Background: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit after the first visit
monthly for three successive months. For the purpose of
comparison (30) thirty volunteers admitted to this study as
control having same age range. The (160) patients were
categorized into two groups.
Group (A) includes (70) patients with ischemic heart
disease with complications like pulmonary oedema,
myocardial infarction, recent admission to coronary care
unit because of recurrent severs chest pain. Group (B)
includes (90) patients with ischemic heart disease without
any of the above complications. Myocardial performance
index is done by using the four chambers view and pulse
wave and curser along the mitral inflow of the blood jet.
Results: Assessment of left ventricular function by using
the myocardial performance index in group A was more
significant than using the ejection fraction in comparison to
the control group (P value 0.02, 0.03 respectively) the same
was found in group B in comparison to control group (P
value 0.01; 0.05 respectively).
Conclusion The myocardial performance index (MPI) in
the control groups was 0.44-0.36 MS indicating that its
range is very narrow in the control group, The (MPI) in the
two groups of patients was high in comparisons with
control group
This paper discusses reliability R of the (2+1) Cascade model of inverse Weibull distribution. Reliability is to be found when strength-stress distributed is inverse Weibull random variables with unknown scale parameter and known shape parameter. Six estimation methods (Maximum likelihood, Moment, Least Square, Weighted Least Square, Regression and Percentile) are used to estimate reliability. There is a comparison between six different estimation methods by the simulation study by MATLAB 2016, using two statistical criteria Mean square error and Mean Absolute Percentage Error, where it is found that best estimator between the six estimators is Maximum likelihood estimation method.
Objective: To determine the correlation between the second derivative of digital pulse wave and the QT variability index. Method: The cross-sectional study was conducted from October 2021 to May 2022 at the Department of Physiology, College of Medicine, University of Mustansiriyah, Baghdad, Iraq, and comprised healthy women. Samples were raised by simple random technique. Digital pulse waves were captured using a fingertip pulse wave transducer. Lab Chart Pro version 7.2 was used to automatically detect and quantify the amplitude of A, B, C, D and E waves expressed by the second derivative. QT interval of each beat was recorded by electrocardiogram, and was calculated automatically via Lab chart Pro version 7.2 without averaging. D
... Show MoreThe study aims to use the European Excellence Model (EFQM) in assessing the institutional performance of the National Center for Administrative Development and Information Technology in order to determine the gap between the actual reality of the performance of the Center and the standards adopted in the model, in order to know the extent to which the Center seeks to achieve excellence in performance to improve the level of services provided and the adoption of methods Modern and contemporary management in the evaluation of its institutional performance.
The problem of the study was the absence of an institutional performance evaluation system at the centre whereby weaknesses (areas of improvement) and st
... Show MoreThe study aims to identify the mechanical and electrical activities of the heart according to the energy systems of advanced players and to detect the differences between the energy systems in terms of the mechanical and electrical activities of the heart for advanced players. It was clear from the results of the significance of the differences between the three groups according to the energy systems of the advanced players in all research variables that (the non-oxygenic system "Lactic"), which represents the advanced players in the arches (800 m, 1500 m) was the first in most tests of mechanical and electrical activities of the heart, which is (Margaria-Kalamen, Wingate, systolic muscle strength of the heart FC, Stroke Volume SV
... Show MoreIn this paper, the process for finding an approximate solution of nonlinear three-dimensional (3D) Volterra type integral operator equation (N3D-VIOE) in R3 is introduced. The modelling of the majorant function (MF) with the modified Newton method (MNM) is employed to convert N3D-VIOE to the linear 3D Volterra type integral operator equation (L3D-VIOE). The method of trapezoidal rule (TR) and collocation points are utilized to determine the approximate solution of L3D-VIOE by dealing with the linear form of the algebraic system. The existence of the approximate solution and its uniqueness are proved, and illustrative examples are provided to show the accuracy and efficiency of the model.
Mathematical Subject Classificat
... Show MoreThe effects of three different additives formulations namely Lubrizol 21001, HiTEC 8722B and HiTEC 340 on the efficiency of VII namely OCP of three base lubricating oils namely 40 stock and 60 stock and 150 stock at four temperatures 40, 60, 80 and 100oC were investigated. The efficiency of OCP is decreased when blended with 4 and 8 wt% of Lubrizol 21001 for all the three base oil types. But it is increased when adding 4 wt% and 8 wt% of H-8722B in 40 stock. While for 60 stock and 150 stock the OCP efficiency decreased by adding 4 and 8 wt% of H-8722B. In the other hand, it is decreased with a high percentage by adding 4 and 8 wt% of H-340 for 60 stock and 150 stock and for 40 stock it is increased by adding 4 wt% of H-340 and decreased
... Show MoreAPDBN Rashid, Southern African Linguistics and Applied Language Studies, 2023
Background : Coronary artery disease is theunderlying cause in approximately two thirds of
patients with systolic heart failure ;
Coronary artery angiogriphy may be useful to
define the presence ,
Anatomical characteristics ,and functional
significance of Coronary artery disease in
selected heart failure patients with or without signs
and aymptoms of Coronary artery disease.
Objectives: to verify the clinical usefulness of
coronary angiography (CA) in congestive heart
failure (CHF) patients with no history of ischemic
heart disease and to identify predictive factors for
performing coronary angiography to patients with
congestive heart failure with no obvious ischemia.
Methods :this is a cross-ses
Research on the automated extraction of essential data from an electrocardiography (ECG) recording has been a significant topic for a long time. The main focus of digital processing processes is to measure fiducial points that determine the beginning and end of the P, QRS, and T waves based on their waveform properties. The presence of unavoidable noise during ECG data collection and inherent physiological differences among individuals make it challenging to accurately identify these reference points, resulting in suboptimal performance. This is done through several primary stages that rely on the idea of preliminary processing of the ECG electrical signal through a set of steps (preparing raw data and converting them into files tha
... Show More