Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Strengthening of Reinforced Concrete T- Section Beams Using External Post-Tensioning Technique
...Show More Authors

This research is carried out to investigate the externally post-tensioning technique for strengthening RC beams. In this research, four T-section  RC beams having the same dimensions and material properties were casted and tested up to failure by applying two mid-third concentrated loads. Three of these beams are strengthened by using external tendons, while the remaining beam is kept without strengthening as a control beam. Two external strands of 12 mm diameter were fixed at each side of the web of the strengthened beams and located at depth of 200 mm from top fiber of the section (dps). So that the depth of strands to overall depth of the section ratio (dps

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 22 2025
Journal Name
Journal Of Composites And Biodegradable Polymers
Experimental Behavior of One-Way RC Ultra-Thin Slabs Retrofitted with Post-Installed NSM CFRP Rods
...Show More Authors

This study evaluates the flexural behavior of ultra-thin (50 mm) one‑way reinforced‑concrete (RC) slabs retrofitted with near‑surface mounted (NSM) carbon‑fiber‑reinforced polymer (CFRP) rods under quasi‑static loading. T300‑grade CFRP rods (≈4 mm diameter) were bonded in pre‑cut 7 mm × 7 mm grooves using a two‑part epoxy. As a proof-of-concept experimental baseline, three simply‑supported specimens (1000 mm × 500 mm × 50 mm) were tested in a six‑point bending configuration (four applied loads + two reactions): two conventional controls and one strengthened slab. A load‑control rate of ~15 kN/min was applied; the controls were cycled twice and the strengthened slab four times. Relative to the average of

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Dec 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Thermal Conductivity Characteristics of Polymer composites Based on Polyethylene Wastes Filled with Post-Industry Wood Wastes
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Nov 01 2013
Journal Name
Iraqi Postgraduate Medical Journal
Post Hair Epilation Acneiform Eruption Among Females
...Show More Authors

KE Sharquie, HR Al-Hamami, IK Sharquie, AA Noaimi, HM Al-Karawy, Iraqi Postgraduate Medical Journal, 2013

View Publication
Publication Date
Sat Dec 30 2023
Journal Name
Al-kindy College Medical Journal
Health System in Iraq Post 2003 War
...Show More Authors

Background: War represents a major human crisis; it destroys communities and results in ingrained consequences for public health and well-being

Objective: We set this study to shed light on the public health status in Iraq after the successive wars, sanctions, sectarian conflicts, and terrorism, in light of certain health indicators.

Design: The primary source of data for this analysis comes from the Iraqi Ministry of Health, and The World Health Organization disease surveillance.

Results: Most of the morbidity indicators are high, even those that are relatively declining recently, are still higher than those repor

... Show More
View Publication Preview PDF
Scopus (24)
Crossref (15)
Scopus Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Pyogenic Discitis in Female after Delivery and Pelvic Surgery
...Show More Authors

Background: Pyogenic discitis most frequently occurs
after home delivery, hemorridectomy, and dilatation and
curettage. Discitis is generally due to blood borne bacterial
invasion of the disc from adjacent end-plate via
communicating vessels. Infective discitis remains an
uncommon, but potentially serious cause for back pain.
Delayed diagnosis can occur and a high index of suspicion
may occur.
Methods: The study included 30 patients suffering from
localized low back pain with limitation of movement.
Diagnosis was made by history, physical examination and
investigation mainly E.S.R and MRI.
Results: 50.3% of patient with discitis had a history of
vaginal delivery, 15% had a history of hemorridectomy

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Combination of FDM 3D Printing and Compressed Tablet for Preparation of Baclofen as Gastro-Floating Drug Delivery System (Conference Paper )#
...Show More Authors

This study aimed to develop an oral drug delivery system for gastro-retentive sustained drug release of baclofen by using a 3D printed capsular device since baclofen has a short half-life of 2.5 to 4 hours and has a narrow absorption window. Firstly sustained-release tablets of baclofen were formulated through the hot-melt extrusion of various thermoplastic polymers and direct compression of the extrudate, then a capsular device was designed and 3D printed to contain two air pockets to enable floating of the device and has four windows for drug release.

3D printing of the capsular device was done by an FDM printer using biodegradable PLA filament, and the sustained release tablets were inserted into the device to allow the medici

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
International Review On Modelling And Simulations (iremos)
Inexpensive DC to AC Inverter Device for Artificial Saline Soils Resistivity Analysis
...Show More Authors

In aired and semiarid areas like Iraq, saline soil may be considered one of the major concerns. In addition to environmental effects, they may produce significant geotechnical hazards that could interrupt the structure stability depending on the salt type and its concentration. So, it is crucial to identify the degree of the soil salinity with a proper tool for getting a qualified assessment and consequently offering a suitable treatment. In this paper, the electrical resistivity technique has been employed to detect the degree of soil salinity by considering a new electronic system. The system used a single-phase Direct Current (DC) to Alternating Current (AC) inverter accompanied by a transformer. Natural soils became artificially saline

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Mar 01 2015
Journal Name
International Journal Of Engineering And Innovative Technology
White Light Generation by Electroluminescence for ZnO Nanoparticle –Organic Hybrid Junction Device
...Show More Authors

ZnO organic hybrid junction (electroluminescence EL device) was fabricated using phase segregation method. ZnO-nanoparticle (NPs) was prepared as a colloidal by self–assembly method of Zinc acetate solution with KOH solution. Nanoparticle is employed to form organic-inorganic hybrid film and generate white light emission, while N,N’–diphenyl-N,N’ –bis(3-methylphenyl)-1,1’-biphenyl 4,4’-diamine (TPD) and polymethyl methacrylate (PMMA) are adopted as the organic matrices. ZnO NPs was used to fabricate TPD: PMMA: ZnO NPs hybrid junction device. The photoluminescence (PL) and electroluminescence (EL) spectra of the TPD: PMMA: ZnO NPs hybrid device provided a broad emission band covering entirely the visible spectrum (∼350-∼700

... Show More
View Publication
Publication Date
Fri Jul 24 2020
Journal Name
Al-kindy College Medical Journal
Speculations of Immunotherapy in COVID-19 Patients with Practical Applications During Childhood and Pregnancy
...Show More Authors

The rapid spread of novel coronavirus disease(COVID19) throughout the world without availablespecific treatment or vaccine necessitates alternativeoptions to contain the disease. Historically, childrenand pregnant women were considered high-riskpopulation of infectious diseases but rarely have beenspotlighted nowadays in the regular COVID-19updates, may be due to low global rates of incidence,morbidity, and mortality. However, complications didoccur in these subjects affected by COVID-19. Weaimed to explore the latest updates ofimmunotherapeutic perspectives of COVID-19patients in general population and some added detailsregarding pediatric and obstetrical practice.Immune system boosting strategy is one of therecently emerging issue

... Show More
View Publication
Crossref (1)
Crossref