Back ground: Visceral leishmaniasis is endemic in the
middle and south of Iraq, it involves mostly infants. The
disease is observed mainly among rural areas that are far
from equipped medical centers. Therefore, there is a need
for anon- invasive, cost- effective, reliable, easily
available and fast method of diagnosis of this dngerous
disease.
Objective: The aim was to compare the validity and
predictive values of the recombinant K39 antigen (rK39)
test with that of the indirect fluorescent antibody test
(IFAT) test (the usual laboratory method) in the detection
of visceral leishmaniasis.
Methods: A Cross-sectional study was done in ALMansour Pediatric Hospital (in AL-Rusafa), and Central
Pediatric Hospital (in AL-Karkh) in Baghdad for 6
months duration (from the 1st of December 2004 to 30th of
May 2005). Children less than five years who suspected to
be infected with visceral leishmaniasis were selected and
investigated by IFAT test and rK39 dipstick strip.
Results: The validity of rK39 test when evaluated with
the standard methods IFAT test showed a sensitivity of
90.5%, specificity of 90.7%, predictive value positive of
77.9%, predictive value negative of 96.4% and 90.7%
accuracy.
Conclusions: The rK39 antigen strip test is valid in the
diagnosis of suspected children with visceral
leishmaniasis as the test is rapid, sensitive, and specific
The synthesis of ligands with N2S2 donor sets that include imine, an amide, thioether, thiolate moieties and their metal complexes were achieved. The new Schiff-base ligands; N-(2-((2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio)-acetamide (H2L1) and N-(2-((2,4-di-p-tolyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio) acetamide (H2L2) were obtained from the reaction of amine precursors with 1,4-dithian-2-one in the presence of triethylamine as a base in the CHCl3 medium. Complexes of the general formula K2<
novel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g
... Show MoreA mathematical model constructed to study the combined effects of the concentration and the thermodiffusion on the nanoparticles of a Jeffrey fluid with a magnetic field effect the process of containing waves in a three-dimensional rectangular porous medium canal. Using the HPM to solve the nonlinear and coupled partial differential equations. Numerical results were obtained for temperature distribution, nanoparticles concentration, velocity, pressure rise, pressure gradient, friction force and stream function. Through the graphs, it was found that the velocity of fluid rises with the increase of a mean rate of volume flow and a magnetic parameter, while the velocity goes down with the increasing a Darcy number and lateral walls. Also, t
... Show MoreBackground: The gene encoding a disintegrin and metalloproteinase domain 33 (ADAM33) is known to be associated with asthma in different ethnic groups. In Iraq, among the Arab ethnic background, this association has not yet been highlighted. Methods: One hundred and ninety-two asthmatics were examined; 118 males and 74 females (mean age 38.23 ± 9.13 years). The control group was 183; 110 males and the rest were females. The SNP of rs2280091 A/G (T1) was studied here to determine adam33 genotyping status using polymerase chain reaction–restriction fragment length polymorphism (PCR–RFLP). The level of total IgE was measured using enzyme-linked immunosorbent assay (ELISA). Results: Significant differences (p = 0.004) in the frequencies of
... Show More