The tremendous benefits of using cellular phones, which began to increase and unprecedented spread worldwide last decade, were accompanied by harmful effects on the environment due to the increase in electromagnetic radiation (EMR) which be emitted from mobile phone towers. This effect on humans, animals, and plants, which is considered a form of environmental pollution, was sensed by developed countries and Environmental protection organizations. These countries have established restrictions and enacted laws to reduce their negative impact on living beings. The field survey included six major hospitals and 38 schools were distributed over the central neighbourhoods in Al-Najaf city. The results showed that power density (PD) measurements for 4 out of 6 hospitals and 27 out of 38 schools were higher than the biological limit (BL) adopted in this article. This limit is considered as an indicator of the onset of a harmful effect on brain and body tissues. The highest value for PD in hospitals was 5.62 mW/m2 recorded in Al-Sadr Teaching Hospital. PD measurements ranged from1.33 from 3.92 mW/m2 in the selected schools where its readings exceeded the BL. When comparing the PD measurements at the selected sites with limits set by the "International Commission on Non-Ionizing Radiation Protection (ICNIRP)" they were less than the recommended limit in those specifications. All values of specific absorption rates (SAR) in W/Kg were below the ICNIRP Guidelines' limit. However, they were above the biological limit for four hospitals and several of the selected schools.
Objectives: The study aims to identify the effects of an educational program on patients’ knowledge about vascular access care and to find out the relationship between patients knowledge scores and their selected demographic variable. &
... Show MoreThis work represents the set of measurements of radon and thoron concentrations levels of soil-gas in Al-Kufa city in Iraq using electric Radon meter (RAD-7). Radon and thoron concentration were measured in soil-gas in 20 location for three depth of (50, 100 and 150) cm.
The results show that the emanation rate of radon and thoron gas varied from location to anther, depending on the geological formation. The Radon concentration in soil has been found to vary from (12775±400) Bq/m3 at 150 cm depth in location (sample K2) to (41.45±17) Bq/m3, for depth 150 cm in location (sample K20). The thoron concentration in soil has been found to vary from (198±8.5) Bq/m3 at 150 cm depth in location samples (K1 & K2) to undetected in the mos
Background: Cigarette smoking is an important risk factor that has a clear strong association with the prevalence and severity of chronic periodontitis (CP). Salivary biochemical parameters may be affected by both smoking and CP together. Materials and methods: Eighty systematically healthy male patients were included in this study. They were grouped based on their periodontal and smoking status. Unstimulated whole saliva (UWS) was collected from all subject. Salivary flow rate (FR) was measured during sample collection. Parameters such as salivary pH, total protein (TP), albumin (Alb), total fucose (TF), protein bound fucose (PBF) and C-reactive protein (CRP) were estimated. Results: Salivary flow rate was not altered regarding to smoking
... Show MoreIn petroleum refineries, cooling towers, steam engines, and vacuum distillation all require a large volume of water. Before being dumped into the water bodies, it is then transported to an industrial water treatment facility. One of the study's objectives is to verify how well different processing units in the industrial wastewater treatment plant at the cycle refinery remove concentrations of chemical and biological oxygen demand (COD) and BOD. Five samples of industrial wastewater were collected before and after each treatment unit and one sample of wastewater was drained as a final product to the Tigris River. Over the summer, the BOD5 values after each processing unit were 180.8, 175.2, 111, 43, and 37 ppm. Winter readings were
... Show MoreThe gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa
Objective: To assess knowledge of pregnant women concerning prenatal care who attend primary health care
center in Baghdad city.
Methodology: A descriptive analytic study carried on (100) pregnant women who attend primary health care
centers in Baghdad city (50) of them from Al- Sheik Omer primary health care center \Resafa sector .and 50 from
Belat Al-Shuhadaa/ Al Karch sector, during the period from April to November 2011. The data were collected
through interview and use questionnaire format. Validity and Reliability of the questionnaire were determined
through panel of experts and pilot study, data were analysed through the application of descriptive statistical
analysis and inferential statistical analysis.
R
In spite of increasing clinical cases which caused by enteroviruses transferred by water and no documents about entericviruses in the Iraqi water standards. The use of coliphages as an indicator of enteroviruses and fecal pollution were suggested two procedures were applied . The first is Two-Step Enrichment Method and the second is Single Agar Layer Method. Both methods gives good results in Identification of coliphages through testing fifty different water samples (Tap water, Surface water and Bottled water) the study shows the presence of coliphages in fourteen samples.
This research aims to know the impact of leadership integrity as explanatory variable including its dimensions (courage, asceticism, justice, rationality, and humanity) on organizational conflict as responding variable. This research depended on the descriptive-constructive approach through the responses of a sample of (79) employees from (Real Estate Office of The State) in Al-Najaf province. The analyzing of the study done by using (Smart PLS) program to calculate (R2, t, p). Many results have been concluded and one of them, there is significant impact correlation of the leadership integrity on organizational conflict. There are many suggestions have been reached depending on the results reached and one of them is the necess
... Show MoreIn this work the corrosion behavior of Al metal was studied by using non- destructive testing (NDT), which is a noninvasive technique for determining the integrity of a material. The ultrasonic waves was used to measure the corrosion which occur by two corrosive medium (0.1N sodium chloride and 0.1N sodium hydroxide) and study the corrosion by weight-loss method and electrochemical method in addition to performance the microscopic inspection for the samples before and after the immersion in the corrosive medium. Corrosion parameters were interpreted in these media which involve corrosion potential (Ecorr) and corrosion current density (icorr). The results indicate that both
... Show More