Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Communications In Mathematical Biology And Neuroscience
The impact of fear and harvesting on plankton-fish system dynamics incorporating harmful phytoplankton in the contaminated environment
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
The role of monetary policy in achieving economic stability and growth in Iraq for the period (2004-2011)
...Show More Authors

The objective of this research to analyze the effectiveness of monetary policy in achieving economic stability and growth for the period 2004-2011 ،This period of time saw a fundamental shift in monetary policy after the issuing new law the Central Bank of the full independence of the monetary authority ،This is Prompt the monetary authority to bring about a change in the philosophy and objectives and the tools used to achieve the desired  goals ،Which give them the ability to control the size of the money supply and to achieve price stability Indeed، Monetary policy has been able to achieve the golden triangle of economic stability ،Consisted of staff، exchange rate stability and low and stable general level of prices

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Tue Aug 27 2024
Journal Name
Tem Journal
Preparing the Electrical Signal Data of the Heart by Performing Segmentation Based on the Neural Network U-Net
...Show More Authors

Research on the automated extraction of essential data from an electrocardiography (ECG) recording has been a significant topic for a long time. The main focus of digital processing processes is to measure fiducial points that determine the beginning and end of the P, QRS, and T waves based on their waveform properties. The presence of unavoidable noise during ECG data collection and inherent physiological differences among individuals make it challenging to accurately identify these reference points, resulting in suboptimal performance. This is done through several primary stages that rely on the idea of preliminary processing of the ECG electrical signal through a set of steps (preparing raw data and converting them into files tha

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sat Sep 30 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of applying assurance engagements according to the international standard IASE (3402) in enhancing the auditing action
...Show More Authors

Abstract:
                The research seeks to explain the role of the international auditing standard (3402) in the auditor's procedures, where the importance of the research stems from the adoption of international auditing standards in the Iraqi environment, including the standard (3402) of assurance engagements that the external auditor performs by submitting reports on the design of control tools and their operational effectiveness in a service facility that provides the beneficiaries with a service. To provide useful information for service organizations The control tools are of great benefit in rationalizing decisions, and many recommen

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Batch and Flow-Injection Spectrophotometric Determination of Procaine HCl in Pharmaceutical Preparations Via Using Diazotization and Coupling Reaction
...Show More Authors

Simple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. A

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 10 2017
Journal Name
Al–bahith Al–a'alami
Qualitative Research in Public Relations An Analytical: Study of Public Relations› Researches in Iraq from 1989 to 2016
...Show More Authors

In the mist of developments in the course of scientific research in general and humanities in particular and the accompanying changes in the visions and policies inspired by the need for these sciences to follow the qualitative methods in dealing with many of the topics or problems that require for their solution to obtain qualitative information which can be provided by resorting to quantitative research. Therefore, a new trend has emerged in many public relations› researchers who believe that qualitative research methods should be used by establishing scientific foundations and methodological classification based on the use of these methods and determining the nature of the subjects applied in them to reach results that are character

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Hard Chromium Electroplating and Improvement the Properties by the Thermo Chemical Treatments (Solid Carburizing) of Low Carbon Steel
...Show More Authors

In this research the hard chromium electroplating process, which is one of the common methods of overlay coating was used, by using chromium acid as source of chromium and sulphuric acid as catalyst since the ratio between chromic acid and sulphuric acid is (100 : 1) consequently. Plating process was made by applying current of density (40 Amp / dm2) and the range of solution temperature was (50 – 55oC) with different time periods (1-5 hr). A  low carbon steel type (Ck15) was used as substrate for hard chromium electroplating. Solid carburization was carried out for hard chromium plating specimen at temperature (925oC) with time duration (2 hr) to be followed with quenching and tempering

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Marine And Petroleum Geology
Geophysical evidence for structurally-controlled, authigenic carbonate cementation in the Laminaria High, Bonaparte basin, Northwest Shelf of Australia
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Iraqi Journal Of Applied Physics
Structural and Electrochemical Characterization of ITO Electrode Modified by f- MWCNT/graphene/polypyrrole Nanocomposite Decorated by Gold Nanoparticles
...Show More Authors

There is currently a pressing need to create an electro-analytical approach capable of detecting and monitoring genosensors in a highly sensitive, specific, and selective way. In this work, Functionalized Multiwall Carbon Nanotubes, Graphene, Polypyrrole, and gold nanoparticles nanocomposite (f-MWCNTs-GR-PPy-AuNP) were effectively deposited on the surface of the ITO electrode using a drop-casting process to modify it. The structural, morphological, and optical analysis of the modified ITO electrodes was carried out at room temperature using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) images, atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectra. Cyclic voltammetry (CV) and electrochemi

... Show More
View Publication
Publication Date
Thu Aug 28 2014
Journal Name
Iraqi National Journal Of Chemistry The Editorial Board
The New C-2,C-3 Substituted Heterocyclic Derivatives of L-Ascorbic acid: Synthesis, Characterization, and Bacterial Activity
...Show More Authors

New Schiff bases derivatives [IV]a-e is prepared via condensation of Derythroascorbic acid with p-substituted aldehydes in dry benzene. To obtain these derivatives, the 5,6-O-isopropylidene-L-ascorbic acid[I] was chosen as starting material, compound prepared from the reaction of L-ascorbic acid as starting material. Compound[I] was prepared from the reaction of L-ascorbic acid with dry acetone in the presence of hydrogen chloride. The esterification of hydroxyl groups at C-2 and C-3 positions with excess ofethyl α –chloroacetate in the presence of sodium acetate produce acorresebonding ester [II] , which was condensed with hydrazine hydrate to give new hydrazide [III] . The new Schiff bases [IV]a-e were synthesized by reaction of acid h

... Show More