Preferred Language
Articles
/
jmracpc-139
FLOW INJECTION ANALYSIS AND SPECTROPHOTOMETRIC DETERMINATION OF NIFEDIPINEIN PHARMACEUTICAL FORMULATION: FLOW INJECTION ANALYSIS AND SPECTROPHOTOMETRIC DETERMINATION OF NIFEDIPINEIN PHARMACEUTICAL FORMULATION
...Show More Authors

A new simple and sensitive spectrophotometric method is described for quantification of Nifedipine (NIF) and their pharmaceutical formulation. The selective method was performed by the reduction of NIF nitro group to yield primary amino group using zinc powder with hydrochloric acid. The produced aromatic amine was submitted to oxidative coupling reaction with pyrocatechol and ammonium ceric nitrate to form orange color product measured spectrophotometrically with maximum absorption at 467nm. The product was determined through flow injection analysis (FIA) system and all the chemical and physical parameters were optimized. The concentration range from 5.0 to 140.0 μg.mL-1 was obeyed Beer’s law with a limit of detection and quantitation 1.48 and 4.96 μg.mL-1 respectively. Agoodprecision,low scattering point of the calibration graph and good accuracyin addition, FIA introduced a good linear range with acceptable sensitivity. High correlation coefficient (0.9996) was found. The proposed method was successfully applied to assay NIF and its pharmaceutical dosage also could be utilized for pharmaceutical routine analysis of the drug.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Corrosion Parameters for a Cathodic Reaction Complicated by IR Drop Effect in a Flow System
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 12 2020
Journal Name
Baghdad Science Journal
Spectroscopy Characterization of Ethylene Vinyl Acetate Degradation by Different Kinds of Accelerated Aging
...Show More Authors

            This paper presents a sight about the chemical structure deformation of poly (ethylene-co-vinyl acetate) (EVA) samples according to the change ratio of rate constant values. Spectroscopy kinetics fluorescence curves are fitted for two characteristic wavelength domains of fluorescent intensities. The short wavelengths (320-400 nm) domain show spectra overlapping, while at long wavelengths (400-800 nm) domain spectra are arranged in regular for each specific accelerated aging time. The ratio of kinetics rate constant at long wavelengths to kinetics rate constant of short wavelengths is the criterion of the degree chemical structure deformation. Molar extrin

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Mon Nov 28 2022
Journal Name
F1000research
In vitro apical microleakage evaluation for different endodontic sealers by spectrophotometric analysis: an observational study
...Show More Authors

Background: It has been established that several filling techniques can affect apical leakage, which is responsible for 59% of endodontic failures. The primary goal of endodontic therapy is to create a tight seal that aids in repairing the periapical tissues, prevents apical periodontitis, and shields against root canal infection. The study aims to compare the apical sealing ability of epoxy resin based sealer  (AH plus), which is an epoxy-resin-based root canal sealer, GuttaFlow 2, which is a silicone-based root canal sealer, GuttaFlow bioseal is a bioactive glass-based root canal sealer, TotalFill HiFlow bioceramic (BC) sealer is a silicate-based root canal sealer (bioceramic sealer) using a single cone techn

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation of Rifampicin Suspension
...Show More Authors

     

Rifampicin is the drug of choice in treatment of tuberculosis. Also, it is effective in treatment of various bacterial infections.This study was carried out to prepare a stable suspension for rifampicin through preparation of different formulas of rifampicin aqueous suspension either as ready to use or as granular powder to be reconstituted.The selected formula (A) was evaluated and compared with commercial brand of rifampicin (Rifactine®) as a reference through measuring their dissolution rates and other physical properties.The results indicated that the selected formula had better dissolution rate compared with the reference suspension and the rheogram showed that the selected formula was less

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Aug 05 2024
Journal Name
Pharmacia
A validated spectrophotometric analysis for simultaneous estimation of vincristine sulfate and bovine serum albumin in pure preparations using Vierordt’s method
...Show More Authors

The novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LO

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Apr 04 2011
Journal Name
Ibn Al-haitham J.for Pure &appl.sci
Anew Spectrophotometric Method For The Determination of La (III) With 3-Hydroxy -4-(2-hydroxy –Phenyl azo)Naphthalene -1-Sulfonic Acid
...Show More Authors

A simple, rapid and sensitive spectrophotometric method has been proposed for the determination of La (III) using 3-hydroxy -4-(2-hydroxy-phenyl azo) naphthalene -1- sulfonic acid as a chromogenic reagent. This method is based on the formation of a red-pink colored complex, upon the reaction of La(III) with the reagent in an alkaline medium (pH= 9.50), having a maximum absorbance at 459 nm. Beer's law is valid in the concentration range 0.512 µg.ml-1 with a Sandell's sensitivity value of 0.0188 µg.cm-2 and molar absorptivity of 7376.12 L.mol-1.cm-1. The stoichiometric composition of the chelate is 1:3. The effect of the presence of different cations as interferants in the determination of La(III) under the given optimum conditions wer

... Show More
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hoisting System Performance
...Show More Authors

In this paper it is required to enhance the performance of a mechanical system (here: a Hoisting System) where it is preferred to lift a different payloads with approximately the same speed of lifting and keeping at the same time the good performance, and this of course needs some intelligence of the system which will be responsible on measuring the present load and taking into account the speed and performance desired in order to achieve the requirements or the criteria. The process therefore is a Mechatronics System design which includes a measuring system, a control or automation technique, and an actuating system. The criteria built here in this research using a given Hoist system's characteristics and parameters and changing one of

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 01 2014
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Debulking of Keloid Combined with Intralesional Injection of 5-Flurouracil and Triamcinolone versus Intralesional Injection of 5-Flurouracil and Triamcinolone
...Show More Authors

KE Sharquie, AA Noaimi, MR Al-Karhi, Journal of Cosmetics, Dermatological Sciences and Applications, 2014 - Cited by 2

View Publication
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
With Solvent Extraction Method, and via new Organic Reagent 2-(Benzo thiazolyl azo)-4,5- Diphenyl Imidazole for Spectrophotometric Determination of Copper (II) in different Samples
...Show More Authors

The new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and dis

... Show More
View Publication Preview PDF
Crossref