Background: Ambulatory peritoneal dialysis
introduced by Popvich et al (13) in 1978 , consists of a
four to five hours lavage of peritoneal cavity with 2000
ml of glucose solution .It remains a useful method for
treating patients with end stage renal failure till renal
transplantation becomes possible.
Objectives: The aim of the study is to evaluate the
value of cytological changes of mesothelial cells in
dialysate patients.
Methods: Within one year period, 32 cytological
peritoneal fluid samples were collected from patients
with end stage renal failure regardless of the underlying
causes, admitted to the dialyzing unit in Kadimya
Teaching Hospital. Smears were prepared and fixed in
95 % ethyl alcohol and then stained with H & E stain to
be interpreted by the same pathologist.
Results: Thirty two samples of peritoneal fluid were
obtained from patients in peritoneal dialysis with a
mean age of 54.8 years and male to female ratio of
about 1.9: 1.
Twenty two had short term dialysis were compared with
10 patients with long term dialysis.
Gross examination of the samples revealed clear yellow
fluid. Macroscopical examination showed no evidence
of inflammatory cells with increased exfoliation,
cellularity and three dimensional mesothelial cellular
clustering pattern with increased nuclear size. No
statistical significances were found in the changes seen
in cytological smears between both groups but
remarkable nuclear changes were shown in both of
them.
Conclusion: This study demonstrated that peritoneal
dialysis of any duration can induce significant atypical
changes in mesothelial cells. The pathologist needs to
be aware of these changes and to include peritoneal
dialysis in the list of other benign conditions that cause
reactive mesothelial atypia
The international system that established the United Nations after the end of the Second World War witnessed many changes. These changes overshadowed the nature of the work of the international organization, especially its first and most important executive organ (the Security Council). This has sometimes weakened and dulled the Security Council's role in performing the tasks stipulated in the Charter of the Organization, which has led the Organization itself to work on reforms within it in general and to seek reforms in the Security Council in particular. Academic and advisory efforts were made to submit proposals for amendment to be reflected on the Council's performance effectiveness.
The analytic solution for the unsteady flow of generalized Oldroyd- B fluid on oscillating rectangular duct is studied. In the absence of the frequency of oscillations, we obtain the problem for the flow of generalized Oldroyd- B fluid in a duct of rectangular cross- section moving parallel to its length. The problem is solved by applying the double finite Fourier sine and discrete Laplace transforms. The solutions for the generalized Maxwell fluids and the ordinary Maxwell fluid appear as limiting cases of the solutions obtained here. Finally, the effect of material parameters on the velocity profile spotlighted by means of the graphical illustrations
Conservative pipes conveying fluid such as pinned-pinned (p-p), clamped–pinned (c-p) pipes and clamped-clamped (c-c) lose their stability by buckling at certain critical fluid velocities. In order to experimentally evaluate these velocities, high flow-rate pumps that demand complicated fluid circuits must be used.
This paper studies a new experimental approach based on estimating the critical velocities from the measurement of several fundamental natural frequencies .In this approach low flow-rate pumps and simple fluid circuit can be used.
Experiments were carried out on two pipe models at three different boundary conditions. The results showed that the present approach is more accurate for est
... Show MoreThe laminar fluid flow of water through the annulus duct was investigated numerically by ANSYS fluent version 15.0 with height (2.5, 5, 7.5) cm and constant length (L=60cm). With constant heat flux applied to the outer duct. The heat flux at the range (500,1000,1500,2000) w/m2 and Reynolds number values were ≤ 2300. The problem was 2-D investigated. Results revealed that Nusselt number decrease and the wall temperature increase with the increase of heat flux. Also, the average Nusselt number increase as Re increases. And as the height of the annulus increase, the values of the temperature and the local and average Nusselt number increase.

The effect of 0.662MeV gamma radiation on the optical properties of the CdTe thin films was studied. 300nm thickness of CdTe samples were irradiated with doses (10, 20, 30,60krad) in room temperature. The absorption spectra for all the samples were recorded using UV- Visible spectrometer in order to calculate the energy gap, width of localized states and optical constants(refractive index, extinction coefficient, real and imaginary parts of dielectric constant). The optical energy gap was found to decrease from (1.53 to 1.48 eV), while the width of localized states increased from (1.34 to 1.49 eV) with the increasing of radiation dose. The behavior of energy gap with the irradiation dose makes the material a good candidate for dosimetry
... Show MoreAtenolol is one of beta-adrenergic receptor blocking agent. It is widely used for the treatment of hypertension as a selective antihypertensive drug. But long term usage of atenolol may cause one of the cardiovascular diseases like myocardial infarction. To prove the relationship between atenolol and cardiovascular disease, measurement of creatinekinase-MB as a diagnostic indicator in early and long term usage of this drug by hypertensive patients is recommended. A comparative study was conducted in Al-Yarmouk Teaching Hospital–Emergency Department- on 30 hypertensive patients using atenolol. They were divided into (2) groups A and B according to the duration of the drug usage. Group A- (15) patients with a mean age (56
... Show MoreThe heat transfer and flow resistance characteristics for air flow cross over circular finned tube heat exchanger has been studied numerically and experimentally. The purpose of the study was to improve the heat transfer characteristics of an annular finned-tube heat exchanger for better performance. The study has concentrated on the effect of the number of perforations and perforations shapes on the heat transfer and pressure drop across a staggered finned tube heat exchanger. The Numerical part of present study has been performed using ANSYS Fluent 14.5 using SST Turbulent model, while the experimental study consist from a test rig with different models of heat exchangers and all required measurement devices were build
... Show More