Preferred Language
Articles
/
jkmc-808
Comparative study on Various Tube Voltages and Contrast Media Doses in CT Pulmonary Angiography to detect Pulmonary Thromboembolism
...Show More Authors

Background: Lowering the amount of iodinated contrast material and tube voltage may increase pulmonary artery opacification and thrombus identification without compromising picture quality.

Objectives: To explore the efficiency of using lower tube voltage and a lower contrast medium dose for conducting computed tomography for pulmonary angiography (CTPA) aiming to increase its accuracy in detecting pulmonary thromboembolism (PTE).

Subjects and Methods:100 patients scheduled for CTPA with a preoperative diagnosis of PTE were grouped into two: group A, (50 patients) got 1 mL/kg at 120 kV and group B, (50 patients) received 0.5 mL/kg at 80 kV.The technique of bolus tracking was implemented.Values of midpoint of multiple pulmonary artery divisions were used to assess attenuation.Significant values are those that exceed 300 Hounsfield units (HU). The dosage of radiation received by the patient, defined as the effective dose, was compared between groups.

Results: Total mean attenuationdata for the pulmonary arteries have shown to be substantially greater in group-B compared to group-A (39110.4HU vs. 335.97.9HU, P=0.001). Moreover, total dose length product (DLP) values were substantially lower in group-B (934.9 mGy.cm vs. 384.443 mGy.cm, P=0.001). While effective dose values have shown to be significantly lower in group-B (2.90.3 mSv vs. 13.21.8 mSv, P 0.001).

Conclusion: Low-kilovoltage technique and low quantity of iodinated contrast are useful in conducting (CTPA) with high accuracy in detection of pulmonary thromboembolism.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
A Comparative Study of Various Intelligent Algorithms Based Nonlinear PID Neural Trajectory Tracking Controller for the Differential Wheeled Mobile Robot Model
...Show More Authors

This paper presents a comparative study of two learning algorithms for the nonlinear PID neural trajectory tracking controller for mobile robot in order to follow a pre-defined path. As simple and fast tuning technique, genetic and particle swarm optimization algorithms are used to tune the nonlinear PID neural controller's parameters to find the best velocities control actions of the right wheel and left wheel for the real mobile robot. Polywog wavelet activation function is used in the structure of the nonlinear PID neural controller. Simulation results (Matlab) and experimental work (LabVIEW) show that the proposed nonlinear PID controller with PSO
learning algorithm is more effective and robust than genetic learning algorithm; thi

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun May 15 2022
Journal Name
Bionatura
Comparative anatomical study to skeleton for same species of Turtles in Iraq
...Show More Authors

Bones were recorded in the skeleton of some species of Iraqi turtle Mauremys rivulata; the objectives of this study came in light of current conditions, environmental developments, talents and techniques of biological studies taking place in the country, need for an anatomy guide in river turtles of Iraqi species, to identify all kinds of similarities and differences with their preaching, this work or study has become written in response to those modern needs. It is designed to be one of the resources for those interested in biological studies, beginners or professionals, and veterinarians, distinguishing them from marine and global species. Turtles were dissected in the laboratories of the Research Center and Museum of Natural Hist

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
A comparative Study to calculate the Runs Property in the encryption systems
...Show More Authors

Cryptographic applications demand much more of a pseudo-random-sequence
generator than do most other applications. Cryptographic randomness does not mean just
statistical randomness, although that is part of it. For a sequence to be cryptographically
secure pseudo-random, it must be unpredictable.
The random sequences should satisfy the basic randomness postulates; one of them is
the run postulate (sequences of the same bit). These sequences should have about the same
number of ones and zeros, about half the runs should be of length one, one quarter of length
two, one eighth of length three, and so on.The distribution of run lengths for zeros and ones
should be the same. These properties can be measured determinis

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 06 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Building HEC-RAS model to detect the areas of Water Cycle Interruption in river stream and their sections
...Show More Authors

The purpose of this paper is to build a simulation model by using HEC-RAS software to simulate the reality of water movement in the main river of Basra City (South of Iraq) which is known as Siraji-Khoura River. The main objective of the simulation is to detect areas where the water cycle is interrupted in some stations of the river stream, as this river has become an outlet for the disposal of sewage, leading to pollution and causing weakness in some sections of the river & obstructing the water cycle that takes place between this river and Shatt al – Arab river. A field survey data of the river and its banks were adopted to derive the grades, longitudinal and cross sections of the river, these data included three-dimensional coordinates

... Show More
View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Different Techniques to Detect Recurrent Carious Lesion Around Amalgam Filling
...Show More Authors

Abstract Background: This in-vitro study was to evaluated bitewing radiograph and tactile examination for detection secondary caries adjacent to amalgam restorations. Material and method: Sixty primary extracted molars with class I and class II amalgam restorations were selected from children, and examined by bitewing radiographs were taken by using film holders and interpreted on a backlit screen without magnification. Then, we used tactile examination with blunt probe. Result: The result of this study showed that the best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve and the sensitivity, specificity and accuracy of the techniques were calculated for enamel (

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 06 2022
Journal Name
International Journal Of Professional Business Review
A Comparative Study to Reveal Earnings Management in Emerging Markets: Evidence from Tunisia and Iraq
...Show More Authors

Purpose: The purpose of the study is to compare and evaluate Earnings Management in Tunisia and Iraq.   Theoretical framework: Earnings Management is an important topic that has been studied by a significant number of researchers, as well as those who are interested in the accounting profession. Earnings Management has gotten a lot of attention from academics, professionals, and other interested parties in recent years (e.g. Kliestik et al., 2020; Rahman et al., 2021; Gamra &Ellouze, 2021)   Design/methodology/approach: The sample includes ten banks listed on the Bourse of Tunisia and Iraq Stock Exchanges for the year 2017. We have used a model of Kothari et al., (2005) as a tool to measure Earnings Management in both mark

... Show More
View Publication
Scopus (24)
Crossref (3)
Scopus Crossref
Publication Date
Mon May 11 2026
Journal Name
Journal Of Baghdad College Of Dentistry
A comparative study to evaluate the shear bond strength of different resin sealers to dentin (An in vitro study)
...Show More Authors

Background: One of the major problems in endodontics is micro-leakage of root canal fillings which might contribute to the failure of endodontic treatment. To avoid this problem, a variety of sealers have been tested. The objective of this, in vitro, study was to evaluate the shear bond strength of four resin based sealers (AH plus, silver free AH26, RealSeal SE and Perma Evolution permanent root canal filling material) to dentin. Materials and Methods: Forty non-carious extracted lower premolars were used. The 2mm of the occlusal surfaces of teeth were sectioned, to expose the dentin surface. The exposed dentin surfaces of teeth were washed with 5ml of 2.5% NaOCl solution followed by 5ml of 17 % EDTA then rinsed by deionized water to remov

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 30 2023
Journal Name
The International Tinnitus Journal
Adenoidectomy and Endoscopic Myringotomy with and without ventilation tube insertion for Treatment of Otitis Media with Effusion in 6-12 years old Children
...Show More Authors

View Publication Preview PDF
Scopus (3)
Crossref (5)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Computer Networks, Big Data And Iot
A Comprehensive Study of Various DC Faults and Detection Methods in Photovoltaic System
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of General Medicine
The Value of Longitudinal Strain versus Coronary Angiography in Detection of Coronary Artery Disease
...Show More Authors

Aims: The aim of this study was to evaluate the value and accuracy of longitudinal strain in detection of coronary artery disease compared to coronary angiography. Results: The left ventricular longitudinal strain-speckle tracking showed evidence of stenosis of left anterior descending artery, circumflex artery and right coronary artery in (86.1%), (76.4%), and (84.7%) respectively. For the stenosis in left anterior descending artery, the current study showed that the longitudinal strain was a good predictor for presence of significant stenosis with a sensitivity of (93.8%), specificity (75%) and accuracy (91.7%) compared with coronary angiography. For the stenosis in right coronary artery, the left ventricular longitudinal strain had

... Show More
View Publication
Crossref (2)
Crossref