Experimental measurements were done for characterizing current-voltage and power-voltage of two types of photovoltaic (PV) solar modules; monocrystalline silicon (mc-Si) and copper indium gallium di-selenide (CIGS). The conversion efficiency depends on many factors, such as irradiation and temperature. The assembling measures as a rule cause contrast in electrical boundaries, even in cells of a similar kind. Additionally, if the misfortunes because of cell associations in a module are considered, it is hard to track down two indistinguishable photovoltaic modules. This way, just the I-V, and P-V bends' trial estimation permit knowing the electrical boundaries of a photovoltaic gadget with accuracy. This measure gives extremely significant data to the plan, establishment, and upkeep of PV frameworks. Three methods, simplified explicit, slope, and iterative, are used to compute two solar models' parameters using MATLAB code. The percentage maximum power errors at (600 and 1000) W/m2 for both current-voltage and power-voltage values with the corresponding measured ones using the slope method are 0.5% and 3% for monocrystalline silicon copper indium gallium di-selenide, respectively. The iterative method is 5 % and 10% for monocrystalline silicon and copper indium gallium di-selenide. Finally, for the simplified explicit 8% and 9%, for monocrystalline silicon and copper indium gallium di-selenide, respectively. The slope method gives more close results with the corresponding measured values than the other two methods for the two PV solar modules used. Consequently, the slope method is less influenced by the meteorological condition.
This research dealt with the process of reducing costs through some strategic methods of management accounting targeted cost analysis unassembled and Alkeisen, where he focused this research through his theory on a review of some administrative accounting strategic technologies, while the second practical side through the application of targeted cost analysis unassembled and Alkeisen, acquired Search importance of focusing on the decisions to cut costs, through the use of some administrative accounting strategic methods and this we can unassembled analysis, continuous improvement, and the cost of quality) when applied quality, "in light of this has been reached to a set of conclusions that the most important of the company's relian
... Show MoreOpportunistic fungal infections due to the immune- compromised status of renal transplant patients are related to high rates of morbidity and mortality regardless of their minor incidence. Delayed in identification of invasive fungal infections (IFIs), will lead to delayed treatment and results in high mortality in those populations. The study aimed to assess the frequency of invasive fungal infection in kidney transplant recipients by conventional and molecular methods. This study included 100 kidney transplant recipients (KTR) (75 males, and 25 females), collected from the Centre of Kidney Diseases and Transplantation in the Medical City of Baghdad. Blood samples were collected during the period from June 2018 to April 2019. Twent
... Show MoreThe objective of this study was to investigate and compare among five different methods of contraception including combined oral contraceptive pills (COC), Depot medroxyprogesterone acetate (DMPA), copper Intrauterine contraceptive device (IUCD), vaginal spermicides and male condom used in Hawler City through estimate of their effect, relative failure rate, percentage of use, adherence and compliance and adverse effects of each contraceptive method. In order to reach to these aims, a retrospective study was conducted in Hawler City in Azadi Health Care Center over a period of 6 months from 22th November, 2010 to 15th May, 2011 during which data collection and subjects follow up for 3 months had been achieved. A conv
... Show MoreThe importance of vibrations in rotating rotors in engineering applications has been examined, as has the best approach to interpreting vibration data. The most extensively used analytical approaches for rotating shaft vibration analysis have been investigated. In this research, a detailed study was made of the Rayleigh and Dunkerley methods due to their importance in the special calculations to find the amplitude of vibrations in the rotation system. The multi-node method was used to calculate both Dunkerley's and Rayleigh's methods. An experimental platform was built to study the vibrations that occur in the rotating shafts, and the results were compared with theoretical calculations and with different distances of the bearings. It pro
... Show MoreIt is generally accepted that there are two spectrophotometric techniques for quantifying ceftazidime (CFT) in bulk medications and pharmaceutical formulations. The methods are described as simple, sensitive, selective, accurate and efficient techniques. The first method used an alkaline medium to convert ceftazidime to its diazonium salt, which is then combined with the 1-Naphthol (1-NPT) and 2-Naphthol (2-NPT) reagents. The azo dye that was produced brown and red in color with absorption intensities of ƛmax 585 and 545nm respectively. Beer's law was followed in terms of concentration ranging from (3-40) µg .ml-1 For (CFT-1-NPT) and (CFT-2-NPT), the detection limits were 1.0096 and 0.8017 µg.ml-1, respec
... Show MoreIn this article, the casting method was used to prepare poly(methyl methacrylate)/hydroxyapatite (PMMA/HA) nanocomposite films incorporated with different contents (0.5, 1, and 1.5 wt%) of graphene nanoplatelets (Gnp). The chemical properties and surface morphology of the PMMA/HA blend and PMMA/HA/Gnp nanocomposite were characterized using FTIR, and SEM analysis. Besides, the thermal conductivity, dielectric and electrical properties at (1–107 Hz) of the PMMA/HA blend and PMMA/HA/Gnp composites were investigated. The structural analysis showed that the synthesized composites had a low agglomerated state, with multiple wrinkles of graphene flakes in the PMMA/HA blend. The thermal conductivity was improved by more than 35-fold its value for
... Show MoreAbstract
This paper concerned with study the effect of a graphite micro powder mixed in the kerosene dielectric fluid during powder mixing electric discharge machining (PMEDM) of high carbon high chromium AISI D2 steel. The type of electrode (copper and graphite), the pulse current and the pulse-on time and mixing powder in kerosene dielectric fluid are taken as the process main input parameters. The material removal rate MRR, the tool wear ratio TWR and the work piece surface roughness (SR) are taken as output parameters to measure the process performance. The experiments are planned using response surface methodology (RSM) design procedure. Empirical models are developed for MRR, TWR and SR, using the analysis
... Show MoreFilms of pure Poly (methyl methacrylate) PMMA and Iron chromate doped PMMA have been prepared using casting method. Transmission and absorptance spectra have been recorded in the wavelength range (300-900) nm, in order to calculate, single oscillator energy, dispersion energy proposed by Wemple - DiDomenico model, average oscillator strength, average oscillator wavelength. The refractive index data at infinite wavelength which was found to obey single oscillator model which was found to increase from 2.27-2.56 as the doping percentage increase. The decreasing in the optical energy gap which was found according to Tauc model were (3.74-3.63) eV , is in good agreement with that obtained by wimple-DiDomenico model. The inverse behavior comp
... Show MoreA total of 33 Iraq male positive for Toxoplasmosis and Iraq male negative for Toxoplasmosis (controls) were studies to Evaluation of some biochemical and immunological parameters changes.The parameters included lipid profile such as (Cholesterol(C), Triglycerides(TG), High-Density Lipoprotein (HDL), Low-Density Lipoprotein (LDL) and very Low-Density Lipoprotein (VLDL) and complement component C3 and C4. The results revealed significant decrease in the total cholesterol, Triglycerides, LDL and non-significant in vLDL (129.96±1.63, 130.69± 2.80, 87.19±1.97, 29.24± 0.83 mg/dl respectively) and non-significant increase in HDL(24.22 ±0.62) mg/dl compared with control group(152.07± 1.63, 156.48± 6.55, 99.26 ±1.39, 31.49± 1.30 and 21.31±
... Show More