Preferred Language
Articles
/
joe-1457
A Review in Sustainable Plastic Waste in Concrete
...Show More Authors

Recently times, industrial development has increased, including plastic industries, and since plastic has a very long analytical life, it will cause environmental pollution. Therefore studies have resorted to reusing recycled plastic waste (sustainable plastic) to produce environmentally friendly concrete (green concrete). In this research, some studies were reviewed and then summarized into several things, including the percentage of plastic replacement from the aggregate and the effect of this percentage on the fresh properties of concrete, such as the workability and the effect of plastic waste on the hardening properties of concrete such as dry density, compressive, tensile and flexural strength.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Development of methods of treatment of medical waste in the hospitals of Baghdad health Department / (Rusafa survey)
...Show More Authors

Purpose: To contribute to the development of an appropriate program for the management of medical waste based on clear-cut principles in order to reach the overall goal of improving the public health and environment of the population in our country.

Design / Approach / Introduction: The research is based on the analytical descriptive approach as a method of study in the field of data collection using a check list and analysis of the data through the use of some statistical treatments.

 Results: The need is to establish a medical waste management in hospitals and follow international standards in all stages of waste management from sorting, collection, transportation and treat

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The Use of Tea leaves Wastes to reduce Hexavalent Chromium Concentration in industrial Waste Water by Adsorption
...Show More Authors

Abstract : A research was conducted to study the process parameters affecting hexavalent chromium Cr (VI) (carcinogenic compound) the removal percentage from the electrical industries company waste water that contain 88 mg/l of Cr (VI) concentration by adsorption onto tea wastes. Synthetic water with 88 mg/l Cr (VI) concentration was used. Several operation parameters affecting Cr (VI) removal efficiency were investigated, such as pH, initial Cr (VI) concentration, stirring time and tea wastes dose. The experimental results reveal that maximum Cr (VI) removal reached up to 94.26% at pH of 2, stirring time of 180 minute, tea wastes do

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Two Domain Flow Method for Leachate Prediction Through Municipal Solid Waste Layers in Al–Amari Landfill Site
...Show More Authors

Existing leachate models over–or underestimates leachate generation by up to three orders of magnitude. Practical experiments show that channeled flow in waste leads to rapid discharge of large leachate volumes and heterogeneous moisture distribution. In order to more accurately predict leachate generation, leachate models must be improved. To predict moisture movement through waste, the two–domain PREFLO, are tested. Experimental waste and leachate flow values are compared with model predictions. When calibrated with experimental parameters, the PREFLO provides estimates of breakthrough time. In the short term, field capacity has to be reduced to 0.12 and effective storage and hydraulic conductivity of the waste must be increased to

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 30 2025
Journal Name
Gsc Advanced Research And Reviews
A comprehensive review of metal-organic framework based biosensors for detection of reactive oxygen species and hydrogen peroxide in biomedical applications
...Show More Authors

Metal-organic frameworks (MOFs) have emerged as revolutionary materials for developing advanced biosensors, especially for detecting reactive oxygen species (ROS) and hydrogen peroxide (H₂O₂) in biomedical applications. This comprehensive review explores the current state-of-the-art in MOF-based biosensors, covering fundamental principles, design strategies, performance features, and clinical uses. MOFs offer unique benefits, including exceptional porosity (up to 10,400 m²/g), tunable structures, biocompatibility, and natural enzyme-mimicking properties, making them ideal platforms for sensitive and selective detection of ROS and H₂O₂. Recent advances have shown significant improvements in detection capabilities, with limit

... Show More
View Publication
Crossref
Publication Date
Thu Dec 31 2020
Journal Name
Journal Of New Theory
Brief review of soft sets and its application in coding theory
...Show More Authors

In this paper, we will focus to one of the recent applications of PU-algebras in the coding theory, namely the construction of codes by soft sets PU-valued functions. First, we shall introduce the notion of soft sets PU-valued functions on PU-algebra and investigate some of its related properties.Moreover, the codes generated by a soft sets PU-valued function are constructed and several examples are given. Furthermore, example with graphs of binary block code constructed from a soft sets PU-valued function is constructed.

Publication Date
Sat Mar 23 2024
Journal Name
Journal Of Optics
Review Recent Developments In High-Power Diode Lasers For Biomedical Applications
...Show More Authors

Diode laser technology is well established for biomedicine applications which demand high-power pulse-wave. They are extensively utilized from medical imaging and testing to surgical therapies and the latest aesthetic processes. For medical therapeutic practices, diode lasers have become the ideal laser source for this particular purpose. In the last previous years, semiconductor laser technology has evolved to produce high-repetitions rate near-infrared pulsed lasers diodes that are dependable, low-cost, portable, and small-weight, about few grams. In this paper, we review the recent development and demonstration of diode laser devices for biomedical applications recorded in the latest years taking into account the power, wavelength, and p

... Show More
Scopus (3)
Scopus
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Coloproctology
Rectal cancer and chemoradiation in Iraq: systematic review and meta-analysis
...Show More Authors
Abstract<p> Background Rectal cancer is one of the most common malignant tumors of gastrointestinal tract. Combining chemotherapy with radiotherapy has a sound effect on its management.</p><p> Objectives Assessment the patterns of characterizations of rectal cancer. Evaluation of the efficacy, and long-term survival of pre-/ postoperative chemoradiation. Collecting all eligible evidence articles and summarize the results.</p><p> Methods By this systematic review and meta-analysis study, we include data of chemoradiation of rectal cancer articles from 2015 until 2019. The research was carried out at Baghdad Medical City oncology centers. Accordance with the</p> ... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Swarm And Evolutionary Computation
Algorithmic design issues in adaptive differential evolution schemes: Review and taxonomy
...Show More Authors

View Publication
Scopus (210)
Crossref (197)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Investigating the elastic and plastic behavior of I-steel beams by using carbon fiber laminates
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Aug 22 2019
Journal Name
Al-khwarizmi Engineering Journal
Optimizing the Parameters of Hot-wire CNC Machine to Enhance the Cutting of Plastic Foam
...Show More Authors

     Hot-wire cutting is one of the important, non-traditional thermomechanical way to cut polymer, usually expanded foam and extruded foam, in low volume manufacturing. The study and analysis of Hot-Wire cutting parameters play an important role to enhance the quality and accuracy of the process and products. The effects on the surface have been investigated by using experimental tests designed according to the Taguchi orthogonal array (OA). In this study, four parameters with five levels for each parameter have been used: [temperature of wire (A) (100, 120, 130, 150, 160) °C], [diameter of wire (B) (0.3,0.4,0.5,0.7,0.8) mm], [velocity of cutting (C) (200, 300,400,500,600) mm/min], [and density of foam (D) (0.01,0.0

... Show More
View Publication Preview PDF