Preferred Language
Articles
/
jmracpc-25
10.28936 STUDY OF THE KINETIC AND ADSORPTION ISOTHERM PARAMETERS FOR REMOVING COPPER AND IRON IONS FROM AQUEOUS SOLUTIONS BY USING AGRICALTURAL BY-PRODUCTS.: STUDY OF THE KINETIC AND ADSORPTION ISOTHERM PARAMETERS FOR REMOVING COPPER AND IRON IONS FROM AQUEOUS SOLUTIONS BY USING AGRICALTURAL BY-PRODUCTS.
...Show More Authors

Wheat straw was modified with malonic acid in order to get low cost adsorbent have a good ability to remove copper and ferric ions from aqueous solutions, chemical modification temperature was 120°C and the time was 12 h. Parameters that affect the adsorption experiments were studied and found the optimum pH were 6 and 5 for copper and iron respectively and the time interval was 120 min and the adsorbent mass was 0.1 g. The values for adsorption isotherms parameters were determined according to Langmuir [qmax were 54.64 and 61.7 mg/g while b values were 0.234 and 0.22 mg/l] , Freundlich [Kf were 16.07 and 18.89 mg/g and n were 2.77 and 3.16], Temkin [B were 0.063 and 0.074 j/mol and At were 0.143 and 1.658 l/g] and for Dubinin-Radushkevich [Kad were 3*106- and 9*107- , qs were 48.42 and 44.70 mg/g, E were 0.408 and 0.745 Kj/mol] for copper and iron ions respectively. The adsorption for both ions are physical since the n values in Freundlich were more than 1, the mean of free energy for Dubinin-Radushkevich were 0.408 and 0.745 Kj/mol and B values for Temkin equation B were 0.063 and 0.074 j/mol.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Construction Research Congress
Risk Perception of Construction Personnel: A Social Construct Outlook
...Show More Authors

Scopus (1)
Scopus
Publication Date
Thu Apr 20 2023
Journal Name
Maaen Journal For Medical Sciences
Evaluation of heated cure acrylic immersed in ozonated water
...Show More Authors

Background: Denture cleansing is an important step that can prevent the spread of infection and improve a patient's health, the durability of the dentures, and the overall quality of life; therefore, it is necessary to choose a suitable cleanser that, in addition to being effective, does not have an unfavorable effect on the qualities of the denture base resin itself when used for an extended period. Aim: This research aims to assess the effects of ozonated water on the surface roughness and hardness of heat-cured acrylic resin by immersion technique. Materials: Sixty bars shapemade of heat-cured acrylicweremanufactured.Thirty samples for every test, including: (surface hardness and surface roughness). Then, these samples were divided into

... Show More
View Publication
Crossref
Publication Date
Mon Sep 01 2008
Journal Name
Journal Of Engineering
MATHEMATICAL SIMULATION OF UNSTEADY FLOW THROUGH HOLLOW FIBER MEMBRANE
...Show More Authors

Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
ZnO Characterization of ZnO/GaAs heterojunction: ZnO thin films
...Show More Authors

ZnO thin films have been prepared by pulse laser deposition technique at room temperatures (RT). These films were deposited on GaAs substrate to form the ZnO/GaAs heterojunction solar cell. The effect of annealing temperatures at ( RT,100, 200)K on structural and optical properties of ZnO thin films has been investigated. The X-ray diffraction analysis indicated that all films have hexagonal polycrystalline structure. AFM shows that the grains uniformly distributed with homogeneous structure. The optical absorption spectra showed that all films have direct energy gap. The band gap energy of these films decreased with increasing annealing temperatures.  From the electrical properties, the carriers have n-type conductivity.  From

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
Computer-Aided-Design of low aberration electrostatic Immersion lens
...Show More Authors

A computerized investigation has been carried out to design an immersion lens
with low aberration operating under zero magnification condition using inverse problem.
The aberration is highly dependent on the shape of electrodes, for a preassigned electron
beam trajectory the paraxial-ray-equation is solved to determine the electrostatic potential
and field distribution.
From the knowledge of the potential and its first and second derivative the
electron optical properties were computed, the electrode geometry was determined from
the solution of Laplace equation.

View Publication Preview PDF
Publication Date
Fri Aug 02 2024
Journal Name
Journal Of Electrochemical Energy Conversion And Storage
Electrochemical Performance of Co1-xMnxFe2O4 Decorated Nanofiber Polyaniline Composites
...Show More Authors

The current work is concerned with preparing cobalt manganese ferrite (Co1-xMnxFe2O4) with different concentrations of cobalt and manganese (x=0.2, 0.4, and 0.6) and decorating it with polyaniline (PAni) for use in supercapacitive applications. The results of the X-ray diffraction (XRD) manifested a broad peak of PAni and a cubic structure of cobalt manganese ferrite having crystal size between 60 nm and 138 nm, which decreases with increasing concentration of Mn. The field emission scanning electron microscopy (FESEM) images evidenced that the PAni has nanofiber (NF) structures, according to the method of preparation, where the hydrothermal method was used. The magnetic properties of the prepared ferrite, as well as the prepared PAni/Co1-x

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Geotechnical Engineering And Sustainable Construction
Regulation of Supplier Standards in Iraq: Through Sustainability Standards
...Show More Authors

View Publication
Crossref
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
Investigation of Backfill Compaction Effect on Buried Concrete Pipes
...Show More Authors

The present study deals with the experimental investigation of buried concrete pipes. Concrete pipes are buried in loose and dense conditions of gravelly sand soil and subjected to different surface loadings to study the effects of the backfill compaction on the pipe. The experimental investigation was accomplished using full-scale precast unreinforced concrete pipes with 300 mm internal diameter tested in a laboratory soil box test facility set up for this study. Two loading platforms are used namely, uniform loading platform and patch loading platform. The wheel load was simulated through patch loading platform which have dimensions of 254 mm *508 mm, which is used by AASHTO to model the wheel load of a HS20 truck. The pipe-soil system

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Dec 31 2011
Journal Name
Al-khwarizmi Engineering Journal
Effect of Mixed Corrosion Inhibitors in Cooling Water System
...Show More Authors

The effect of mixed corrosion inhibitors in cooling system was evaluated by using carbon steel specimens and weight loss analysis. The carbon steel specimens immersed in mixture of sodium phosphate (Na2 HPO4) used as corrosion inhibitor and sodium glocunate (C6 H11 NaO7) as a scale dispersant at different concentrations (20,40, 60, 80 ppm) and at different temperature (25,50,75 and 100)ºC for (1-5) days. The corrosion inhibitors efficiency was calculated by using uninhibited and inhibited water to give 98.1%. The result of these investigations indicate that the corrosion rate decreases with the increase the corrosion inhibitors concentration at 80 ppm and at 100ºC for 5 days, (i.e,

... Show More
View Publication Preview PDF