This study aims at identifying the notion of Post-Occupancy Evaluation (POE) pertinent to the performance of three general hospitals constructed inside the Sulaimani City, tracing the relationship between the quality of the indoor environments and medical staff (doctors and nurses) satisfaction level. Using some indoor environment elements in the right way will positively influence the mood, stress level of the medical staff, and patient recovery as a result. The POE toolkits (AEDET and ASPECT) have been implemented on targeted wards at the selected hospitals. AEDET and ASPECT questionnaires were distributed among 152 medical staff to obtain their perspectives. In total, 112 valid questionnaires were received. The medical staff at tested hospitals were generally satisfied with the quality of newly built hospitals' indoor environment. The results have shown that exploring medical staff experiences can expose factors that affect their satisfaction levels. Also, the findings reveal that the building's physical quality can be vastly related to the fulfillment of the medical staff's satisfaction. Moreover, the findings underline the role of the quality of the indoor environment in increasing medical staff's satisfaction levels, informing design decisions. Additionally, the persuasive associative outcomes have proven that POE (AEDET and ASPECT) will be pertinent as a tool to the building's physical quality.
The city of Samawah is one of the most important cities which emerged in the poverty area within the poverty map produced by the Ministry of Planning, despite being an important provincial centre. Although it has great development potentials, it was neglected for more than 50 years,. This dereliction has caused a series of negative accumulations at the urban levels (environmental, social and economic). Therefore, the basic idea of this research is to detect part of these challenges that are preventing growth and development of the city. The methodology of the research is to extrapolate the reality with the analysis of the results, data and environmental impact assessment of the projec
The city suffers from the weakness of the civil defense to provide services where there are clusters of residential Guy covered services for that requires the study of the geographic distribution of the civil defense centers in Baghdad care great because they take care of Protect the population and their own property and protect state institutions. Through a review of the problems faced it is expected that this study will help decision-makers to take appropriate steps to develop this service core
To find out the impact of maternal risk factors on the outcome of pregnancy in Baghdad city. A descriptive purposive study was carried out on 100 postpartum women who had delivered for 1 hr. to 24 hrs. ago . the study sample was selected from three hospitals in Baghdad city ( Baghdad teaching hospital ,Fatima Al-Zahra'a maternity and pediatric teaching hospital and Al-Yarmook teaching hospital),during the period from 25 Jan. to 25 Feb. 2006. The data were collected through the use of questionnaire format reviewing pregnants' records and personal interview and were analyzed by using descriptive and inferential statistical approaches. The finding revealed that maternal pregnancy complications had weak effects on pregnancy outcome , while mate
... Show MoreObjective: to assess the risk factors of coronary artery disease patients.
Methodology: A non-probability (purposive) sample of (100) patients. The study population consisted of
a sample of adults from both genders whose ages were 30 years and more, and was newly diagnosed as
having CAD by coronary angiography in the cardiac catheterization unit of An Nasiriyah heart center.
Results: The result of the study showed that the most common modifiable risk factors were low HDL-C
levels (58%), smoking (53%), hypertension (46%), diabetes mellitus (34%), obesity (30%), high
triglycerides (19%), hypercholesterolemia (17%), and high LDLC (14%). All these factors were positively
and significantly associated with the development
The challenge to incorporate usability evaluation values and practices into agile development process is not only persisting but also systemic. Notable contributions of researchers have attempted to isolate and close the gaps between both fields, with the aim of developing usable software. Due to the current absence of a reference model that specifies where and how usability activities need to be considered in the agile development process. This paper proposes a model for identifying appropriate usability evaluation methods alongside the agile development process. By using this model, the development team can apply usability evaluations at the right time at the right place to get the necessary feedback from the end-user. Verificatio
... Show MoreLightweight concrete-filled tube (CFST) columns offer numerous benefits, such as reduced weight, enhanced resistance to buckling, improved structural performance, and the ability to endure cyclic loading. This study considered key research on the structural behavior of CFST columns, covering various topics, including lightweight concrete, methods of concrete placement within steel tubes, and CFST columns with and without shear connectors. The literature review reveals that while several researchers have explored the use of shear connectors as a load-transfer mechanism in CFST columns, there is no consensus on the design methodology for connector resistance. Shear connectors signifi
The performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for perform
... Show More