Preferred Language
Articles
/
jkmc-898
Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy: IOP Level After SO Removal
...Show More Authors

Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.

Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)

Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO removal. Follow-up was performed at 1, 4, and 8 weeks after SO removal. IOP was measured by Goldman applanation tonometer. Patients with IOP > 21 mm Hg at 8 weeks post-operatively with or without anti-glaucoma mediations were considered as persistent IOP elevation after SO removal.

Result: Sixty eyes of 60 patients were included. Twenty eyes had persistent IOP elevation after SO removal on first week postoperative. It decreased to 14 eyes on 4th week after SO removal and further decreased to 12 eyes on 8th week af-ter SO removal. The percentage of persistent IOP elevation following SO remov-al was about 20%  on 8th week of SO removal. 

Conclusion: Persistent IOP elevation sometimes happens after SO removal. Therefore, removing SO does not simply treat the elevated IOP happened during SO injection. Patients after SO removal should be followed up for IOP for several weeks and should be treated medically or surgically as required.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Autogenous Onlay Graft with Compression Plate for Treatment of Persistent Humeral Shaft Aseptic Non-union with Failed Previous Surgery
...Show More Authors

BACKGROUND: The humeral shaft fractures have a good rate of union, despite this fact, still there is a significant rate of nonunion after nonoperative treatment and more often after operative treatment. AIM: The aim of the study is to evaluate the autogenous onlay graft with compression plate for treatment of persistent humeral shaft non-union with failed previous surgery both radiological and functional outcome. MATERIALS AND METHODS: A prospective study on twenty patients having persistent aseptic non-union age between 20 and 60 years old, after failed surgical treatment of fractures humeral shaft in Al-Zahra teaching and Al-Kindy teaching hospitals, while infected nonunion, diabetes mellitus, secondary metastasis, smoking, a

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
Salivary Interleukin-6 Level in Iraqi Patients with Oral Lichen Planus receiving Platelet-Rich Plasma Injections
...Show More Authors

Background: Interleukin-6 (IL-6) is a cytokine that has several functions, including stimulating growth and inhibiting cell death. It has the potential to operate as a biomarker for the accurate prediction of disease severity and activity, platelets-rich plasma was used in the treatment of oral lichen planus and can change the salivary IL-6 level.

Objectives: To study the clinical outcome of intralesional platelets-rich plasma in patients with oral lichen planus and to measure salivary IL-6 levels before and after the treatment with platelets-rich plasma were the aims of this study.

Subjects and Methods: In this clinical trial, for each patient a standardi

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EFFECT OF ADDING QUERCETIN TO TRIS EXTENDER IN SOME SEMEN CHARACTERISTICS OF AWASSI RAMS AFTER DIFFERENT PERIODS OF CRYOPRESERVATION: EFFECT OF ADDING QUERCETIN TO TRIS EXTENDER IN SOME SEMEN CHARACTERISTICS OF AWASSI RAMS AFTER DIFFERENT PERIODS OF CRYOPRESERVATION
...Show More Authors

ABSTRACT

The study evaluated the effect of adding quercetin to some characteristics of the sperm of the ram. This study was conducted in the animal field, Department of Animal Production, College of Agricultural Engineering Science, University of Baghdad for the period 5/12/2021 to 20/2/2022. In this experiment, 3 rams were used at the age of 2-2.5 years and weighed 50-55 kg. The semen was collected early in the morning and once a week and the semen was pooled to remove the individual differences. The treatments were divided: quercetin-free control group, treatment T1 (3 µL/mL quercetin), T2 treatment (6 µL/mL quercetin), T3 treatment (9 µL/mL quercetin). The result of the study showed

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 28 2020
Journal Name
The Iraqi Journal Of Science
Removal of Aniline Blue from Textile Wastewater using Electrocoagulation with the Application of the Response Surface Approach
...Show More Authors

This paper investigated the treatment of textile wastewater polluted with aniline blue (AB) by electrocoagulation process using stainless steel mesh electrodes with a horizontal arrangement. The experimental design involved the application of the response surface methodology (RSM) to find the mathematical model, by adjusting the current density (4-20 mA/cm2), distance between electrodes (0.5-3 cm), salt concentration (50-600 mg/l), initial dye concentration (50-250 mg/l), pH value (2-12 ) and experimental time (5-20 min). The results showed that time is the most important parameter affecting the performance of the electrocoagulation system. Maximum removal efficiency (96 %) was obtained at a current density of 20 mA/cm2, distance be

... Show More
Crossref (8)
Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Journal Of Engineering Science And Technology
Applying box-behnken design with statistical optimization for removal vat orange dye from aqueous solution using kaolin
...Show More Authors

Scopus (5)
Scopus
Publication Date
Sun Sep 01 2024
Journal Name
Baghdad Science Journal
Removal of Some Heavy Metals from Polluted Water Using New Schiff Base for Polyacrylamide with Zeolite Nanocomposites
...Show More Authors

تضمن هذا العمل تحضير ليكند قاعدة شيف جديدة مشتقة من مادة البولي أكريلاميد والكلوترالديهايد [(2S, 2'S) – N, N' - (pentane-1, 5-diylidene) bis (2- methylbutan amide)]  مع بعض المعادن الثقيلة (Cr + 3 Mn + 3 , Fe + 3 , ,Co + 2,  Ni + 2 ,Cu + 2  Zn + 2 , Cd + 2,) لتنتج المعقدات المقابلة. تم تشخيص قواعد شيف ومعقداتها المعدنية بأستخدام طيف الأشعة تحت الحمراء والأشعة المرئية وفوق البنفسجية، والتوصيلية ,وقيم المغناطيسية والتحليل الحراري الوزني وحيود الأشعة السينية ومجه

... Show More
View Publication
Scopus (5)
Scopus Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Chemical Engineering Research And Design
Nickel removal from simulated wastewater using a novel bio-electrochemical cell with packed bed rotating cylinder cathode
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Mar 25 2018
Journal Name
Biomedical And Pharmacology Journal
Apical Extrusion of Debris and Irrigants After using Different Irrigation Needles and Systems With Different Depth of Penetration (A Comparative Study)
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Fri Oct 07 2022
Journal Name
Texas Journal Of Engineering And Technology
Estimation of Pore Pressure and In-Situ Stresses for Halfaya Oil Field: A Case Study
...Show More Authors

Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Color Stability of Different Aesthetic Archwires after Immersion into Different Types of Mouthwashes(An In Vitro Study)
...Show More Authors

Background: Because of the demands for aesthetic orthodontic appliances have increased, aesthetic archwires have been widely used to meet patient's aesthetic needs. The color stability of aesthetic archwires is clinically important, any staining or discoloration will affect patient’s acceptance and satisfaction. This study was designed to evaluate the color stability of different types of aesthetic archwires after immersion into different types of mouth washes. Materials and methods: Four brands of nickel titanium coated aesthetic arch wires: Epoxy coated (Orthotechnology and G&H) and Teflon coated (Dany and Hubit) were evaluated after 1 week, 3 weeks and 6 weeks of immersion into two types of mouthwashes (Listerine with alcohol and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref