In recent years, there is more interest in water sources availability, including groundwater due to an increase in demand for water because of the increasing population in the world, and the water recedes due to climate change also. Therefore, the study of groundwater has required more attention. The aim of the present study is to establish a MODFLOW model in the groundwater modeling system software to simulate the movement of groundwater in the Turssaq alluvial fan which is located in the Qazaniyah city, east of Diyala Governorate. The solid model was used to define the aquifer in the study area. Using the GIS software, mapping and preparing the data needed to create a conceptual model were carried out. The data of the wells were used to create and define the aquifer, then a three-dimensional model was created. Measuring the water table for some wells were simultaneously monitored to determine the hydraulic conductivity values of the aquifer through the (PEST) package provided by the software. The hydraulic conductivity value of the main layer was 18 m/d. Then several readings of observation wells were recorded for the period extended from 1/Nov/2018 to 22/May/2019 for the calibration process in the unsteady situation and to determine the coefficient of storage. The value of the storage coefficient was defined as 0.001. Several scenarios were conducted for the study area to find the best distance between the wells. Three distances were tested, 500, 1000 and 1500 m. The operating periods were 6, 12 and 18 (hours/day). Results obtained from the model show that the best distance between the wells is 1000 meters with a maximum operating rate of 12 hours/day. The maximum discharge with the lowest distance and the lowest drawdown of the groundwater table are considered.
The deterioration of buried sewers during their lifetime can be affected by several factors leading to bad performance and can damage the infrastructure similar to other engineering structures. The Hydraulic deterioration of the buried sewers caused by sewer blockages while the structural deterioration caused by sewer collapses due to sewer specifications and the surrounding soil characteristics and the groundwater level. The main objective of this research is to develop deterioration models, which are used to predict changes in sewer condition that can provide assessment tools for determining the serviceability of sewer networks in Baghdad city. Two deterioration models were developed and tested using statistical software SPSS, the
... Show More
Objective:The current study aime to isolate Escherichia colifrom urinary tract infections(UTIs) in many Baghdad hospitals. The study concentrate on phylogenic groups and this was done based on triplex PCRmethod by primers besieged to three genetic markers, chuA, yjaA and TspE4.C2. Evaluate the relationship of phylogenic groups of E. coli isolates with the antibiotic-non sensitive patterns. Methodology:Four hundredof E.coli bacteria isolated from urine samples from five hospitals in Baghdad city include: Ghazi AL-Hariri, Ibin- Al-Beledi , AL-Iskan , AL-Nooman and AL-Yarmoke hospitals. Phylogenetic categorizatio
The objective of the research is to identify the efficiency of risk management in various names at Baghdad International Airport in the face of various risks (financial - technical - human - natural ..) facing the sample of the search of the General Establishment of Civil Aviation and the Iraqi Airways Company where the researcher identified the hypothesis that summarizes There is a significant significant correlation between risk management, risk management and risk review and assessment. The researcher used the means of research from observation and interviews with the relevant officials in this field, as well as used the questionnaire and distributed a sample of 170 employees in the field of risk management (SMS Department) in Iraqi A
... Show MoreThe parameter and system reliability in stress-strength model are estimated in this paper when the system contains several parallel components that have strengths subjects to common stress in case when the stress and strengths follow Generalized Inverse Rayleigh distribution by using different Bayesian estimation methods. Monte Carlo simulation introduced to compare among the proposal methods based on the Mean squared Error criteria.
The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis
... Show MoreMarkov chains are an application of stochastic models in operation research, helping the analysis and optimization of processes with random events and transitions. The method that will be deployed to obtain the transient solution to a Markov chain problem is an important part of this process. The present paper introduces a novel Ordinary Differential Equation (ODE) approach to solve the Markov chain problem. The probability distribution of a continuous-time Markov chain with an infinitesimal generator at a given time is considered, which is a resulting solution of the Chapman-Kolmogorov differential equation. This study presents a one-step second-derivative method with better accuracy in solving the first-order Initial Value Problem
... Show More