Preferred Language
Articles
/
jkmc-94
The Immediate And Intermediate Results Of Percutaneous Balloon Aortic Valvuloplasty In Patients With Congenital Valvular Aortic Stenosis
...Show More Authors

Background: Aortic valve stenosis results from minor to severe degrees of aortic valve maldevelopment. This stenosis causes mild to severe obstruction of the left ventricular outflow .

Objectives : to study the immediate and intermediate results of percutaneous balloon aortic valvuloplasty in patients with congenital valvular aortic stenosis .

Type of the study: A prospective study.

Methods: The study was done on thirty five patients with congenital valvular aortic stenosis who had percutaneous balloon aortic valvuloplasty  in Ibn Al- Bitar Center for Cardiac Surgery from May 2009 to February 2011.

Results: Twenty seven patients were male (77.2%) and 8 patients were female (22.8%), male to female ratio 3.5/ 1, . The aortic valve was bicuspid in 18 patients (51.4%) while 17 patients ( 48.6%) had tricuspid aortic valve. Balloon aortic valvuloplasty was successful in 30 patients (85.7%),. Maximum peak instantaneous Doppler pressure gradient across the aortic valve 24 hours postprocedural echocardiography showed reduction which is statistically significant. New aortic regurgitation had occurred in 15 patients ( 42.8%), it was mild in 9 patients ( 25.6%), moderate in 5 patients ( 14.3%) and severe in 1 patient( 2.9%) which is statistically significant. The follow up of 12.57 ± 3.88 ( 3- 22) months after intervention was done for all patients using echocardiography Doppler study, reveal the maximum peak instantaneous Doppler pressure gradient  across the aortic valve was raised  which is statistically significant. The aortic regurgitation was present in 18 patients (51.4%) , it was mild in 9 patients (25.7%) , moderate in 6 patients (17.1%) and severe in 3 patients  ( 8.6%). No mortality had been reported during the procedure or on follow up.

                                                                                 Conclusion: Aortic balloon valvuloplasty is safe and effective procedure in the treatment of congenital valvular aortic stenosis but mild aortic regurgitation is the most common immediate complication of aortic balloon dilatation and progressive aortic regurgitation is a major problem during the intermediate follow up.

                                                                                                                                              

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Reduction of Noise and Vibration of Spur Gear by Using Asymmetric Teeth Profiles with Tip Relief
...Show More Authors

Reduction of noise and vibration in spur gear experimentally by using asymmetric teeth profiles with tip relief was presented. Both of classical (symmetric) and asymmetric (with and without tip relief) spur gears are used in this work. Gear test rig was constructed to achieve torsional vibration measuring, and two modified cutters are designed and manufactured to achieve tooth profile modifications. First to cut asymmetric gear tooth with pressure angles (14.5o/25 o) without tip relief for loaded and unloaded tooth sides respectively, and second to cut asymmetric gear tooth with pressure angles (14.5o/25 o) for loaded and unloaded tooth sides respectively with tip relief to ach

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2022
Journal Name
International Information And Engineering Technology Association
Countermeasure of Riverbanks Local Scour and Deposition Using Different Shapes of Multiple Groynes with Different Spacing
...Show More Authors

In current study a computation fluid dynamic (CFD) technique was used to investigate the effect of groynes shape and spacing on the scour pattern and the maximum scour depth in open channel flow. CFD model have been validated throughout comparing the numerical results with three previous experimental studies for a single groyne located in open channel with three different shapes (L, quadrant, and parabola shapes). The comparison revealed very good agreement between numerical results of the maximum scour depth with the results of all experimental models. Moreover, investigations of the effect of multi-groynes (three groynes and four groynes) arranged in parallel with constant spacing and also with variable spacing have been done, the

... Show More
Crossref (2)
Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
Measurement Integration of business model disclosure with qualitative characteristics of accounting information (Relevant and Raithful Representation)
...Show More Authors

The research aims at integrating the disclosure of the business models with the qualitative characteristics of accounting information. To achieve this, the elements of the business model should be identified and disclosed, and then study the possibility of integrating the disclosure of the business model with the qualitative characteristics of accounting information.

To achieve this objective, the research was based on the indicators of disclosure of the business model of the International Accounting Standards Board to measure the disclosure of the business model.

The research reached a number of conclusions, the most important of which were as follows:

Fi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Chemical Methodologies
Study of Optical and Structural Properties of CdTe Quantum Dots Capped with 3MPA Using Hydrothermal Method
...Show More Authors

Quantum dots (QDs) can be defined as nanoparticles (NPs) in which the movement of charge carriers is restricted in all directions. CdTe QDs are one of the most important semiconducting crystals among other various types where it has a direct energy gap of about 1.53 eV. The aim of this study is to exaine the optical and structural properties of the 3MPA capped CdTe QDs. The preparation method was based on the work of Ncapayi et al. for preparing 3MPA CdTe QDs, and hen, the same way was treated as by Ahmed et al. via hydrothermal method by using an autoclave at the same temperature but at a different reaction time. The direct optical energy gap of CdTe QDs is between 2.29 eV and 2.50 eV. The FTIR results confirmed the covalent bonding betwee

... Show More
View Publication Preview PDF
Scopus (7)
Scopus
Publication Date
Tue Oct 22 2024
Journal Name
Reports Of Biochemistry And Molecular Biology
Association of Serum Anti-Mullerian Hormone and Free Testosterone with Different Phenotypes of Polycystic Ovary Syndrome
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Stomatology
Association of self-reported symptoms of xerostomia with vaping and cigarette smoking: a cross-sectional study
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Aip Conference Proceedings
Study of some physical and mechanical properties of paper sheets treated with different polymeric adhesive solution
...Show More Authors

The present researchers are trying to enhance the properties of paper sheet that used widely in many fields such as printing and packaging. The enhancement of paper quality is also possible to preserve paper documents of all kinds, as they are the true record, full of the history, achievements of the human being and the intellectual and cultural of the country. It is possible to improve its physical and mechanical properties and preserve them from damage through the use of some solutions of polymeric adhesives, which act as protective barriers against water and moisture penetration. The paper also has the advantage of porosity, which has been overcome by using three types of polymeric adhesives (Nitro Cellulose, Polyvinyl alcohol acetate, a

... Show More
Scopus (1)
Scopus
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Photochemistry And Photobiology A: Chemistry
Construction of co-zeolitic imidazolate framework/Bi2WO6 heterojunction photocatalyst with improved adsorption and photodegradation of ciprofloxacin
...Show More Authors

View Publication
Scopus (47)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of surface microhardness of enamel surface treated with Nano- HAP serum before and after bleaching
...Show More Authors

Background: Although bleaching is typically considered a safe procedure, various investigations have found minor negative effects and changes in mineral composition. The aim was to Evaluate and compare the efficacy of using Nanohydroxyapatite serum on surface microhardness of enamel surface before and after bleaching with chemically cured Boost bleaching. Material and methods: ten sound human permanent upper and lower premolar teeth were used and their roots were removed 2 mm apically to the cementoenamel junction, the crowns were sectioned mesiodistally into two halves buccal and lingual/palatal, the buccal surface was further subdivided into two halves. The samples were embeded in an acrylic resin, resulting in 30 specimens divide

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Inorganic Chemistry Communications
Investigation of optical, mechanical, thermal, wettability, and antibacterial activity of polyvinyl alcohol mixed with clay nanoparticles
...Show More Authors

View Publication
Scopus (15)
Crossref (16)
Scopus Clarivate Crossref