|
Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice. Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospital in Baghdad, Iraq from the 1st of August to the 30th of October 2018. Transcutaneous bilirubin measurement on forehead and upper sternum was done by JM 103 Minolta Air shields bilirubinometer. Total serum bilirubin was measured by APEL BR 501 BILIRUBIN METER. Data entered & analyzed using SPSS 20 computer software. Means, frequencies, cutoff values, sensitivity & specificity were calculated. Results: The mean age, gestational age & birth weight were (6.3±4.3 days), (36.9±2.1 weeks) and (2.7±0.6 Kg) respectively. Mean total serum bilirubin, transcutaneous chest & forehead bilirubin levels were 12.6±4.2 mg/dl, 11.8±3.8 mg/dl & 11.2±3.9 mg/dl respectively. Mean total serum bilirubin was significantly higher than transcutaneous chest and forehead bilirubin. Cutoff values of transcutaneous chest & forehead bilirubin levels were [(9 mg/dl) with sensitivity (95.4%) & specificity (86.4%)] and [(8.2 mg/dl) with sensitivity (94.7%) & specificity (86.4%)] respectively. |
The monthly time series of the Total Suspended Solids (TSS) concentrations in Euphrates River at Nasria was analyzed as a time series. The data used for the analysis was the monthly series during (1977-2000).
The series was tested for nonhomogenity and found to be nonhomogeneous. A significant positive jump was observed after 1988. This nonhomogenity was removed using a method suggested by Yevichevich (7). The homogeneous series was then normalized using Box and Cox (2) transformation. The periodic component of the series was fitted using harmonic analyses, and removed from the series to obtain the dependent stochastic component. This component was then modeled using first order autoregressive model (Markovian chain). The above a
... Show MoreTo evaluate and compare serum Leptin hormone level between Iraqi male & female and the relation between this hormone & BMI in these two groups.
A total of 44 normal male & female subjects were included in this study
{Group 1 : 22 female } , { Group 2 : 22 male}.
Serum Leptin hormone ,BMI &fasting blood glucose were measured for both groups.
Serum Leptin level in group 1 was (8.82 + 2.9 μg/L) where as in group 2 it was (4.65 + 3.2 μg/L) . These changes were statistically significant. Fasting blood glucose levels were technically within the normal value (
... Show MoreOvarian cancer has a high mortality and delayed diagnosis. Several immunological alterations take place during ovarian carcinogenesis, and can be of value in the surveillance of the diseases. This research was conducted to evaluate serum immunoglobulin levels in women with ovarian cancer and to assess their role in disease process. The present study is composed of 85 women (mean age = 62.03±12.4 yrs) with clinically and pathologically confirmed ovarian cancer and 65 healthy females as a control group (mean age = 61±12.1 yrs). ELISA test was achieved for the determination of serum [IgG, IgA, IgM]. The findings of current study illustrated significant (P=0.001) increase in serum IgG, IgA, and IgM levels as compared to co
... Show More|
Background: Double diabetes is the term used to describe situations in which a patient exhibits characteristics that are a combination of type 1 and type 2 Diabetes Mellitus. Metalloendopeptidase or Neprilysin is membrane-bound metallopeptidase. It has a wide range of physiological function and a variety of substrates. It has a significant impact on the proteolytic functions of the kidney, cardiovascular health, immunological response, cell proliferation, and fetal development. It also has a preventative effect on the onset of type 2 diabetes, obesity, and cancer. Objective: The study aims to assess the level of MEP in patients wi |
Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,
... Show MoreA nano-sensor for nitrotyrosine (NT) molecule was found by studying the interactions of NT molecule with new B24N24 nanocages. It was calculated using density functionals in this case. The predicted adsorption mechanisms included physical and chemical adsorption with the adsorption energy of −2.76 to −4.60 and −11.28 to −15.65 kcal mol−1, respectively. The findings show that an NT molecule greatly increases the electrical conductivity of a nanocage by creating electronic noise. Moreover, NT adsorption in the most stable complexes significantly affects the Fermi level and the work function. This means the B24N24 nanocage can detect NT as a Φ–type sensor. The recovery time was determined to be 0.3 s. The sensitivity of pure BN na
... Show MoreCanonical correlation analysis is one of the common methods for analyzing data and know the relationship between two sets of variables under study, as it depends on the process of analyzing the variance matrix or the correlation matrix. Researchers resort to the use of many methods to estimate canonical correlation (CC); some are biased for outliers, and others are resistant to those values; in addition, there are standards that check the efficiency of estimation methods.
In our research, we dealt with robust estimation methods that depend on the correlation matrix in the analysis process to obtain a robust canonical correlation coefficient, which is the method of Biwe
... Show More