This research analyzes the level of the short circuit effect of the Iraqi super network and decides the suitable location for the High Voltage Direct Current (HVDC) connections in order to obtain the best short circuit reduction of the total currents of the buses in the network. The proposed method depends on choosing the transmission lines for Alternating current (AC) system that suffers from high Short Circuit Levels (SCLs) in order to reduce its impact on the transmission system and on the lines adjacent to it and this after replacing the alternating current (AC) line by direct current (DC) line. In this paper, Power System Simulator for Engineering (PSS/E) is used to model two types of HVDC lines in an effective region of Iraqi networks and to perform comparative studies to test the location of Short Circuit Levels (SCLs) between an actual AC and AC/DC case study in a portion of the Iraqi national network. The results proved the effectiveness of this method in eliminating severe faults and unwanted short currents, and the results showed that the bipolar type is better in reducing Short Circuit Levels of the Iraqi network.
This study, which was conducted in the city of Mosul, through collected 1200 samples from the stool of patients with diarrhea attending hospitals and private clinics for the period from the beginning of January 2019 to the end of December 2019, those whose ages ranged from less than a year-60 year, and for both sexes and by reality 700 samples stool for males and 500 samples stool for females. Samples were collected in clean, sterile, and sealed 40ml plastic bottles. Patient information is noted, name of the parasite, history, sex, age, address. The result showed that climate and temperature have a significant effect on increase the incidence of intestinal parasites through the direct effect on the increase in infection rate. This effect wa
... Show MoreElectrochemical decolorization of direct black textile dye was studied in the presence of sodiumhydroxide (NaCl). Electrochemical cell occupy about 1 liter of working electrolyte supplied with graphiteelectrodes for both anode and cathode was constructed for this purpose. Decolorization percent, treatment time, power consumption, and pH were studied as a function of the applied voltage and salt concentration. Results show that decolorization increase with increasing salt concentration and applied voltage. Best decolorization of 86% can be achieved after 17 min at 7 volt and 5 g/l salt concentration. Further decolorization can be achieved but this will be accompanied with a sharp increase in power consumption. No significant decrease
... Show MoreImproving the accuracy of load-deformation behavior, failure mode, and ultimate load capacity for reinforced concrete members subjected to in-plane loadings such as corbels, wall to foundation connections and panels need shear strength behavior to be included. Shear design in reinforced concrete structures depends on crack width, crack slippage and roughness of the surface of cracks.
This paper illustrates results of an experimental investigation conducted to investigate the direct shear strength of fiber normal strength concrete (NSC) and reactive powder concrete (RPC). The tests were performed along a pre-selected shear plane in concrete members named push-off specimens. The effectiveness of concrete compressiv
... Show MoreA survey conducted at Dalmaj marsh, Al-Diwaniya Province during 2013 revealed that the marsh encounters a considerable part of the Iraqi vertebrate fauna including 147 species belonging to five classes; Pisces, Amphibia, Reptilia, Aves and Mammalia. Some species are of globally conservation importance. The present results are discussed with the pertinent literature.
Cooling towers is one of the most important unit in industry, they are used to dispose heat from cooling media used in the integrated units. The choice of the cooling media plays recently an important rule due to fresh-water scarcity. The use of saline as a cooling media become of growing interest, but the corrosion problem has to be taken in consideration. In this study the simultaneous effect of cooling tower operation parameters on the corrosion rate of mild-steel is considered. The role of NaCl content is found to be pronounced more than the working solution temperature and flowrate. The corrosion of mild-steel in these studied factors had shown an interesting result especially with the NaCl% content. Firstly, there was an increase in t
... Show MoreThe aim of this paper is to present a method for solving high order ordinary differential equations with two point's boundary condition, we propose semi-analytic technique using two-point oscillatory interpolation to construct polynomial solution. The original problem is concerned using two-point oscillatory interpolation with the fit equal numbers of derivatives at the end points of an interval [0 , 1] . Also, many examples are presented to demonstrate the applicability, accuracy and efficiency of the method by comparing with conventional methods.
هدف البحث الى اعداد تمرينات super site)) للاعبي الريشة الطائرة فئة الشباب ، ومعرفة تأثير التمرينات على بعض المؤشرات الفسيولوجية ومهارة الضربة الساحقة لدى لاعبي الريشة الطائرة فئة الشباب ، وتم تحديد مجتمع البحث من لاعبي الريشة الطائرة فئة الشباب لنادي الارمني وتم اختيار عينة البحث بالطريقة العمدية (8) لاعبين بالريشة الطائرة من النادي الارمني واستخدمت الباحثتان المنهج التجريبي ذو الاختبار القبلي والبعدي .ويهدف ال
... Show MoreThis study aims to identify the role of forensic accounting in the Iraqi environment, banking stability, and to achieve this goal, we used the field survey method, as it is the most appropriate for studying the phenomenon in question and achieving its objectives.
Where we selected a sample consisting of (50) male and female employees, distributed among five private banks in Baghdad governorate, namely (Ashur International Bank, Development Investment Bank, Iraqi Middle East Investment Bank, Hammurabi Commercial Bank, Khaleej Commercial Bank), and the questionnaire tool was applied to them Designed for this purpose, which consisted of
... Show MoreAccurate calculation of transient overvoltages and dielectric stresses from fast-front excitations is required to obtain an optimal dielectric design of power components subjected to these conditions, which are commonly due to switching and lightning, as well as utilization of power-electronic devices. Toroidal transformers are generally used at the low voltage level. However, recent investigations and developments have explored their use at the medium voltage level. This paper analyzes the model-based improvement of the insulation design of medium voltage toroidal transformers. Lumped and distributed parameter models are used and compared to predict the transient response and dielectric stress along the transformer winding. The parameters
... Show More