Background: Blood vessels injury is one of the most
common causes of medical emergencies that admitted to
hospitals and at the same time it regarded as one of the
most important causes of death. They may represent less
than 15% of all injuries; they deserve special attention
because of their severe complications.
Objective: The aim of the present study is to assess
anatomically the injures of major arteries and veins in the
lower limb with their management.
Methods: The present study extended from April 2006 to
February 2007, in which 65 patients with lower limb
vascular injury were examined in Emergency Department
and Forensic Medicine Department of Tikrit Teaching
Hospital in Salah-Aldin governorate. Diagnosis was made
by clinical diagnosis alone, or in combination with
angiography. Some surgical interferences as vascular
repair was carried out, but if not possible the interposition
graft was used by great saphenous vein for vascular
reconstruction.
Results: The total cases were 65 patients (49 males and 16
females), ranging from 16 years to 67 years with a mean
age of 41.5±6.4 years. Penetrating trauma was the main
cause of injury for 52 patients. Seventeen cases had
bilateral limbs vascular injuries. Arterial injuries were most
common in the femoral arteries, followed by the tibial and
finally the popliteal arteries. Vascular repair were
performed in 16 cases, while in 11 cases great saphenous
vein interposition graft were done. There were 17 cases
associated with venous injury, of which 11 cases had
surgical vascular repair, and 6 had vein graft interposition.
There were concomitant femur fractures in 2 cases, fibula
fractured in 3, tibia fractured in 1 and the foot bones
fractured in 3.
Conclusion: Lower limb vascular injured patient should be
transferred to vascular surgery centers as soon as possible.
After first aid management, anticoagulant treatment may be
started post operatively to prevent the propagation of the
thrombosis. Early fasciotomy is done if there is any
suspicion of occurrence of compartment syndrome.
Pharmaceuticals have been widely remaining contaminants in wastewater, and diclofenac is the most common pharmaceutical pollutant. Therefore, the removal of diclofenac from aqueous solutions using activated carbon produced by pyrocarbonic acid and microwaves was investigated in this research. Apricot seed powder and pyrophosphoric acid (45 wt%) were selected as raw material and activator respectively, and microwave irradiation technique was used to prepare the activated carbon. The raw material was impregnated in pyrophosphoric acid at 80◦C with an impregnation ratio of 1: 3 (apricot seeds to phosphoric acid), the impregnation time was 4 h, whereas the power of the microwave was 700 watts with a radiation time of 20 min. A series o
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreAlpha shape theory for 3D visualization and volumetric measurement of brain tumor progression using magnetic resonance images
In this work, a vertical pulsating heat pipe heat exchanger (PHPHE) was designed for waste heat recovery, exchanging thermal energy between two air streams in a counterflow configuration. The heat exchanger consists of six rows, each row consists of one pulsating heat pipe (PHP), and each PHP has six turns. The working fluid used in the heat pipe was acetone with fill ratios of 50%, 60%, and 70%. The effect of evaporator inlet temperature at 40, 45, and 50°C and air velocity at 0.5, 0.7, and 0.9 m/s on the pulsating heat pipes consisting of three sections- evaporator, condenser, and adiabatic, whose dimensions were 25 x 25 x 10 cm, was studied. At the same time, the condenser temperature was maintained at 26°C. The system’s th
... Show MoreAs a result of rapid industrialization and population development, toxic chemicals have been introduced into water systems in recent decades. Because of its excellent efficiency and simple design, the three-dimensional (3D) electro-Fenton method has been used for the treatment of wastewater. The goal of the current study is to explore the efficiency of phenol removal by the 3D electro-Fenton process, which is one of the advanced oxidation processes (AOPs). In the present work, the effect of the addition of granular activated carbon (GAC) particles to the electro-Fenton system as the third electrode would be investigated in the presence of graphite as the anode and nickel foam as the cathode, which is the source of electro-generated hydrogen
... Show MoreEnvironmental pollution is experiencing an alarming surge within the global ecosystem, warranting urgent attention. Among the significant challenges that demand immediate resolution, effective treatment of industrial pollutants stands out prominently, which for decades has been the focus of most researchers for sustainable industrial development aiming to remove those pollutants and recover some of them. The liquid membrane (LM) method, specifically electromembrane extraction (EME), offers promise. EME deploys an electric field, reducing extraction time and energy use while staying eco-friendly. However, there's a crucial knowledge gap. Despite strides in understanding and applying EME, optimizing it for diverse industrial pollutant
... Show MoreRestoration of degraded lands by adoption of recommended conservation management practices can rehabilitate watersheds and lead to improving soil and water quality. The objective was to evaluate the effects of grass buffers (GBs), biomass crops (BCs), grass waterways (GWWs), agroforestry buffers (ABs), landscape positions, and distance from tree base for AB treatment on soil quality compared with row crop (RC) (corn [