Fibro-adenoma is the most common lesion of the breast, it occurs in25%of asymptomatic women (1,2 )
It is usually a disease of early reproductive life, the peak incidence is between the ages15 and 35 years.(3,4) It presents as firm highly mobile, non tender mass .(5)
Less than 5% of fibro-adenomas grow rapidly and display the clinical and histologic characteristics of giant fibro-adenoma which is defined as a-tumour either having a diameter greater than 5 cm. And /or amass weighing more than 500 grams, and are conventionally a benign tumor of breast.(6)
Giant fibro-adenomas appear as well-circumscribed but not encapsulated masses on mammography and solid and the texture is homogenous and hypoechoic with low level echoes on U/S. (6, 7)
It is hormone dependent that lactates during pregnancy and involutes along with the rest of the breast in perimenopause.(5)
Excessive estrogen stimulation and /or receptor sensitivity, or lack of estrogen antagonist havebeen implicated in the etiology. (2)
Giant fibro-adenoma is often confined to one breast as a solitary mass occupying part or the whole breast and in rare cases it may be multifocal and involve both breasts. (8)
Giant fibro-adenomas are benign and do not become malignant. (9)
Histological cut surfaces have a lobulated grey-white myxoid semitransparent to dens fibrous appearance, it consist of epithelial and fibrous components, the pericanalicular fibro-adenoma maintains round and oval dilated ductal spaces whereas in the intracanalicular type the ductal lumens are compressed by polypoid fibrous stroma creating slit –like irregular spaces , the ducts are lined by two layers of cells: epithelial and myoepithelial cells and under influence of hormones the ducts become hyper plastic with papillary formation and more than two layers of cells varies from myxoid and hypo cellular to fibrous and moderately cellular . (2)
Surgical treatment of giant fibroadenoma ranges from shelling the tumour out in case it occupies part of the breast, to simple mastectomy. (10)
Background: As the development of zirconia crown using CAD/CAM technology, the usage of full zirconia crown is gradually increased. The aim of this in-vitro study was to evaluate and contrast the vertical marginal fit of single all-ceramic translucent zirconia crowns constructed from different brands translucent zirconia blanks. Materials and Methods: An acrylic resin model of a left maxillary premolar was prepared all around the tooth with (1 mm) depth and 3D scanning to get fifteen STL files, then distributed into three groups (Imes-icor, Whitepeaks and Dental direct), 3D scanning and milling machine by Imes-icor CAD/CAM devise. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid bucc
... Show Moreيشهد العالم تقدما في كافة مجالات الحياة المختلفة وتزداد الحياة صعوبة يوما بعد يوم, ويزداد البحث في كافة المجالات التي تعمل على خدمة الإنسان ولقد طال هذا التقدم النشاط الرياضي ,فقد يكون لتطور التدريب الرياضي وتنوع أساليبه الدور الكبير في تحقيق اللياقة البدنية التي تعد إحدى أهم الأهداف التي يرمي إليها الدرس في كلية التربية الرياضية . واللياقة البدنية تستمد أهميتها من كونها إحدى مكونات اللياقة الشاملة التي بدو
... Show MorePlant tissue culture techniques were exploited for the micropropigation of Lisianthus (Eustoma grandiflora). Different concentrations of Benzyl adenine (BA), 6- Furfural amino purine (Kinetin), Indol butyric acid (IBA), were investigated in their effects at different micropropagation stages. Three explants (apical shoots, internodes, leaf discs) were used in this study. The effect of the interaction between BA and IBA on shoot multiplication was investigated in increasing the number of shoots on explants. Rooting was also studied after inclusion of IBA and NAA to Murashige and Skoog, 1962 culture medium (MS). During acclimatization stage, different ratios of river sand and peat moss as agricultural media were tested and plantlets survival w
... Show MoreThe aim of the present work is to develop a new class of natural fillers based polymer composites with sawdust (S.D) which used two particle sizes (1.2 μm & 2.3 μm) and different weight percentage from sawdust (10%, 15%, and 20%). The mechanical properties studied include hardness (shore D) for all samples at normal conditions (N.C). The unsaturated polyester (UPE) and its composites samples were immersed in water for 30 days to find the effect of particle size of sawdust (S.D) on the weight gain (Mt %) by water for all the samples, also to find the effect of water on their hardness. The results show that the composite materials of sawdust (S.D) fillers which has particle size (1.2 μm) better than (2.3 μm) particle size bef
... Show MoreAbstract A descriptive (cross sectional) study was conducted to assess psychosocial domain of quality of life for (100) women who had hysterectomy for non malignant indications during 6-12 months post operative. The study carried out in both consultation clinics of Al-Elwiya Maternity Hospital and Baghdad Teaching Hospital from January 5th 2003 to July 10th 2003). The results of the study show that hysterectomy achieved a highly successful outcome in terms of psychological and social adjustments for hysterectomies women, a highly significant differences between quality of life (QoL) and some of demographic cha
The primary objective of this study was to identify the obstacles and problems encountered in the work of sports clubs according to the reality of the application of administrative automation. The present study was conducted in the sports club headquarters of Baghdad within the timeframe of October 2021 to December 2021. In the present study, a descriptive approach was used by the researchers in an analytical style according to the nature of the problem to be studied. The research community of the current study was composed of 100 sports clubs in the governorate of Baghdad. A total of 80 questionnaires were filled by the sample participants, who represented a percentage of 80% of the research community. After processin
... Show MoreCold atmospheric plasma (CAP) is used widely in medical and biological fields because of non-thermal effected. Direct application of plasma is preferred in medical functions, so, direct application of cold plasma has obtained by the floating electrode dielectric barrier discharge (FE-DBD) system. The purpose of this paper to review the effect of (CAP) on the reproductive hormones (testosterone, LH, E2, progesterone, for male rats. The study appeared that no significant effect on E2 and progesterone hormone for all time of exposure, besides this significant difference in LH hormone (P<0.05) at 15 sec, (P<0.0001) at 30, 90 sec and (P<0.001) at 60 sec of exposure to plasma. Added to that significant difference (P<0.01) at 15, 30, 60 sec and no
... Show MoreExperimental investigations had been done in this research to demonstrate the effect of carbon fiber and Ceramic fillers contents on the tribological behaviour of (15% volume fraction) carbon-epoxy composite system under varying volume fraction, load, time and sliding distance. The wear resistance were investigated according to ASTM G99-05standard using pin on disc machine to present the composite tribological behaviour. The influence of three ceramic fillers, granite, perlite and calcium carbonate (CaCO3), on the wear of the carbon fabric reinforced epoxy composites under dry sliding conditions has been investigated. The effect of variants in volume fraction, applied load, time and sliding distance on the wear behaviour of po
... Show MoreBackground: The healing period for bone–implant contact takes 3–6 months or even longer. Application of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) to implant surfaces has been of great interest on osseointegration due to its osteoinductive potential. The objective of this study was to evaluate the effect of ErhBMP-2 on implant stability. Materials and methods: A total of 48 dental implants were inserted in 15 patients. Twenty four implants coated with 0.5 mg/ml ErhBMP-2 (study group). The other 24 implants were uncoated (control group). Each patient was received at least two dental implants at the same session. Both groups were followed with repeated implant stability measurements by me
... Show More