Background: Tumors of the oral cavity are under
estimated in general dental and medical practice,
some authors describe it as the forgetting disease,
others wondering if the attention paid to this disease
compared to its fatality (The 5-year survival rate is
about 50%) is enough for disease control? However;
this disease deserves a comprehensive assessment by
all dental and medical fields assumed to examine the
oral cavity regularly, especially otolaryngologist.
Objectives: To find out the sensitivity and specificity
of clinical examination in diagnosing oral tumors and
premalignant conditions by otolaryngologist.
Methods: Across sectional retrospective study was
conducted in the:
-study design: Cross sectional.
-settings: Ear Nose Throat (ENT)departments in
Al-kindy Teaching Hospital
and Al-Yarmouk Teaching Hospital.
On Patients attending ENT department with oral
presentation.
The outcome variables includes: The sensitivity,
specificity, positive predictive value (Pv+ve), negative
predictive value (PV-ve), and the accuracy of clinical
examination in diagnosing oral tumors and
premalignant conditions in ENT clinic.
Results: The results revealed a high sensitivity and
specificity for otolaryngologist in diagnosing
malignant conditions and premalignant lesions of the
oral cavity.
Conclusion: The study highlights the need for fixed
clinical criteria for early diagnosis of premalignant
conditions and oral tumors
Simple, sensitive and economical spectrophotometric methods have been developed for the determination of cefixime in pure form. This method is based on the reaction of cefixime as n-electron donor with chloranil to give highly colored complex in ethanol which is absorb maximally at 550 nm. Beer's law is obeyed in the concentration ranges 5-250 µg ml-1 with high apparent molar absorptivities of 1.52×103 L.mole-1. cm-1.
A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.
... Show MoreIn this study three reactive dyes (blue B, red R and yellow Y) in single , binary and ternary solution were adsorbed by activated carbon AC in equilibrium and kinetic experiments. Surface area, Bulk and real density, and porosity were carried out for the activated carbon.
Batch Experiments of pH (2.5-8.5) and initial concentration (5-100) mg/l were carried out for single solution for each dye. Experiments of adsorbent dosage effect (0.1-1)g per 100 ml were studied as a variable to evaluate uptake% and adsorption capacity for single dyes(5, 10) ppm, binary and ternary (10) ppm of mixture solutions solution of dyes. Langmuir, and Freundlich, models were used as Equilibrium isotherm models for single solution. Extended Langmuir and Freun
Activated carbon was Produced from coconut shell and was used for removing sulfate from industrial waste water in batch Processes. The influence of various parameter were studied such as pH (4.5 – 9.) , agitation time (0 – 120)min and adsorbent dose (2 – 10) gm.
The Langmuir and frandlich adsorption capacity models were been investigated where showed there are fitting with langmmuir model with squre regression value ( 0.76). The percent of removal of sulfate (22% - 38%) at (PH=7) in the isotherm experiment increased with adsorbent mass increasing. The maximum removal value of sulfate at different pH experiments is (43%) at pH=7.
The purpose of this paper, is to study different iterations algorithms types three_steps called, new iteration,
The inhibitive effect of imidazol on the dissolution of Zn in (1M) HCl has been studied. The inhibion effect of imidazol ,protection efficiency and the corrosion rate of Zn in (1M) HCl were investigated at various concentrations (1x 10-3 – 5x10-3) M and tempearture range (285-328) K. The corrosion inhibitive of Zn by imidazol was studied using weight loss measurement and analytical titration of the amounts of dissolved zinc in acidic solution in presence and absent of imidazol. It was observed that imidazol led to protection efficiency reached to (88.93)% when (10)mM imidazol concentration was used. A linear relationship came true between (C/?) and (C); where (?) is the coverage of Zn surface by imidazol which could be obtained from
... Show More

