Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 12 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Using Phone Calls to Promote Community Pharmacist Counselling during COVID-19 Pandemic in Baghdad, Iraq
...Show More Authors

Drug consultation is an important part of pharmaceutical care. mobile phone call or text message can serve as an easy, effective, and implementable alternative to improving medication adherence and clinical outcomes by providing the information needed significantly for people with chronic illnesses like diabetes and hypertension particularly during pandemics like COVID-19 pandemic.

View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Sep 14 2025
Journal Name
Razi Medical Journal
Unexpected Vascular Anomaly; Right Subclavian-Pulmonary Artery Connection Unraveled during Routine PDA Closer; Case Report
...Show More Authors

Publication Date
Mon Oct 01 2018
Journal Name
Plant Archives
A comparative anatomical study of three types of gymnospermplantscycasrevoluta,thujaoreintalisand cupressussemperviens
...Show More Authors

Scopus
Publication Date
Thu Aug 04 2022
Journal Name
Contemporary Nurse
ICU nurses’ safety performance related to respect for safety and management commitment: A cross-sectional study
...Show More Authors

View Publication
Scopus (13)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The Exchange Rate of Iraqi Dinar between De facto Regime and De jure Regime in the Iraq during (2004-2012)
...Show More Authors

         The understanding exchange rate policy is fundamental in order to identify the mechanism by which works out macroeconomic, And the vital for macroeconomic analysis and empirical work to differentiate between the de facto regimes and de jure regimes, Where the proved surveys and studies issued by the international monetary fund that there is divergence between the de facto regime (Regime of exchange applied by the country actually) and between the de jure regime (Regime de jure through the documents and formal writings of officials of the central bank), And launched studies on the de facto regime (Being a the basis of evaluating monetary policy) Stabilized (peg-like)arrangements or

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of Food Process Engineering
Artificial intelligence‐based modeling of novel non‐thermal milk pasteurization to achieve desirable color and predict quality parameters during storage
...Show More Authors
Abstract<sec><label></label><p>This study proposed using color components as artificial intelligence (AI) input to predict milk moisture and fat contents. In this sense, an adaptive neuro‐fuzzy inference system (ANFIS) was applied to milk processed by moderate electrical field‐based non‐thermal (NP) and conventional pasteurization (CP). The differences between predicted and experimental data were not significant (<italic>p</italic> > 0.05) for lightness (<italic>L</italic>*), redness‐greenness (<italic>a</italic>*), yellowness‐blueness (<italic>b</italic>*), total color differences (∆<italic>E</italic>), hue angle (<italic>h</italic></p></sec> ... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Measuring Lower Uterine Segment Thickness Using Abdominal Ultrasound to Predict Timing of Cesarean Section in Women with Scarred Uterus at Elwiya Maternity Teaching Hospital
...Show More Authors

Background: Ultrasonography has been used to examine the thickness of the lower uterine segment in women with previous cesarean sections in an attempt to predict the risk of scar dehiscence during subsequent pregnancy. The predictive value of such measurement has not been adequately assessed. Objectives: To correlate lower uterine segment thickness measured by trans abdominal ultrasound in pregnant women with previous cesarean section with that measured during cesarean section by caliper and to find out minimum lower uterine segment thickness indicative of integrity of the scar.Methods: A prospective observational study at Elwyia Maternity Teaching Hospital, from January 2011 to January 2012. A total of 143 women were enrolled in the stu

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 03 2018
Journal Name
Al-academy
Dramatic Utilization of Close-up in Horror Movies
...Show More Authors

A cinematic shot is the basis of the film, regardless of the size, angle, or motion of this shot. However, the size of the footage and the process of showing or hiding the scene or cinematic personality has a certain speciality   related to the nature of cinematic treatment and the type of the movie especially those characterized by the employment of the close-ups to induce   ambiguity or spread the mental image of the dramatic events and this relationship between the close-up and horror films is what prompted the researcher to identify the title of the search as follows:

 

Dramatic utilization of Close-Up in Horror Movies

The research is divided as follows:

The methodological fram

... Show More
View Publication
Crossref
Publication Date
Sat Oct 05 2019
Journal Name
Journal Of Engineering And Applied Sciences
Enhanced Dielectrically Properties of Up-Pistachio Peel Composites
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Clinical Outcome of Invasive Pituitary Prolactinomas Treated with Cabergoline
...Show More Authors

Background: Treatment of invasive prolactinoma, which has several characteristics including invasive growth into cavernous sinuses and formation of giant adenomas compressing adjacent neural structures, resulting in neurological dysfunction, has been very challenging. There are relatively few reports available describing long-term treatment outcome.

Aims of the study: In this study we evaluate the results of cabergoline administration as initial treatment during 4 years follow up period.

Methods: We prospectively categorized 36 patients into four groups according to the results of 3 months of cabergoline treatment: group 1, tumor volume reduction (TVR) ˃25% with normaliz

... Show More
View Publication Preview PDF