Preferred Language
Articles
/
jkmc-959
Serum Pseudocholinesterase as a Biomarker in the Differentiation between Gastric Cancer and Benign Gastric Diseases
...Show More Authors

Background: Worldwide gastric cancer is the fifth most common cancer with poor prognosis. In early stages, it is hard to distinguish gastric cancer from benign gastric diseases, resulting in delayed diagnosis. There is a need to develop a biomarker for differentiating between gastric cancer and benign gastric diseases. Serum cholinesterase is synthesized in liver and released into plasma, and it has an important role in oncogenesis.

Objectives: To determine the correlation between serum cholinesterase activity and gastric cancer, in comparison to benign gastric diseases.

Subjects and Methods: A case control study carried out at Medical City Directorate\ Gastroenterology, Hepatology Hospital, and at Oncology Teaching Hospital from April 2022 to September 2022. It involved 25 patients with gastric cancer and age matched 25 patients with benign gastric diseases. Serum cholinesterase activity was determined by a colorimetric method..

Results: There was a significant difference in the mean level of serum cholinesterase between gastric cancer group (5339.28 U/L±1816) and benign gastric diseases group (7516.92 U/L±2351) with (P value<0.001). Significant association between low levels of serum cholinesterase and early cancer stages and grades (P value<0.001). Serum cholinesterase showed 60% sensitivity and 80% specificity in differentiating between gastric cancer and benign gastric diseases with optimal cutoff value of 5568U\L.

Conclusions: Serum cholinesterase can be considered as a potential rapid and non-invasive biomarker for differentiating between gastric cancer and benign gastric diseases.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Science Of The Total Environment
Sustainable application of tubular photosynthesis microbial desalination cell for simultaneous desalination of seawater for potable water supply associated with sewage treatment and energy recovery
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Mon Oct 11 2021
Journal Name
Nano Hybrids And Composites
Far Infrared Laser Detector Based on Multi-Walled Carbon Nanotubes and Blend of (Polyaniline - Polymethyl Methacrylate) Polymers with Methyl Blue Dye for Photoconductive Applications
...Show More Authors

Infrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector

... Show More
View Publication
Crossref (1)
Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Environmental Nanotechnology, Monitoring &amp; Management
Photodegradation of tetracycline antibiotic by ternary recyclable Z-scheme g-C3N4/Fe3O4/Bi2WO6/Bi2S3 photocatalyst with improved charge separation efficiency: Characterization and mechanism studies
...Show More Authors

View Publication
Scopus (32)
Crossref (9)
Scopus Crossref
Publication Date
Tue Oct 01 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparison of ََQuality of Life and Treatment Satisfaction among Sample of Iraqi Patients Using Anticoagulant Therapy (Warfarin or Non-Vitamin K Antagonist Oral Anticoagulants)
...Show More Authors

Background: Oral anticoagulation medication, warfarin and non-vitamin k antagonist oral anticoagulants  (NOAC) may require long term use which may affect patients’ satisfaction with their treatment and their quality of life (QOL). Objective: To compare the quality of life and treatment satisfaction among groups of patients using different anticoagulant therapies (warfarin and NOAC). Patients and methods: A cross-sectional study was performed at Ibn Al-Bitar Hospital for cardiac surgery in Baghdad in the period between December 2022 to May 2023. The study population included a convenient sample of patients receiving either warfarin or non-vitamin k antagonist oral anticoagulants treatment. The Arabic version of the short form 12

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jan 16 2025
Journal Name
Journal Of Biological Control
Toxicity of polymeric nanocapsules prepared from &lt;i&gt;Moringa oleifera&lt;/i&gt; leaf extract against the larvae of &lt;i&gt;Culex pipiens&lt;/i&gt; (Diptera: Culicidae)
...Show More Authors

The study aimed to prepare a nanocapsules formulation from the acetonic extract of Moringa oleifera leaves, using polymeric capsules, and test its toxicity against the third instar larvae of Culex pipiens mosquitoes. The leaf extract was prepared using acetone as a solvent, and the nano polymeric capsules were prepared using the synthetic polymer polyethylene glycol 4000. The results showed the successful preparation of nano polymeric capsules from the leaf extract, with an average particle size of 259.2 nm, and a nanocapsule diameter of 263.83 nm, as determined by DLS and SEM analysis, respectively. The toxicity results indicated that the nano polymeric capsules of the leaf extract exhibited higher mortality rates, reaching 97.6% a

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of The College Of Languages (jcl)
Hidden messages in (Pour un oui ou pour un non) of Nathalie Sarraute: Les messages cachés dans "Pour un oui ou pour un non" de Nathalie Sarraute
...Show More Authors

       The implicit is the narrative technique used to give indirect hidden messages. To read between the lines means to understand the implicit meaning that is not directly indicated. This technique is expressed in two forms: the hypothesis and the implications of linguistic and non-linguistic rules. Nathalie Sarraute’s "Pour un oui ou pour un non" states this narrative method through her character’s verbal and non-verbal dialogue. The present paper discusses the implicit method and shows the reason behind which  the author uses it in her play "Pour un oui ou pour un non".

Résumé

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 01 2012
Journal Name
Australian Journal Of Basic And Applied Sciences
Electrochemical interferences of Mn<sup>2+</sup> with Hg<sup>2+</sup>, Cd<sup>2+</sup> and Cu<sup>2+</sup> at different modified GCE
...Show More Authors

Glassy carbon electrode (GCE) was modified with carbon nanotubes CNT and C60 by attachment and solution evaporation techniques, respectively. CNT/Li+/GCE and C60/Li+/GCE were prepared by modifying CNT/GCE and C60/GCE in Li+ solution via cyclic voltammetry (CV) potential cycling. The sensing characteristics of the modified film electrodes, demonstrated in this study for interference of Mn2+ in different heavy metals ion esp. Hg2+, Cd2+ and Cu2+. The interfering effect was investigated that exert positive interference on the redox peaks of Mn2+. The modification of GCE with nano materials and Li+ act an enhancement for the redox current peaks to observe the effect of interference for Mn2+ in 1:1 ratio with different heavy metals ion.

Scopus (3)
Scopus
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Experimental Study of Spatial Self-Phase Modulation (SSPM) Based on Laser Beam and Hybrid Functionalized Carbon Nanotubes/Silver Nanoparticles (F-Mwcnts/Ag-Nps) Acetone Suspensions
...Show More Authors

Focusing of Gaussian laser beam through nonlinear media can induce spatial self- phase modulation which forms a far field intensity pattern of concentric rings. The nonlinear refractive index change of material depends on the number of pattern rings. In this paper, a formation of tunable nonlinear refractive index change of hybrid functionalized carbon nanotubes/silver nanoparticles acetone suspensions (F-MWCNTs/Ag-NPs) at weight mixing ratio of 1:3 and volume fraction of 6x10-6 , 9x10-6 , and 18x10-6 using laser beam at wavelength of 473nm was investigated experimentally. The results showed that tunable nonlinear refractive indices were obtained and increasing of incident laser power density led to increase the nonlinear refractive inde

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 01 2024
Journal Name
Indonesian Journal Of Chemistry
Synthesis, Structure and Biological Activity Studies of New Metal Ion Complexes Based on 3-[(3-Hydroxynaphthalene-2-yl-ethylidene)-hydrazono]-1,3-dihydro-indol-2-one
...Show More Authors

In the present study, a novel ligand (L) made of 2-hydroxynaphthaldehyde and 3-hydrazone-1,3-dihydro-indole-2-one(3-[(3-hydroxynaphthalen-2-yl-ethylidene)-hydrazono]-1,3-dihydro-indol-2-one). The ligand was characterized by FTIR, UV-vis, mass, 1H-NMR, 13C-NMR, and CHN elemental analysis. New complexes of this ligand were created by treating methanol and a drop of DMF solution of the produced ligand with the hydrated metal salts of Mn(II), Co(II), Ni(II), Cu(II), and Zn(II) in a molar ratio of 2:1 (L:M). As a result, complexes have been emerged and identified FTIR, UV-vis, C.H.N., chloride-containing, molar conductance, magnetic susceptibility, and atomic absorption. The characterization result for each complex indicated complexes wi

... Show More
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More