A square experimental arena with vegetation on one interior side was deployed in a Sharjah, United Arab Emirates desert. Individual darkling beetles (Coleoptera, Tenebrionidae) Akis subtricostata Redtenbacher, 1850 and Trachyderma philistina Reiche and Saulcy, 1857 were placed inside the arena at temperatures ranging between 27 - 49°C. Whether they chose the vegetated side of the arena or not was recorded, as well as how long it took for them to reach the vegetated side, if they chose it. Both species preferred the vegetated side at all temperatures, and the chance of them choosing the vegetated side increased significantly with increasing temperature (logistic regression, p = 0.0096 and p = 0.0003 for T. philistina and A. subtricostata, respectively). T.philistina and A. subtricostata always chose the vegetated side at temperatures above 31°and 44°C, respectively. Individual beetles that chose the vegetated side moved quickly and directly to it at temperatures above 30°C. Below 30°C, however, beetles tended to move slower and take more pauses within the arena. Time to reach the vegetated side declined significantly with increasing temperature (least-squares regression, p < 0.00005 for both species). A few individuals of both species died at the highest temperatures (48 - 49°C).
The reactions of ozone with 2,3-Dimethyl-2-Butene (CH3)2C=C(CH3)2 and 1,3-Butadiene CH2=CHCH=CH2 have been investigated under atmospheric conditions at 298±3K in air using both relative and absolute rate techniques, and the measured rate coefficients are found to be in good agreement in both techniques used. The obtained results show the addition of ozone to the double bond in these compounds and how it acts as function of the methyl group substituent situated on the double bond. The yields of all the main products have been determined using FTIR and GC-FID and the product studies of these reactions establish a very good idea for the decomposition pathways for the primary formed compounds (ozonides) and give a good information for the effe
... Show MoreThe effectiveness of upward training with weights to develop explosive power, characterized by speed and some functional variables for young volleyball players Many efforts of sports laboratories in various countries have been devoted to laying scientific foundations and rules in caring for the physical, skilled, planning, and psychological preparation of players and creating the conditions and requirements for reaching players to higher standards. The research aims to:1- Preparing an ascending training program with weights to develop explosive strength, which is characterized by speed and some functional variables for volleyball players.2- Identify the effect of the training program with upward training in weights to develop explosive stre
... Show MoreBACKGROUNDS Nasoalveolar molding (NAM) application is among presurgical management (PSM) techniques used for infants with cleft lip and palate (CLP). It helps to approximate the palatal cleft and to reshape the nasoalveolar complex prior to primary lip repair. This study aimed to explore types of PSM and the dental speciality provision for infants with CLP in Baghdad. The status of NAM usage and surgeons’ perceptions toward NAM usage were assessed. MATERIALS AND METHODS This is a cross-sectional paper-based questionnaire study that collected responses of surgeons perform primary lip and nose repair regarding PSM. The questionnaire was distributed amongst public and private hospitals in Baghdad. Twenty surgeons were enrolled (only those su
... Show MoreThe main objective of this study is to characterize the main factors which may affect the behavior of segmental prestressed concrete beams comprised of multi segments. The 3-D finite element program ABAQUS was utilized. The experimental work was conducted on twelve simply supported segmental prestressed concrete beams divided into three groups depending on the precast segments number. They all had an identical total length of 3150mm, but each had different segment numbers (9, 7, and 5 segments), in other words, different segment lengths. To simulate the genuine fire disasters, nine beams were exposed to high-temperature flame for one hour, the selected temperatures were 300°C (572°F), 500°C (932°F) and 700°C (1292°F) as recomm
... Show MoreAir pollution refers to the release of pollutants into the air that are detrimental to human health and the planet as a whole.In this research, the air pollutants concentration measurements such as Total Suspended Particles(TSP), Carbon Monoxides(CO),Carbon Dioxide (CO2) and meteorological parameters including temperature (T), relative humidity (RH) and wind speed & direction were conducted in Baghdad city by several stations measuring numbered (22) stations located in different regions, and were classified into (industrial, commercial and residential) stations. Using Arc-GIS program ( spatial Analyses), different maps have been prepared for the distribution of different pollutant
Using remote sensing technology and modeling methodologies to monitor changes in land surface temperature (LST) and urban heat islands (UHI) has become an essential reference for making decisions on sustainable land use. This study estimates LST and UHI in Salah al-din Province to contribute to land management, Urban planning, or climate resilience in the region; as a result of environmental changes in recent years, LANDSAT Satellite Imagery from 2014- 2024 was implemented to estimate the LST and UHI indexes in Salah al-din Province, ArcGIS 10.7 was use to calculate the indices, and The normalized mean vegetation index (NDVI) was calculated as it is closely related to extracting (LST
In this work we present a detailed study on anisotype nGe-pSi heterojunction (HJ) used as photodetector in the wavelength range (500-1100 nm). I-V characteristics in the dark and under illumination, C-V characteristics, minority carriers lifetime (MCLT), spectral responsivity, field of view, and linearity were investigated at 300K. The results showed that the detector has maximum spectral responsivity at λ=950 nm. The photo-induced open circuit voltage decay results revealed that the MCLT of HJ was around 14.4 μs
Exposure of reinforced concrete buildings to an accidental fire may result in cracking and loss in the bearing capacity of their major components, columns, beams, and slabs. It is a challenge for structural engineers to develop efficient retrofitting techniques that enable RC slabs to restore their structural integrity, after being exposed to intense fires for a long period of time. Experimental
investigation was carried out on twenty one slab specimens made of self compacting concrete, eighteen of them are retrofitted with CFRP sheets after burning and loading till failure while three of them (which represent control specimens) are retrofitted with CFRP sheet after loading till failure without burning. All slabs had been tested in a