Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 30 2025
Journal Name
Surabaya Medical Journal
Exploring Dental Students' Perspectives: The Impact of Hybrid Learning in a Post-Pandemic World
...Show More Authors

Background: The pandemic crisis prompted the world to adopt unexpected approaches to continue life as normally as possible. The education sector, including professors, students, and the overall teaching system, has been particularly affected. Objective: This study seeks to evaluate the benefits, challenges, and strategies related to COVID-19 from the perspectives of college students, particularly those in higher education in Iraq. Method: The online survey questionnaire was distributed via Google Forms and specifically aimed at undergraduate dental students. Results: A total of 348 students participated in the survey. There was a significant correlation (P > 0.01) between student satisfaction with hybrid learning and their experi

... Show More
View Publication
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Perinatal out come of Breech Presentation in the Presentation in the Pretext Mode of Delivery
...Show More Authors

Objectives: To choose the best mode of delivery
for term, frank or complete, breech presentation
through studying the perinatal outcome of each mode of
delivery decided when managing a group of pregnant
ladies presented with breech delivery in our centre.
Methods: One hundred and fifty pregnant ladies
presented at term with singleton, frank or complete,
breech presentation for delivery in our centre during the
period from May 2004 toAugust 2005.
Mode of delivery, parity, gestational age, maternal age,
maternal medical illness, and birth weight where the
variables that have been tested in each delivery
included in the study to verify their relationship to
perinatal outcome.
Results: No significant

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2019
Journal Name
Karbala Journal Of Physical Education Sciences
Effect of use a designed device to develop some biochemical variables for rear vault dismount with one-half twist on parallel bars in gymnastics
...Show More Authors

The research included five sections containing the first section on the introduction o research and its importance and was addressed to the importance of the game of gymnastic and skilled parallel bars effectiveness and the importance of biochemical variables, either the research problem that there is a difference in learning this skill and difficulty in learning may be one of the most important reasons are falling and injury Has a negative impact on the performance and lack of sense of movement of is one of the obstacles in the completion of the skill and the goal of research to design a device that helps in the development of biochemical changes to skill of rear vault dismount with one-half twist on parallel bars in gymnastics . And the n

... Show More
Preview PDF
Publication Date
Sat Jun 25 2022
Journal Name
International Journal Of Drug Delivery Technology
Evaluation of IL17A, FGF21 and CXC12 in Post-menopause Iraqi Sample with Osteoporosis and Osteopenia
...Show More Authors

Osteoporosis (OP) is a systemic skeletal disorder that is characterized by reduced bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. The most frequent osteoporotic fractures are fractures of the hip, wrist, and spine. The exact causes of OP are still unknown; several factors contribute to the disorder. Subjects and Methods: This study consists of patient groups, this group (Group A) was composed of 80 postmenopausal women with OP and osteopenia and the patient group was subdivided into two group; First group (GroupA1) was composed of 50 postmenopausal women with OP and the second group (Group A2) composed of (30) Postmenopausal Women with oste

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Mon Sep 01 2025
Journal Name
Civil Engineering Journal
Pre- and Post-Cracking Resistance of Steel Fiber Reinforced Concrete Flexural Members with GFRP Bars
...Show More Authors

This research investigates the pre- and post-cracking resistance of steel fiber-reinforced concrete specimens with Glass Fiber Reinforced Polymer (GFRP) bars subjected to flexural loading. The purpose is to modify the ductility and cracking resistance of GFRP-reinforced beams, which are prone to early cracking and excessive deflections instigated by the low modulus of elasticity of GFRP. Six self-compacting concrete specimens (1500×240×200 mm), incorporating steel fibers of two lengths (25 mm and 40 mm) with varying distribution depths, were tested to assess their structural performance. The results indicate significant enhancements in cracking resistance, stiffness, energy absorption, ductility, and flexural strength. Tested beam

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Jun 05 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and characterization of timed drug delivery system of sumatriptan using natural polymers
...Show More Authors

Pulsatile drug delivery systems are time-controlled dosage forms which are designed to release the active pharmaceutical ingredient after a predetermined lag time to synchronize the disease circadian rhythm. A migraine shows circadian rhythm with a marked increase in attacks between 6 a.m. and 8 a.m.

Sumatriptan is a selective agonist at serotonin (5-Hydroxy tryptamine1  (5-HT1))receptors, is an effective treatment for acute migraine attacks.

The aim of this work is to prepare time-controlled press-coated tablet with a lag time of 5.45 hrs.

Six formulas of fast dissolving core tablets and three formulas of press-coated tablets were prepared by using direct compression method using different variables to prepa

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 17 2022
Journal Name
Al–bahith Al–a'alami
Post-interactive communication A study to build a model for the flow of communication in social networking sites
...Show More Authors

The issue of the research lies in the non-representation of the models developed for the communication process in the interaction and networking processes through social media, as the research sought to build a network model of communication according to the specific data and features of social media platforms in order to reach a special generalization to understand how the process of networking operates in cyberspace.

The researcher followed the analytical survey approach as she described the communication models outwardly in order to be able to build a networked communication model that represents the flow of post-reactive communication. Therefore, it has been named "Nebula - Sadeem" after the concept of post-space and cosmic g

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Engineering
The Behavior of the Al-Kadhim Minaret during Earthquakes: A Virtual Study
...Show More Authors

The study focuses on the causes of minaret tilting as well as possible solutions. The major aims of this study are to improve knowledge of historical tall structure stability and rehabilitation operations using the finite element approach to model the soil and minaret (PLAXIS 3D 2020), a platform for computational soil investigation and modeling. The numerical analysis aims to identify stresses, settlement, and deformation of the soil and minaret in various scenarios like Earthquakes, explosions, and winds. The simulation of the problem by the PLAXIS 3D revealed that the greatest lateral displacement computed at the Top Minaret is 5.5 cm, and the greatest vertical movement is calculated to be 3 cm. Seismic settlement is the effect of ear

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Myomectomy During Early Pregnancy
...Show More Authors

Myoma is a common benign uterine tumor; therefore
it is common in pregnancy. One in ten women will
have complications related to myoma in pregnancy.
Few treatment options are available during pregnancy,
conservative treatment with analgesia, reassurance and
supportive therapy is almost always adequate but in
carefully selected patients, myomectomy has been
performed successfully without jeopardizing
pregnancy outcome. The usual indications for surgery
during pregnancy include torsion of pedunculated
uterine myoma and obstructed labor, surgical
intervention during pregnancy is occasionally
necessary in uncommon cases of intractable pain.
19 years old lady presented with intractable lower
abdominal

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Cytokine
Evaluation of IL-8, nitric oxide and macrophage inhibitory factor as clinical circulatory markers in patients with cutaneous leishmaniasis, before and during sodium stibogluconate treatment
...Show More Authors

The clinical spectrum of cutaneous leishmaniasis (CL), an intracellular parasitic pathogen, ranges from a single sore healing to chronic crusty lesions with a manifestation of treatment resistance. The complicated interaction between Leishmania bodies and the early immune response, including innate and adaptive mechanisms, determines the evolution of nodules. This study examined the levels of the chemoattractant interleukin 8 (IL-8), pro-inflammatory nitric oxide (NO), and immunoregulatory macrophage inhibitory factor (MIF) in the serum of subjects recently diagnosed with cutaneous leishmaniasis, in parallel with patients being monitored during consecutive sodium stibogluconate (Pentostam) treatment. A total of 161 serum samples of newly di

... Show More
View Publication
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref