Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 08 2024
Journal Name
Babylon: Abjad Publising House
“Translation is the Art of Negotiating with Words”, in Hassad aS-Sineen(Harvest of Years): Essays in Teaching Translation
...Show More Authors

Publication Date
Wed Dec 30 2015
Journal Name
College Of Islamic Sciences
Making up missed fasts Terms and conditions
...Show More Authors

The obligatory duty must be fulfilled for attachment to the discharge, whatever the reasons for the missingness, whether it is left by mistake or omission or deliberate, whether with or without excuse. What is likely in this research to spend Ramadan on laxity.
The one who delayed making up Ramadaan fasts until he realized another Ramadaan, fasted the second and spent the first after him, and no ransom on him, either with an excuse or without an excuse.

View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
A three-stage blumlein-circuit to generate transversely excited atmospheric nitrogen laser by using three spark gaps
...Show More Authors

In this research constructed N2 laser system by use developed method of electric discharge. In this method used four step of electric discharge by using four capacitors, three spark gaps, high tension power supply varying in range from 12kV to 24 kV and three resistors, this method called three stage blumlein circuit. The breakdown time delay of these parallel spark gaps cement strong ultraviolet preionization in the laser channel, thus the result of these amendments the laser output is many doubled and is more increasing than that obtained using the one and two stage blumlein circuits. This system has been designed and operated to give pulse laser with wavelength at 337.1 nm. This laser system can operate without mirrors and optical res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 02 2020
Journal Name
Journal Of Applied Research In Higher Education
Proposal of a guide for talent evaluation and management based on a qualitative and three-staged approach
...Show More Authors
Purpose

The key objective of the study is to understand the best processes that are currently used in managing talent in Australian higher education (AHE) and design a quantitative measurement of talent management processes (TMPs) for the higher education (HE) sector.

Design/methodology/approach

The three qualitative multi-method studies that are commonly used in empirical studies, namely, brainstorming, focus group discussions and semi-structured individual interviews were considered. Twenty-three individuals from six Australian universities parti

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Advances In Science, Technology & Innovation
Producing a Three Dimensional Model for the University of Baghdad Campus Using GIS Environment
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
Measurement of Pollution Level with Particulate Matter in Babylon Concrete Plant and Evaluation of Oxidative Stress and Hematological Profile of Plant Workers
...Show More Authors

The impact of exposure to different sizes of particulate matter (PM1, PM2.5, PM7, and PM10) was evaluated in  Babylon concrete plant workers who had been exposed to concrete dust for at least 10 years.  The effects of  these particles on the hematological parameters, malondialdehyde (MDA) levels, and  antioxidant enzymes (catalase and glutathione peroxidase ) were examined. The results exhibited that the levels of PM2.5 and PM10 were higher than the acceptable limits approved by the National Ambient Air Quality Standards (NAAQS). The blood parameters, namely white blood cells (WBC), red blood cell (RBC) and platelets counts, demonstrated non-significant differences between workers exposed to the PM as compared to the control gro

... Show More
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Thu Sep 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mathematical Model, Simulation and Scale up of Batch Reactor Used in Oxidative Desulfurization of Kerosene
...Show More Authors

   In this paper, a mathematical model for the oxidative desulfurization of kerosene had been developed. The mathematical model and simulation process is a very important process due to it provides a better understanding of a real process. The mathematical model in this study was based on experimental results which were taken from literature to calculate the optimal kinetic parameters where simulation and optimization were conducted using gPROMS software. The optimal kinetic parameters were Activation energy 18.63958 kJ/mol, Pre-exponential factor  2201.34 (wt)-0.76636. min-1  and the reaction order 1.76636. These optimal kinetic parameters were used to find the optimal reaction conditions which

... Show More
View Publication Preview PDF
Crossref (19)
Crossref
Publication Date
Mon May 23 2022
Journal Name
The International Journal Of Artificial Organs
Quantitative analysis and control of the torque profile of the upper limb using a kinetic model and motion measurements
...Show More Authors

This paper investigates a new approach to the rapid control of an upper limb exoskeleton actuator. We used a mathematical model and motion measurements of a human arm to estimate joint torque as a means to control the exoskeleton’s actuator. The proposed arm model is based on a two-pendulum configuration and is used to obtain instantaneous joint torques which are then passed into control law to regulate the actuator torque. Nine subjects volunteered to take part in the experimental protocol, in which inertial measurement units (IMUs) and a digital goniometer were used to measure and estimate the torque profiles. To validate the control law, a Simscape model was developed to simulate the arm model and control law in which measurem

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Estimation of vitamin E level and its relation to lipid profile in patients with type II Diabetes Mellitus
...Show More Authors

Background: Type 2 diabetes mellitus (T2DM) is considered a global disease as it affects over 150 million people worldwide, a number that is supposed to be doubled by 2025. High glucose levels, in vitro, appear to raise the extent of LDL oxidation, and glycated LDL is more prone to oxidative modification.Objective: To investigate the relationship between serum level of vitamin E and lipid profile in patients with type II DM.Methods: This study involved 28 patients suffering from type II DM diagnosed 1-4 years ago and with age ranged from 17 -60 years old, with different residence around Basra ; In addition to 56 apparently healthy persons matched in age and sex to the patients as a control group. The medical histories were taken and Gene

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2017
Journal Name
Professional Safety
Six Sigma & Construction Safety
...Show More Authors