Visible light communication (VLC) is an upcoming wireless technology for next-generation communication for high-speed data transmission. It has the potential for capacity enhancement due to its characteristic large bandwidth. Concerning signal processing and suitable transceiver design for the VLC application, an amplification-based optical transceiver is proposed in this article. The transmitter consists of a driver and laser diode as the light source, while the receiver contains a photodiode and signal amplifying circuit. The design model is proposed for its simplicity in replacing the trans-impedance and transconductance circuits of the conventional modules by a simple amplification circuit and interface converter. The system was tested at communication distances of 1m and 3.5m using a terminal emulation program for data transfer between two computing devices.
In his post colonial novel, In the Skin of a lion, the Canadian/Sri Lankan writer,
Michael Ondaatje is so interested in the term "Post colonialism" because he wants to show
that the term doesn't only refer to a period of time that comes after colonialism. In other
words, post colonialism is not only referred to as a literal description of formerly colonial
societies. He deals with the termas a literary genre and an academic construct that describes
the global conditions of a man after a period of colonialism. He shows that post colonialism is
a theory that tries to examine and explore the different styles and faces of European authority
to control the colonized. Ondaatje's attempt through such term is to unmask Europ
In this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively
Sequence covering array (SCA) generation is an active research area in recent years. Unlike the sequence-less covering arrays (CA), the order of sequence varies in the test case generation process. This paper reviews the state-of-the-art of the SCA strategies, earlier works reported that finding a minimal size of a test suite is considered as an NP-Hard problem. In addition, most of the existing strategies for SCA generation have a high order of complexity due to the generation of all combinatorial interactions by adopting one-test-at-a-time fashion. Reducing the complexity by adopting one-parameter- at-a-time for SCA generation is a challenging process. In addition, this reduction facilitates the supporting for a higher strength of cove
... Show MoreIn this research, a simple experiment in the field of agriculture was studied, in terms of the effect of out-of-control noise as a result of several reasons, including the effect of environmental conditions on the observations of agricultural experiments, through the use of Discrete Wavelet transformation, specifically (The Coiflets transform of wavelength 1 to 2 and the Daubechies transform of wavelength 2 To 3) based on two levels of transform (J-4) and (J-5), and applying the hard threshold rules, soft and non-negative, and comparing the wavelet transformation methods using real data for an experiment with a size of 26 observations. The application was carried out through a program in the language of MATLAB. The researcher concluded that
... Show MoreDiphenhydramine hydrochloride was determined through a newly developed turbidimetric method on a home-designed continuous-flow injection analysis (CFIA) system. The principle of the method is based on the precipitation-induced signal enhancement, using potassium hexacyanoferrate (III) as a selective precipitating agent. The CFIA manifold uses a flow-through detection cell that consists of 12 white light-emitting diodes and three solar cells placed at 0, 90 and 180 degrees in order to track cumulative light scattering over a range of angles. The systematically optimized chemical and instrumental parameters were the reagent concentration, flow rate and sample volume to attain optimal
