied iteratively from zero to ultimate capacity of the beam, and the results are compared with available experimental results which show good agreement.

As the composite section reaches its ultimate capacity in bending and lower flange start yielding due to excessive loading, cover plate are furnished in order to increase load carrying capacity of beam. In the process of strengthening, using of cover plate as a percent of the area of lower flange of steel section equal to 41%, 82% and 164% will increase the beam carrying capacity by 15%, 30% and 43% respectively; also using the same above mentioned area of cover plate will reduce the central deflection by 59%, 72% and 80% respectively.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jul 20 2019
Journal Name
Al-nahrain Journal For Engineering Sciences
Inducing Frictional Force to Enhance the Transient Response in Beams
...Show More Authors

This paper studies the effect of contact areas on the transient response of mechanical structures. Precisely, it investigates replacing the ordinary beam of a structure by two beams of half the thickness, which are joined by bolts. The response of these beams is controlled by adjusting the tightening of the connecting bolts and hence changing the magnitude of the induced frictional force between the two beams which affect the beams damping capacity. A cantilever of two beams joined together by bolts has been investigated numerically and experimentally. The numerical analysis was performed using ANSYS-Workbench version 17.2. A good agreement between the numerical and experimental results has been obtained. In general, results s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Aug 27 2022
Journal Name
Egyptian Journal Of Chemistry
Evaluation of Zinc Chelation Ability for Non-Hydroxamic Organic Moieties
...Show More Authors

View Publication
Scopus (9)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Environmental Processes
Removal of Dyes from Aqueous Solutions using Non-Thermal Plasma
...Show More Authors

View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Sep 16 2020
Journal Name
Al-kindy College Medical Journal
STUDY OF TINEA PEDIS IN DIABETIC VERSUS NON-DIABETIC PATIENTS
...Show More Authors

Background : The aim of this work is to study the clinical features and causative fungi of tinea pedis in diabetic and non-diabetic patients. Result : Tinea pedis was estimated to be the second most common skin disease in the United States, after acne. Up to 15% of the U.S., population may have tinea pedis. Across Europe and East Asia, prevalence rates reach 20 %. Methods: The Complete history taking regarding: age, sex, occupation, residency, history of diabetes and diabetic profile (fasting blood sugar and post prandial).and Clinical examination of the feet Aim of the study : The aim of this work was to study the clinical features and causative fungi of tinea pedis in diabetic and non-diabetic patients Conclusion : Tinea pedis is more

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Effectiveness and safety of non-fixation method in cochlear implantation
...Show More Authors

ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 20 2019
Journal Name
Political Sciences Journal
The American vision of the Non-governmental Organizations in Iraq
...Show More Authors

The American vision of the Non-governmental Organizations in Iraq the topic area of that’s paper dealing with Civil Society as concept and practice, its already consider as Western concept and associated with liberalism and political development, they are many definitions of its but most significantly is all organizations, agencies, trade unions and non-governmental institutions, that’s agencies were established after 2003 and received funds from United States and UN development agencies. The non- governments organizations played a significant role as support and develop many cultural, healthy, educational, and social projects, also that’s organizations try to reduction the effects of terrorists actions especially after ISI

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Control of Non Isothermal CSTR Using Different Controller Strategies
...Show More Authors

In all process industries, the process variables like flow, pressure, level, concentration
and temperature are the main parameters that need to be controlled in both set point
and load changes.
A control system of propylene glycol production in a non isothermal (CSTR) was
developed in this work where the dynamic and control system based on basic mass
and energy balance were carried out.
Inlet concentration and temperature are the two disturbances, while the inlet
volumetric flow rate and the coolant temperature are the two manipulations. The
objective is to maintain constant temperature and concentration within the CSTR.
A dynamic model for non isothermal CSTR is described by a first order plus dead
time (FO

... Show More
View Publication Preview PDF