Preferred Language
Articles
/
jmracpc-112
DETERMINATION OF THE CHEMICAL COMPOSITION OF THE COWS, SHEEPS AND CHICKENS BONES AND THE POSSIBILITY OF USING THEIR FAT ECONOMICALLY.: DETERMINATION OF THE CHEMICAL COMPOSITION OF THE COWS, SHEEPS AND CHICKENS BONES AND THE POSSIBILITY OF USING THEIR FAT ECONOMICALLY.
...Show More Authors

This study includes applying chemical tests on cow, sheep and chicken bones including both hallow and flat. The results of chemical tests on bones mentioned the moisture percentage which was between 4.95-7.32 %, and it was noticed the difference in protein percentage among different kinds of bones, The highest protien percentage was 39.62 % in hallow chicken bones and the lowest was in hallow sheep bones 20.31%, at the same time, the highest Ash percentage was in hallow sheep bones48.11% , whereas the highest percentage of fat was in hallow cow bones 30%. The chemical and physical tests were conducted for extracted fat from hallow and flat bones for cows, sheeps and chicken. It was found that peroxide values (PV), and free fatty acids (FFA) tended to increase proportionally with extraction time at temperatures examined. The lowest values ware obtained after 3 hours as PVs were 0.93, 1.2, 1.0, 1.0, 1.33 and 1.46 meq/ kg oil respectively, FFA values were 0.15, 0.168, 0.187, 0.168, 0.206 and 0.225% respectively. The highest chemical indices for extracted fat from hallow and flat bones for cow and sheep was after 5 hours as PVs were 2.39, 1.8, 1.9, and 1.86 meq/ kg oil respectively, FFA values were 0.253, 0.300, 0.263 and 0.30% respectively. While, the highest chemical indices for extracted fat from hallow and flat chicken bones was after 4 hours, as PVs were 1.6 and 1.73 meq/ kg oil respectively, FFA values were 0.245 and 0.244% respectively. The obtained results showed values of smoking point tended to decrease proportionally as extraction time proceeding at different temperature used, highest values were recorded after extraction for 3 hours, smoking point values were 242.6, 231.33, 223.8, 217.66, 204.5and 204 °C respectively. The lowest physical values of fat extracted from hallow and flat bones of cow and sheep were obtained after 5 hours as the smoking point values were 230.33, 229.83, 203.4 and 204.83°C respectively. The lowest physical indices of fat extracted from hallow and flat chicken bones were obtained after 4 hours, as the smoking point values were 204 and 203.5 °C respectively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation of Alpha Tocopherol Acetate as a Powder Dosage Form by Adsorption
...Show More Authors

Alpha-tocopherol acetate is one of the most important vitamin E derivatives,that were used  as antioxidants. Adsorbents like kaolin, magnesium carbonate, and microcrystalline cellulose were used successfully to incorporate oily alpha-tocopherol acetate into an acceptable powder dosage form. The results revealed that microcrystalline cellulose as an adsorbents gave the best results with 50% loading capacity at time, 8 minutes before and after incubation period (3 months at 30C°), while kaolin and magnesium carbonate have been shown a significant difference before and after incubation. Addition of 1% w/w magnesium carbonate to the kaolin enhanced the loading capacity by decreasing the time of adsorption from 20 to 6 minutes and 47

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Indian Journal Of Forensic Medicine And Toxicology
Color stability of different aesthetic resin composite materials: A digital image analysis
...Show More Authors

Scopus (3)
Scopus
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Band Gap Characterization of Thermally Treated Hybrid Blend ZnPc/CdS Thin Films
...Show More Authors

Spin coating technique used to prepare ZnPc, CdS and ZnPc/CdS blend thin films, these films annealed at 423K for 1h, 2h and 3h. Optical behavior of these films were examined using UV-Vis. and PL. The absorption spectrum of ZnPc shows a decreasing in absorption with the increase of annealing time while CdS spectrum give a clearly absorption peak at~510 nm. Energy gap of ZnPc increases from 1.41 to 1.52 eV by increasing the annealing time. Eg of CdS decrease by increasing annealing time, from 2.3 eV to 2.2 eV. The intensities of the peaks obtained from PL spectra were strongly dependent on annealing time and confirmed the results obtained from UV-Vis. D.C. conductivity measurement showed that all the thin films have two differen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Journal Of Systems And Software
Development of Java based RFID application programmable interface for heterogeneous RFID system
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering
Nonlinear Finite Element Analysis of Fiber Reinforced Concrete Pavement under Dynamic Loading
...Show More Authors

The analysis of rigid pavements is a complex mission for many reasons. First, the loading conditions include the repetition of parts of the applied loads (cyclic loads), which produce fatigue in the pavement materials. Additionally, the climatic conditions reveal an important role in the performance of the pavement since the expansion or contraction induced by temperature differences may significantly change the supporting conditions of the pavement. There is an extra difficulty because the pavement structure is made of completely different materials, such as concrete, steel, and soil, with problems related to their interfaces like contact or friction. Because of the problem's difficulty, the finite element simulation is

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Optical properties of TiO2 thin films prepared by reactive d.c. magnetron sputtering
...Show More Authors

TiO2 thin films were deposited by reactive d.c magnetron sputtering method on a glass substrate with various ratio of gas flow (Oxygen /Argon) (50/50, 100/50 and 150/50) at substrate temperature 573K. It can be observe that the optical energy gap of TiO2 thin films dependent on the ratio of gas flow (oxygen/argon), it varies between (3.45eV-3.57eV) also it is seen that the optical constants (α, n, K, εr and εi ) has been varied with the change of the ratio of gas flow (Oxygen /Argon).

View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Correlating CT findings of stroke with hyperglycemia in acute ischemic stroke patients
...Show More Authors

Background: Studies show that diabetic patients have a higher incidence of ischemic stroke than non-diabetic patients. In the Framingham study the incidence of thrombotic stroke was 25 times higher in diabetic men and 36 times higher in diabetic women than in those without diabetes

Objectives: aim of this study to analyze topography in diabetic patients.

Type of study:  Cross sectional study.

Methods: 48 patients with acute stroke were classified into 4 groups: euglycemic, stress hyperglycemia, newly diagnosed diabetics, and known diabetics.

Results:no significant differences were found in the type, site or size of st

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Aug 01 2013
Journal Name
Micron
Computational investigation of electron path inside SEM chamber in mirror effect phenomenon
...Show More Authors

View Publication
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sat Apr 29 2023
Journal Name
Research Journal Of Pharmacy And Technology
Assessment of Serum Neopterin Levels in patients hospitalized with severe COVID-19
...Show More Authors

Background: COVID-19 has caused a considerable number of hospital admissions in China since December 2019. Many COVID-19 patients experience signs of acute respiratory distress syndrome, and some are even in danger of dying. Objective: to measure the serum levels of D-dimer, Neutrophil-Lymphocyte count ratio (NLR), and neopterin in patients hospitalized with severe COVID-19 in Baghdad, Iraq. And to determine the cut-off values (critical values) of these markers for the distinction between the severe patients diagnosed with COVID‐19 and the controls. Materials and methods: In this case-control study, we collect blood from 89 subjects, 45 were severe patients hospitalized in many Baghdad medical centers who were diagnosed with COVID

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF