Preferred Language
Articles
/
jkmc-73
Electrocautery versus cold steel tonsillectomy comparison study
...Show More Authors

Objective: the objective of this study was to compare the intraoperative blood loss, intraoperative time, postoperative pain and secondary hemorrhage between electrodissection and cold steel dissection tonsillectomy.

Methods: One hundred and six patients were enrolled in this study, the patients were randomly allocated into electrodissection group A (n=51) and cold steel dissection tonsillectomy group B (n=53). All patients are above 7 years and had history of recurrent tonsillitis and/or tonsillar hypertrophy with obstructive symptoms. Intraoperative parameters and postoperative outcome were assessed.

Results: In group A patients had statically significant less operative time and blood loss than group B early postoperative pain was not differ significantly between the two groups, however late onset pain (pain on the 7th day) was significantly higher in group A. There was no significant difference between the groups regarding secondary hemorrhage.

Conclusion: Electrodissection tonsillectomy is rapid, safe and effective method of tonsillectomy with obvious advantage of minimum perioperative blood loss, lower operative time and without early post-operative pain difference when compared to cold steel dissection tonsillectomy. Although it has some disadvantage of late postoperative pain.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Saudi Med J
The frequency of 21-alpha hydroxylase enzyme deficiency and related sex hormones in Iraqi healthy male subjects versus patients with acne vulgaris
...Show More Authors

KE Sharquie, AA Noaimi, BO Saleh, ZN Anbar…, Saudi Med J, 2009 - Cited by 13

View Publication
Scopus (8)
Scopus
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Apr 01 2025
Journal Name
Journal Of Integrative Nursing
ShotBlocker versus vibration device: Which technique reduces pain and increases satisfaction in insulin injection among type 2 diabetes: A randomized controlled trial
...Show More Authors
Objective:

To evaluate the effects of the ShotBlocker and vibration device on pain intensity and patient satisfaction during subcutaneous (SC) insulin injections in hospitalized adults with type 2 diabetes mellitus.

Materials and Methods:

In this randomized controlled trial, 102 patients with type II diabetes mellitus were randomly assigned into 3 groups: 35 patients in the ShotBlocker group, 36 patients in the vibration group, and 31 patients in the control group. ShotBlocker was applied immediately before and during the injection, while the vibration was applied fo

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
...Show More Authors
Abstract<p>This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Improvement of the surface hardness and wear resistant of low carbon steel using laser radiation
...Show More Authors

0

View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Civil Engineering Journal
Assessment Resistance Potential to Moisture Damage and Rutting for HMA Mixtures Reinforced by Steel Fibers
...Show More Authors

Rutting is mainly referring to pavement permanent deformation, it is a major problem for flexible pavement and it is a complicated process and highly observed along with many segments of asphalt pavement in Iraq. The occurrence of this defect is related to several variables such as elevated temperatures and high wheel loads. Studying effective methods to reduce rutting distress is of great significance for providing a safe and along-life road. The asphalt mixture used to be modified by adding different types of additives. The addition of additives typically excesses stiffness, improves temperature susceptibility, and reduces moisture sensitivity. For this work, steel fibres have been used for modifying asphalt mixture as they incorp

... Show More
Scopus (15)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
Anticorrosion Behavior of Deposited Magnetite on Galvanized Steel in Saline Water Using RF-Magnetron Sputtering
...Show More Authors

Thin films of Magnetite have been deposited on Galvanized Steel (G-S) alloy using RF-reactive magnetron sputtering technique and protection efficiency of the corrosion of G-S. A Three-Electrodes Cell was used in saline water (3.5 % NaCl) solution at different temperatures (298, 308, 318 & 328K) using potentiostatic techniques with. Electrochemical Impedance Spectroscopy (EIS) and fitting impedance data via Frequency Response Analysis (FRA) were applied to G-S alloy with Fe3O4 and tested in 3.5 % NaCl solution at 298K.Results taken from Nyquist and Bode plots were analyzed using software provided with the instrument. The results obtained show that the rate of corrosion of G.S alloy increased with increasing the temperatures from 298 t

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology &amp; Applied Science Research
The Response of a Highly Skewed Steel I-Girder Bridge with Different Cross-Frame Connections
...Show More Authors

Braces in straight bridge systems improve the lateral-torsional buckling resistance of the girders by reducing the unbraced length, while in horizontally curved and skew bridges, the braces are primary structural elements for controlling deformations by engaging adjacent girders to act as a system to resist the potentially large forces and torques caused by the curved or skewed geometry of the bridge. The cross-frames are usually designed as torsional braces, which increase the overall strength and stiffness of the individual girders by creating a girder system that translates and rotates as a unit along the bracing lines. However, when they transmit the truck’s live load forces, they can produce fatigue cracks at their connection

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
EFFECT OF TEMPERATURE ON CORROSION OF CARBON STEEL BOILER TUBES IN DILUTE SODUIM CHLORIDE SOLUTION
...Show More Authors

The corrosion behavior of carbon steel at different Temperatures and in water containing different sodium chloride
concentrations under 3 bar pressure has been investigated using weight loss method . The carbon steel specimens were
immersed in water containing (100,400,700,1000PPM) of NaCl solution and under temperature was increased from
(90-120ºC) under pressures of 3 bar. The results of this investigation indicated that corrosion rate increased with NaCl
concentrations and Temperature.

View Publication Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Improvement of Surface Roughness Quality for Stainless Steel 420 Plate Using Magnetic Abrasive Finishing Method
...Show More Authors

     An experimental study was carried out to improve the surface roughness quality of the stainless steel 420 using magnetic abrasive finishing method (MAF). Four independent operation parameters were studied (working gap, coil current, feed rate, and table stroke), and their effects on the MAF process were introduced. A rotating coil electromagnet was designed and implemented to use with plane surfaces. The magnetic abrasive powder used was formed from 33%Fe and 67% Quartz of (250µm mesh size). The lubricant type SAE 20W was used as a binder for the powder contents. Taguchi method was used for designing the experiments and the optimal values of the selected parameters were found. An empirical equation representing the r

... Show More
View Publication Preview PDF