Preferred Language
Articles
/
joe-1414
Critical Evaluation for Grading and Fineness Modulus of Concrete Sands used in Sulaymaniyah City-Iraq
...Show More Authors

Fine aggregates used for concrete works in Sulaymaniyah city frequently fail to meet the standard requirements for gradation and fineness modulus in cement concrete. This paper aims to critically evaluate gradation, fineness modulus, and clay contents of various natural sands produced and used for concrete work in the region.  Sixteen field sand samples were collected from various sites in Darbandikhan (5 samples), Qalat Dizah (5 samples), Koysinjaq (5 samples), and Piramagroon (1 sample) confirming to ASTM D75. The field samples were parted into test specimens based on ASTM C702. Then, sieve analysis was carried out on the oven-dry test specimens in compliance with ASTM C136. The test results of fine aggregates were compared with American, British, and Iraqi specification standards using ASTM C33, BS 882, and IQS No. 45. It was revealed that only three sands satisfy the ASTM gradation limits while others do not comply and are on the coarser side. Also, eight samples meet the requirements recommended by BS 882, whereas five samples meet limits by IQS No. 45. It was found that only three sands have the fineness modulus within the ranges recommended by ACI 211.1 and ACI 211.4, while the others have high values. Furthermore, it was found that all sands include an allowable amount of finer particles passing sieve size 0.075 mm. In order to improve particle size distributions, it is recommended to use the blending method to obtain a suitable fine aggregate from two or more failed sands.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Iop
Evaluating the part of historical center in Baghdad City
...Show More Authors

Evaluating the part of historical center in Baghdad City

Scopus (6)
Scopus
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Engineering
Traffic Noise in Arterial Streets: Case of Kirkuk City
...Show More Authors

Loud noise can be extremely harmful to the auditory system as well as to human health. Noise pollution is primarily caused by traffic noise. The study's goal was to determine how various vehicle types and speeds affected the amount of noise generated by traffic. The two factors were investigated at seven different arterial streets throughout Kirkuk city to measure the noise levels. The measurements were performed during peak hours to compare the result with WHO standards for noise specification. Traffic volume and vehicle speed are shown to be the key elements that determine an increase in noise level. 

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
The Role of Informational Environment in Building Smart City
...Show More Authors

The research addresses smart city concept as it is the latest urban design trends, by the investment of the capabilities of human, and artificial intelligence for the sake of the advancement of the city. The concept of a smart city is described as one of the most important manifestations of the information revolution, with the end of the twentieth, and the beginning of twenty – first century, The research attributes the emergence of the concept to: deficiencies of means, and traditional methods in building and development of cities, as well as The significant increase in the number of city and global metropolises dwellers. So, smart city approach has been adopted, along with innovative principles and methods which cons

... Show More
View Publication Preview PDF
Publication Date
Wed May 29 2019
Journal Name
Journal Of Planner And Development
Elements of Public Transportation Systems Operating in City Center
...Show More Authors

The traffic congestion caused by the increase in the number of vehicles in the cities as a result of the increase in the population and the density of construction requires the provision of appropriate infrastructure and the provision of transport systems and logistics services that meet the needs of the population to meet the many challenges now and in the future by introducing various modes of transport , In accordance with integrated plans such as the use of (pedestrian friendly environments, bicycles and their own paths, light rail, metro, express bus, as well as public transport buses and others), through the development of Projects High-level roads, such as the annual and major roads, etc., and integrated with the urban planning of

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering Science And Technology
CORROSION of STEEL REINFORCEMENT in INTERNALLY CURED SELF-COMPACTING CONCRETE USING WASTE BRICK and THERMOSTONE
...Show More Authors

Internal curing is a method that has been advised to decrease the primary age cracking, mainly of concrete mixes using low (water to cementitious materials - w/cm) ratios corresponding to the self-compacting concrete-(SCC). This research aims to study the effect of the internal curing using saturated lightweight aggregate- (LWA) on the steel reinforcing corrosion in SCC. In this research, crushed bricks or thermostone were partially replaced by (20%) by the weight of sand and volumetrically measured. The results showed that the steel reinforcement of internally cured concrete showed a slight increase in corrosion up to 300 days of exposure to the saline solution (containing 3.5% NaCl). The ability of using the crushed bricks or thermostone

... Show More
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering Science And Technology
CORROSION of STEEL REINFORCEMENT in INTERNALLY CURED SELF-COMPACTING CONCRETE USING WASTE BRICK and THERMOSTONE
...Show More Authors

Internal curing is a method that has been advised to decrease the primary age cracking, mainly of concrete mixes using low (water to cementitious materials - w/cm) ratios corresponding to the self-compacting concrete-(SCC). This research aims to study the effect of the internal curing using saturated lightweight aggregate- (LWA) on the steel reinforcing corrosion in SCC. In this research, crushed bricks or thermostone were partially replaced by (20%) by the weight of sand and volumetrically measured. The results showed that the steel reinforcement of internally cured concrete showed a slight increase in corrosion up to 300 days of exposure to the saline solution (containing 3.5% NaCl). The ability of using the crushed bricks or thermostone

... Show More
Scopus (3)
Scopus
Publication Date
Thu Aug 01 2019
Journal Name
The Journal Of Solid Waste Technology And Management
Recycling of Waste Compact Discs in Concrete Mix: Lab Investigations and Artificial Neural Networks Modeling
...Show More Authors

This study aimed to investigate the incorporation of recycled waste compact discs (WCDs) powder in concrete mixes to replace the fine aggregate by 5%, 10%, 15% and 20%. Compared to the reference concrete mix, results revealed that using WCDs powder in concrete mixes improved the workability and the dry density. The results demonstrated that the compressive, flexural, and split tensile strengths values for the WCDs-modified concrete mixes showed tendency to increase above the reference mix. However, at 28 days curing age, the strengths values for WCDs-modified concrete mixes were comparable to those for the reference mix. The leaching test revealed that none of the WCDs constituents was detected in the leachant after 180 days. The

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Engineering
Experimental Investigation of Crack Initiation and Growth in Concrete Slabs Placed Directly on Clayey Soil
...Show More Authors

The main objective of this study is to examine the impact of moisture concrete of clayey soil on the concrete slabs placed directly over it. This experimental study presents the mechanical properties of the concrete slab when placed on different clayey soil moisture content ranging from 0% to the optimum moisture content of 35%. The tests were performed on soil concrete specimens of 25*30*50 mm exposed to sprayed water curing conditions for 28 days. Tests of compressive strength, ultrasonic pulse velocity, crack depth and crack width were investigated through this paper. An ejection relationship between compressive strength of concrete and water content in the soil was observed, with a 26% increase with water increasing from 0% to 35%. T

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 10 2018
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
TWO NEW RECORDS OF DWARF SNAKES OF THE GENUS EIRENIS JAN, (REPTTILIA, COLUBRIDAE) IN IRAQI KURDISTAN (NORTH AND NORTHEASTERN OF IRAQ) WITH ANNOTATED CHECKLIST, FOR THE GENUS EIRENIS IN IRAQ
...Show More Authors

    Two dwarf snakes were discovered, Eirenis thospitis Schmidtler & Lanza from Sereen mountain, north east of Arbil  and E. rothii Jan from Saffin mountain North of Arbil  city  North of Iraqi Kurdistan. Supported by description and important notes on variation. In addition summarized list for 9 species of the genus Eirenis Jan in Iraq is also presented.  

View Publication Preview PDF
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Ocular Pharmacology And Therapeutics
Formulation and<i>In Vitro</i>Evaluation of Cyclosporine-A Inserts Prepared Using Hydroxypropyl Methylcellulose for Treating Dry Eye Disease
...Show More Authors

View Publication
Scopus (27)
Crossref (21)
Scopus Clarivate Crossref