Preferred Language
Articles
/
joe-1121
Load-settlement Behavior of Steel Piles in Different Sandy Soil Configurations
...Show More Authors

In the case where a shallow foundation does not satisfy with design requirements alone, the addition of a pile may be suitable to improve the performance of the foundation design. The lack of in-situ data and the complexity of the issues caused by lagging in the research area of pile foundations are notable. In this study, different types of piles were used under the same geometric conditions to determine the load-settlement relationships with various sandy soil relative densities. The ultimate pile capacity for each selected pile is obtained from a modified California Bearing Ratio (CBR) machine to be suitable for axial pile loading. Based on the results, the values of Qu for close-ended square pile were increased by 15.2, 19.3, and 9.1 % for different pile lengths of 100, 150, and 200 mm in comparison with the H-pile. At the same time, the open-ended square pile had a lower capacity in comparison with closed-ended square pile tested in medium sand. Also, in the dense sand, the values of Qu for close-ended square pile were increased by 49.7, 47.8, and 69.6% for the same pile length in comparison with the H-pile. Notably, sand's density has a significant effect on the ultimate load capacity for different types of piles.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
Mj Journal On Applied Mathematics
Mathematical models for estimation the concentration of heavy metals in soil
...Show More Authors

Publication Date
Fri Jan 01 2016
Journal Name
Lap Lambert Academic Publishing
New Technique to Estimate the concentration of Heavy Metals in soil
...Show More Authors

There are many aims of this book: The first aim is to develop a model equation that describes the spread of contamination through soils which can be used to determine the rate of environmental contamination by estimate the concentration of heavy metals (HMs) in soil. The developed model equation can be considered as a good representation for a problem of environmental contamination. The second aim of this work is to design two feed forward neural networks (FFNN) as an alternative accurate technique to determine the rate of environmental contamination which can be used to solve the model equation. The first network is to simulate the soil parameters which can be used as input data in the second suggested network, while the second network sim

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 21 2018
Journal Name
The Iraqi Geological Journal
GEOCHEMICAL PARTITIONING OF HEAVY METALS IN THE URBAN SOIL, KIRKUK, IRAQ
...Show More Authors

This work focused on anthropogenic influences of the trace metals distribution in the soils of Kirkuk city. Sequential extraction technique was used to determine the distribution of the chemical fractions of Ag, Cd, Co, Cu, Ni, Pb, Zn, As, Cr and V in soil of Kirkuk city. This area is affected mainly by burning oil trash. Results show that these heavy metals were primarily restricted to surface horizons and mostly associated with the residual fraction (28.8 – 50%). The remnant fractions (13.8 – 33.1%) linked to the organic matter, 7.9 – 27.2% was bound to Fe-Mn oxide, 0.7 – 27.9 was bound to carbonate. Only a small amount of the total metals in the soil is exchangeable (0.5 – 4.2%) and water soluble (0 – 4.1%) fractions.

... Show More
View Publication
Scopus (29)
Crossref (1)
Scopus Crossref
Publication Date
Tue Oct 14 2025
Journal Name
Cab Reviews: Perspectives In Agriculture, Veterinary Science, Nutrition And Natural Resources
The role of modern agricultural practices in enhancing soil erosion resistance
...Show More Authors

This review focuses on conservation agriculture (CA) and its effects on increasing the soil’s resistance to erosion. CA involves minimum soil disturbance (minimum tillage/ no-till), diversified crop rotation, and maintenance of the soil cover to increase soil fertility and reduce erosion. CA reduces soil loss by up to 90% and water erosion by approximately 50 to 70% from runoff as it increases the health of the soil, yield of crops, and water-retention capacity of the soil by incorporating soil organic matter and promoting biodiversity. Crop rotation prevents the replenishment and depletion of soil nutrients by atmospheric fixation of nitrogen/biological nitrogen fixation. Controlled traffic farming (CTF) is a new strategy in which travel

... Show More
View Publication
Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effect of Cyanobacteria Isolates on Rice Seeds Germination in Saline Soil
...Show More Authors

Cyanobacteria are prokaryotic photosynthetic communities which are used in biofertilization of many plants especially rice plant. Cyanobacteria play a vital role to increase the plant's ability for salinity tolerance. Salinity is a worldwide problem which affects the growth and productivity of crops. In this work three cyanobacteria strains (Nostoc calcicola, Anabaena variabilis, and Nostoc linkia) were isolated from saline soil at Kafr El-Sheikh Governorate; North Egypt. The propagated cyanobacteria strains were used to withstand salinity of the soil and increase rice plant growth (Giza 178). The length of roots and shoot seedlings was measured for seven and forty days of cultivation, respectively. The results of this investigation showed

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
The Effective Width in Composite Steel Concrete Beams at Ultimate Loads
...Show More Authors

A composite section is made up of a concrete slab attached to a steel beam by means of shear connectors. Under positive and negative bending moment, part of the slab will act as a flange of the beam, resisting the longitudinal compression or tension force. When the spacing between girders becomes large, it is evident that the simple beam theory does not strictly apply because the longitudinal stress in the flange will vary with distance from the girder web, the flange being more highly stressed over the web than in the extremities. This phenomenon is termed "shear lag". In this paper, a nonlinear three-dimensional finite element analysis is employed to evaluate and determine the actual effective slab width of the composite steel-concrete

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The Reflection of self competency of the managers in their behavior
...Show More Authors

Abstract

      This research aims to measure the effect of Self competency of the Managers in their behavior from the view point of the working individual in the organization since the behavior of managers is considered to be one of the essential variables in the organization which can affect the performance and the commitment of the working individual. the questioners was used to gather the data and the Iraqi Rail Road co. was the field of the study . and a random sample of (36) individual of the subordinates of the managers society of the study and used the (SPSS) statistical program was used in the analysis of the data of the research . the findings refer to the existence of a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 17 2022
Journal Name
International Journal Of Health Sciences
Corrosion inhibitor of carbon steel in 3.5%NaCl solution with Schiff base compounds
...Show More Authors

In this work, synthesized N4,N4`-bis(2, 3, 4 nitro benzylidene) biphenyi-4-4`-diamine(B1-B3) , was tested as an inhibitors in controlling the corrosion of carbon steel in NaCl 3.5% solution by using open circuit potential (OCP),at four different temperatures (293, 303, 313 and 323 K). Furthermore, the surface morphology was investigated using the Atomic force microscopy (AFM). The effect of using different Schiff bases and temperature was also investigated. Schiff bases was synthesized and characterized via using. Fourier Transform Infrared Spectroscopy (FT-IR)and Atomic Force Microscope (AFM) characterized . The experimental results shown that Schiff bases can consider as an excellent corrosion inhibitors for carbon steel in NaCl 3

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed Mar 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Corrosion Inhibition for Carbon Steel of Benzimidazole Derivatives Synthesized in Sulfuric Acid Solution
...Show More Authors

Synthesis three organic inhibitors for carbon steel corrosion: 2-(propylthio)-1H-benzo[d]imidazole (PTBI), 2-(allylthio)- 1H-benzo[d]imidazole (ATBI) and 2-(prop-2-ynylthio)-1H-benzo[d]imidazole (YTBI) were prepared from reaction of 2-mercapto benzimidazole with different alkyl halide. The melting point and TLC were used to confirm the purity of the inhibitors as well as using the [FTIR, 1H-NMR and 13C-NMR] for the identify structures. The synthesized inhibitors were examined by potentiostatic polarization measurement as corrosion inhibitors of carbon steel in acidic media [1M H2SO4 ].The polarization measurement results showed that the mixed type inhibitors. In addition, the efficiency of inhibitors (YTBI) were studied at different con

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF