Preferred Language
Articles
/
joe-121
Ultrasound-Assisted Oxidative Desulfurization of Diesel
...Show More Authors

Due to the dramatic environmental impact of sulfur emissions associated with the exhaust of diesel engines, last environmental regulations for ultra-low-sulfur diesel require a very deep desulfurization (up to 15 ppm), which cannot be met by the conventional hydrodesulfurization units alone. The proposed method involves a batch ultrasound-assisted oxidative desulfurization (UAODS) of a previously hydrotreated diesel (containing 480 ppm sulfur) so as to convert the residual sulfur-bearing compounds into their corresponding highly polar oxides, which can be eliminated easily by extraction with a certain highly polar solvent. The oxidizing system utilized was H2O2 as an oxidant, CH3COOH as a promoter, with FeSO4 as a catalyst; whereas acetonitrile was used as extractant. The major influential parameters related to UAODS process have been investigated, namely: ratio of oxidant/fuel, ratio of the promoter/oxidant, dose of catalyst, reaction temperature, and intensity of ultrasonic waves. Kinetics of the reaction has been also studied; it was observed that the UAODS of diesel fuels fitted pseudo-first-order kinetics under the best experimental conditions, whereas values of the apparent rate constant and activation energy were 0.373 min-1 and 24 KJ/mol, respectively. The oxidation treatment, in combination with ultrasonic irradiation, revealed a synergistic effect for diesel desulfurization. The experimental results showed that sulfur removal efficiency could amount to 98% at mild operating conditions (70 C and 1 bar). This indicates that the process is efficient and promising for the production of ultra-low-sulfur diesel fuels.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorptive Desulfurization of Iraqi Heavy Naphtha Using Different Metals over Nano Y Zeolite on Carbon Nanotube
...Show More Authors

The present research was conducted to reduce the sulfur content of Iraqi heavy naphtha by adsorption using different metals oxides over Y-Zeolite. The Y-Zeolite was synthesized by a sol-gel technique. The average size of zeolite was 92.39 nm, surface area 558 m2/g, and pore volume 0.231 cm3/g. The metals of nickel, zinc, and copper were dispersed by an impregnation method to prepare Ni/HY, Zn/HY, Cu/HY, and Ni + Zn /HY catalysts for desulfurization. The adsorptive desulfurization was carried out in a batch mode at different operating conditions such as mixing time (10,15,30,60, and 600 min) and catalyst dosage (0.2,0.4,0.6,0.8,1, and 1.2 g). The most of the sulfur compounds were removed at 10 min for all catalyst ty

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oxidation desulfurization of model oil using carbon composite derived from peach stone waste
...Show More Authors

     In this study, oxidative desulfurization of dibenzothiophene (DBT) with H2O2 as an oxidant was studied, whereas the catalyst used was zirconium oxide supported on Activated carbon (AC). Zirconium oxide (ZrO2) was impregnated over prepared activated carbon (AC) and characterized by various techniques such as XRD, FTIR, BET, SEM, and EDX. This composite was used as a heterogeneous catalyst for oxidation desulfurization of simulated oil. The results of this study showed that ZrO2/AC composite exhibited significant catalytic activity and stability, effectively lowering sulfur content under mild conditions. Factors such as reaction temperature (30, 40, 50, 60°C), time (5, 10, 15,20,30,60, 80 100 min), catalyst dose (0.3, 0.5,

... Show More
View Publication
Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SPECTROPHTOTOMETRIC DETERMINATION OF PURE SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS BY OXIDATIVE COUPLING REACTION: SPECTROPHTOTOMETRIC DETERMINATION OF PURE SULFAMETHOXAZOLE IN PHARMACEUTICAL PREPARATIONS BY OXIDATIVE COUPLING REACTION
...Show More Authors

            A new, simple, rapid and sensitive spectrophotometric method for the determination of sulfamethoxazole in both pure form and pharmaceutical preparations has been reported.The adapted technique based on utilization 4-aminobenzene sulfonic acid as a new modern chromogenic through an oxidative coupling reaction with sulfamethoxazole and potassium iodate in basic media to form orange soluble dye product with absorption maxima at 490 nm. Subject to Beer's law in the range 2–32μg mL-1. The values of molarabsorption coefficient (ε) and correlation coefficient were found to be 9.118 × 103 and0.9999 respectively whereas the Sandels index was

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Association of Oxidative Stress Markers with Cholelithiasis
...Show More Authors

Oxidative stress markers are of important diagnostic parameters for many disorders including cholelithiasis. This present study has aimed to assess the state of oxidative stress in symptomatic radiographically confirmed (Cholelithiasis) patients by measuring two parameters used as oxidative stress parameters which are serum myeloperoxidase (MPO) and superoxide dismutase (SOD). This study was carried out on 100 patient diagnosed as (Cholelithiasis) patients with 30 age and sex matched healthy controls by measuring serum (MPO) and (SOD) by ELIZA technique .Results showed significantly decrease in antioxidant enzyme(SOD) and increase in serum level of (MPO) comparing with controls.

Keywords: Cholelithiasis , Oxidative stress

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 12 2023
Journal Name
Mustansiriyah Journal Of Pure And Applied Sciences
Cavitation microbubbles in the medical ultrasound imaging: A Review
...Show More Authors

Ultrasound is a mechanical energy which can generate altering zones of compression and rarefaction along its path in the tissues. Ultrasound imaging can provide a real time screening for blood and multiple organs to aiding the diagnostic and treatment. However, ultrasound has the potential to deposit energy in the blood and tissues causing bio effects which is depending on ultrasound characteristics that including frequency and the amount of intensity. These bio effects include either a stable cavitation presented non thermal effects or inertial cavitation of harmful effect on the tissues. The non-thermal cavitation can add features in diagnostic imaging and treatment more than the inertial cavitation. Ultrasound Contrast agents are a micro

... Show More
Publication Date
Mon Aug 18 2025
Journal Name
Journal Of Genetic And Environment Conservation
Ultrasound application as a new green technology for preservation of table eggs: A review
...Show More Authors

In recent years, there has been a significant increase in research demonstrating the new and diverse uses of non-thermal food processing technologies, including more efficient mixing and blending processes, faster energy and mass transfer, lower temperature and selective extraction, reduced thermal and concentration gradients, reduced equipment size, faster response to extraction control, faster start-up, increased production, and a reduction in the number of steps in preparation and processing. Applications of ultrasound technology have indicated that this technology has a promising and significant future in the food industry and preservation, and there is a wide scope for its use due to the higher purity of final products and the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Ultrasound Guided Core Needle Biopsy in The Diagnosis of Suspicious Breast Lesions: Radiologist’s perspectives
...Show More Authors

Background: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.

Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.

Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V.  Ultrasound guided core needle biopsy was performed for each patient. Surgical pathol

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Aip Conference Proceedings
Artificial neural network model for predicting the desulfurization efficiency of Al-Ahdab crude oil
...Show More Authors

View Publication Preview PDF
Scopus (11)
Crossref (10)
Scopus Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
DIESEL PARTICULATE EMISSIONS EVALUATION FOR SINGLE CYLINDER ENGINE FUELLED WITH ETHANOL AND GAS-OIL SOLUTIONS
...Show More Authors

Particulate matter (PM) emitted from diesel engine exhaust have been measured in terms of mass, using
99.98 % pure ethanol blended directly, without additives, with conventional diesel fuel (gas – oil),to
get 10 % , 15 %, 20 % ethanol emulsions . The resulting PM collected has been compared with those
from straight diesel. The engine used is a stationary single cylinder, variable compression ratio Ricardo
E6/US. This engine is fully instrumented and could run as a compression or spark ignition.
Observations showed that particulate matter (PM) emissions decrease with increasing oxygenate
content in the fuel, with some increase of fuel consumption, which is due to the lower heating value of
ethanol. The reduction in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Al-kindy College Medical Journal
Ultrasound of the Rotator Cuff: A Comparison of Ultrasonographic and Physical Examination Finding in SeventyCases
...Show More Authors

Background : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome. Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ultrasonogr

... Show More
View Publication Preview PDF