Fine aggregates used for concrete works in Sulaymaniyah city frequently fail to meet the standard requirements for gradation and fineness modulus in cement concrete. This paper aims to critically evaluate gradation, fineness modulus, and clay contents of various natural sands produced and used for concrete work in the region. Sixteen field sand samples were collected from various sites in Darbandikhan (5 samples), Qalat Dizah (5 samples), Koysinjaq (5 samples), and Piramagroon (1 sample) confirming to ASTM D75. The field samples were parted into test specimens based on ASTM C702. Then, sieve analysis was carried out on the oven-dry test specimens in compliance with ASTM C136. The test results of fine aggregates were compared with American, British, and Iraqi specification standards using ASTM C33, BS 882, and IQS No. 45. It was revealed that only three sands satisfy the ASTM gradation limits while others do not comply and are on the coarser side. Also, eight samples meet the requirements recommended by BS 882, whereas five samples meet limits by IQS No. 45. It was found that only three sands have the fineness modulus within the ranges recommended by ACI 211.1 and ACI 211.4, while the others have high values. Furthermore, it was found that all sands include an allowable amount of finer particles passing sieve size 0.075 mm. In order to improve particle size distributions, it is recommended to use the blending method to obtain a suitable fine aggregate from two or more failed sands.
Objectives: to determine the effectiveness of an Education Program on Nurses' Knowledge regarding management of extravasation vesicant intravenous chemotherapy
Methodology: quiz-experimental study (single-group pretest-posttest1 and posttest2) was directed in Amal oncology center and national oncology center in Baghdad city from 13th, December 2018 to the 7 of February 2019. The program and tool have been created by the researcher for the purpose of the study. A non- probability purposive sample of (40) nurses who employed in Baghdad oncology centers. Validity and reliability of the instrument were determined through a pilot study. Data were analyzed through the use of Statistical Pack
... Show MoreAbstract Iraq has an important place in the regional and international balance, and the competition among countries has increased in rapprochement with Iraq, not only for its geography or its privileged location, but because it has many other components that make regional and international countries want to strengthen their relations with it (Regional and international powers). In addition to that, Iraq has become increasingly important for these international and regional powers after its victory over the terrorist organization (ISIS), which proved an important fact that Iraq represents the most important pillars in the international balance.
In this study, an experimental investigation had conducted for six high strength laced reinforced concrete one-way slabs to discover the behavior of laced structural members after being exposed to fire flame (high temperature). Self-compacted concrete (SCC) had used to achieve easy casting and high strength concrete. All the adopted specimens were identical in their compressive strength of ( , geometric layout 2000 750 150 mm and reinforcement specifics except those of lacing steel content, three ratios of laced steel reinforcement of (0.0021, 0.0040 and 0.0060) were adopted. Three specimens were fired with a steady state temperature of for two hours duration and then after the specimens were cooled suddenly by spraying water. The
... Show MoreSteel–concrete–steel (SCS) structural systems have economic and structural advantages over traditional reinforced concrete; thus, they have been widely used. The performance of concrete made from recycled rubber aggregate from scrap tires has been evaluated since the early 1990s. The use of rubberized concrete in structural construction remains necessary because of its high impact resistance, increases ductility, and produces a lightweight concrete; therefore, it adds such important properties to SCS members. In this research, the use of different concrete core materials in SCS was examined. Twelve SCS specimens were subjected to push-out monotonic loading for inspecting their mechanical performance. One specimen was constructed from co
... Show MoreIn this study, the effect of fire flame on the punching shear strength of steel fiber reinforced concrete flat plates was experimentally investigated using nine half-scale specimens with dimensions of 1500×1500 mm and a total thickness of 100 mm. The main investigated variables comprised the steel fiber volume fraction 0, 1, and 1.5% and the burning steady state temperature 500 and 600 °C. The specimens were divided into three groups, each group consists of three specimens. The specimens in the first group were tested with no fire effect to be the reference specimens, while the others of the second and third groups were tested after being exposed to fire-flame effect. The adopted characteristics of the fire test were; (one hour) b
... Show MoreFiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and
Experimental work was carried out to investigate the effect of fire flame (high temperature) on specimens of one way slabs using Self Compacted Concrete (SCC). By using furnace manufactured for this purpose, twenty one reinforced concrete slab specimens were exposed to direct fire flame. All of specimens have the same dimensions. The slab specimens were cooled in two types, gradually by left them in the air and suddenly by using water. After that the specimens were tested under two point loads, to study, the effect of
different: temperature levels (300ºC, 500ºC and 700ºC), and cooling rate (gradually and sudden cooling conditions) on the concrete compressive strength, modulus of rupture, flexural strength and the behavior of reinf