Preferred Language
Articles
/
jkmc-9
Role of Diffusion-Weighted MR Imaging in Characterization of Posterior Fossa Tumors
...Show More Authors

Background: Conventional  MR imaging is essential for diagnosis and evaluation of the posterior fossa tumors  Objectives: To assess the value of diffusion weighted imaging and apparent diffusion coefficient in making distinction between different histological types of posterior fossa tumors.

Type of the study: Cross-sectional study.

Methods: Brain MRI and DWI assessed 19 patients (12 female and 7 male) with MRI diagnosis of posterior fossa tumors. absolute ADC values of contrast -enhancing solid tumor region and ADC ratio of solid tumor to ADC of normal -appearing deep White matter were compared with histological diagnosis postoperatively .The mean ADC value and ratio were determined by using a 2-tailed T test. Results: In eight of  medulloblastoma ,The mean  ADC value was 0.67±0.14x 10-3 mm 2/s  and  ratio 0.86±0.19  ,   ependymoma (n=3), ADC value 1.09 ±0.14 x10 -3 mm 2 /s and ratio 1,43±0.13   ,  pilocytic astrocytoma (n=4) ADC value 1,72 ±0.27x10 -3 mm2/s and ratio 2.19±0.4, brainstem glioma (n=2) with ADC value1.18±0.06 x10-3mm2/s and ratio 1.64±0.08 , haemangioblastoma  (n=1) with ADC value1.46x10-1mm2/s and ratio 1.87 , and meningioma with ADC value 0.72x10-3mm2/s and ratio 0.85. ADC values were higher in JPA than in ependymomas and medulloblastoma (P value <o,o5).ADC ratio were also  statistically significant difference among these three tumors type .

Conclusion: calculation of apparent diffusion coefficient value in the solid enhancing portion of tumor   seems to be reliable for  differentiate between  medulloblastoma at one end and , juvenile pilocytic astrocytoma (JPA) and ependymoma at other end as the former has ADC of < 1 while other tumors have ADC value of >1.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 30 2021
Journal Name
Al-kindy College Medical Journal
Diagnostic Evaluation of Uterine Artery Doppler Imaging for the Prediction of Early Abnormal Pregnancy
...Show More Authors

Objective: to assess the predictive value of Doppler imaging of the uterine artery in the identification of early intrauterine abnormal pregnancy as compared to a normal intrauterine pregnancy.

Subjects and methods: one hundred and twenty pregnant ladies, at their 6-12 weeks of gestation, with a singleton pregnancy were included in this population-based case-control study. Thirty women with a missed miscarriage, 30 with hydatidiform mole, 30 with a blighted ovum, and 30 as a control group, without risk factors, underwent Doppler interrogation of the uterine arteries. Resistive index (RI), pulsatility index (PI), and the systolic/diastolic ratio (S/D) were measured for both sides. The t-test, or ANOVA test when a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 15 2026
Journal Name
Journal Of Research In Pharmacy
In-vivo examination of nasal-to-brain administration for delivering rhodamine B nanospanlastic for fluorescent vesicle imaging
...Show More Authors

This study investigated the efficacy of nasal injection of rhodamine B nanospanlastic (RBN) for magnetic vesicle imaging of specific brain locations. Effective delivery of RBN, which functions as fluorescence agents, to specific brain regions is necessary to achieve fluorescence particle imaging (FPI). There has been interest in nasal administration as a means of administering drugs directly to the brain, thereby circumventing the blood-brain barrier. We offered experimental nasal fluorescence agent administration by in vivo research. Fluorescent tests confirmed that, upon nasal delivery, the intended nanospanlastic migrated into the brain. Furthermore, using fluorescent microscopy, we demonstrated how these nanospanla

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Mar 29 2024
Journal Name
Iraqi Journal Of Science
Determination of Timewise-Source Coefficient in Time-Fractional Reaction-Diffusion Equation from First Order Heat Moment
...Show More Authors

     This article aims to determine the time-dependent heat coefficient together with the temperature solution for a type of semi-linear time-fractional inverse source problem by applying a method based on the finite difference scheme and Tikhonov regularization. An unconditionally stable implicit finite difference scheme is used as a direct (forward) solver. While by the MATLAB routine lsqnonlin from the optimization toolbox, the inverse problem is reformulated as nonlinear least square minimization and solved efficiently. Since the problem is generally incorrect or ill-posed that means any error inclusion in the input data will produce a large error in the output data. Therefore, the Tikhonov regularization technique is applie

... Show More
Preview PDF
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Thu Jan 30 2014
Journal Name
Al-kindy College Medical Journal
Discrimination of Malignant from Acute Benign Compression Spinal Fractures with Magnetic Resonance imaging
...Show More Authors

Background: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A PARTICULAR SOLUTION OF THE TWO AND THREE DIMENSIONAL TRANSIENT DIFFUSION EQUATIONS
...Show More Authors

A particular solution of the two and three dimensional unsteady state thermal or mass diffusion equation is obtained by introducing a combination of variables of the form,
η = (x+y) / √ct , and η = (x+y+z) / √ct, for two and three dimensional equations
respectively. And the corresponding solutions are,
θ (t,x,y) = θ0 erfc (x+y)/√8ct and θ( t,x,y,z) =θ0 erfc (x+y+z/√12ct)

View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Jordan Journal Of Biological Sciences
The Variations in Saliva and Serum Total Peroxidases System's Activity in Patients with Different Oral Tumors
...Show More Authors

Salivary peroxidases have biological functions of particular importance to oral health. The aim of this paper is to shed the light on saliva and serum total peroxidases activity as well as the activity of each of salivary peroxidase (SPO) and myeloperoxidase (MPO) in patients with oral tumors. The studied participants were divided into two groups: the first group included 18 oral squamous cell carcinoma patients and 20 age and gender-matched healthy controls while the second group consisted of 20 oral ossifying fibroma patients and 23 age and gender-matched healthy controls. Total peroxidases activity was determined, and its specific activity was calculated in serum and whole mixed saliva as well as in the supernatant and pellet fractions

... Show More
Scopus (2)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Finding timewise diffusion coefficient from nonlocal integral condition in one-dimensional heat equation
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
The Product of Automorphic Weighted Composition Operators on Hardy Space H <sup>2</sup>
...Show More Authors
Abstract<p>Let <inline-formula> <tex-math><?CDATA $n\in {\mathbb{N}},{p}_{i}\in {\rm{U}},{\alpha }_{{P}_{i}}(z)=\frac{{p}_{i}-z}{1-{\bar{p}}_{i}z}(z\in {\rm{U}})$?></tex-math> <math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mrow> <mi>n</mi> <mo>∈</mo> <mi>ℕ</mi> <mo>,</mo> <msub> <mi>p</mi> <mi>i</mi> </msub></mrow></math></inline-formula></p> ... Show More
View Publication
Scopus Crossref
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm

... Show More
Publication Date
Thu Jul 21 2022
Journal Name
Neuro Quantology
Astronomical Observation between Diffraction Limited Coherent and Incoherent Imaging Systems
...Show More Authors

Numerical simulations are carried out to evaluate the coherence concept’s effect on the performance regarding the optical system, when observing and imaging the planet’s surface. In numerous optical approaches, the coherence qualities of light sources play an important role. This paper provides an overview about the mathematical formulation of temporal and spatial coherence and incoherence properties of light sources. The circular aperture was used to describe the optical system like a telescope. The simulation results show that diffraction-limited for incoherent imaging system certainly improves the image. Yet, the quality of the image is degraded by the light source's highly spatial and temporal coherence properties, resulting in a

... Show More