Background: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit after the first visit
monthly for three successive months. For the purpose of
comparison (30) thirty volunteers admitted to this study as
control having same age range. The (160) patients were
categorized into two groups.
Group (A) includes (70) patients with ischemic heart
disease with complications like pulmonary oedema,
myocardial infarction, recent admission to coronary care
unit because of recurrent severs chest pain. Group (B)
includes (90) patients with ischemic heart disease without
any of the above complications. Myocardial performance
index is done by using the four chambers view and pulse
wave and curser along the mitral inflow of the blood jet.
Results: Assessment of left ventricular function by using
the myocardial performance index in group A was more
significant than using the ejection fraction in comparison to
the control group (P value 0.02, 0.03 respectively) the same
was found in group B in comparison to control group (P
value 0.01; 0.05 respectively).
Conclusion The myocardial performance index (MPI) in
the control groups was 0.44-0.36 MS indicating that its
range is very narrow in the control group, The (MPI) in the
two groups of patients was high in comparisons with
control group
n-Hexane conversion enhancement was studied by adding TCE (Trichloro-ethylene) on feed stream using 0.3%Pt/HY zeolite catalyst. All experiments were achieved at atmospheric pressure and on a continuous laboratory unit with a fixed bed reactor at a temperature range 240-270◦C, LHSV 1-3h-1, H2/nC6 mole ratio 1-4.
By adding 435 ppm of TCE, 49.5 mole% conversion was achieved at LHSV 1h-1, temperature of 270ºC and H2/nC6 mole ratio of 4, while the conversion was 18.3 mol% on the same catalyst without adding TCE at the same conditions. The activation energy decreased from 98.18 for pure Pt/HY zeolite to 82.83 kJ/mole by adding TCE. Beside enhancement the activity, selectivity and product distribution enhanced by providing DMB (Dimethyl b
In this research an experimental study has done for testing the thermal performance of selective surfaces used in solar collectors for substrate of iron, galvanized iron and aluminum which are commercially available. The coating process for the samples has done in two ways, the electroplating and the chemical spray pyrolysis. The results of the thermal performance test of these samples are comparing with the thermal performance of a sample without paint and other paint with black paint without shines commercially available. For the electroplated samples, the performance study has done for different immersion time in plating bath, the
distance between electrical poles, the current density, and area ratio of the sample plated area to
In many applications such as production, planning, the decision maker is important in optimizing an objective function that has fuzzy ratio two functions which can be handed using fuzzy fractional programming problem technique. A special class of optimization technique named fuzzy fractional programming problem is considered in this work when the coefficients of objective function are fuzzy. New ranking function is proposed and used to convert the data of the fuzzy fractional programming problem from fuzzy number to crisp number so that the shortcoming when treating the original fuzzy problem can be avoided. Here a novel ranking function approach of ordinary fuzzy numbers is adopted for ranking of triangular fuzzy numbers with simpler an
... Show MoreThe organizational culture is an effective control mechanism that dictates the behavior of employees and according to their intellectual and social orientations, so it is considered a more powerful way to control employee orientations and determine their management according to organizational rules and regulations, as it was one of the most important factors determining the performance of organizations, while organizational performance is a measure of what the organization has achieved from the objectives of the scheme To ensure that it faces various changes and remains within the global competition, and to reach that it was necessary to identify the most prominent and most important research problems in knowing the extent of com
... Show MoreThe control function of important functions in the system of government for several reasons , perhaps the most important of the magnitude of spending and spending in one of the tools adopted in the implementation of the control function.
Perhaps the most prominent stages of the development budget in terms of setup and use in the budget programs and performance , as specialized literature show its importance in strengthening financial and operationl
... Show MoreA field experiment was carried out in one of the orchards of Al-Qassim district in Babel Governorate to find out the ability of a locally manufactured platform to serve palm trees by working in flat and uneven orchard land, palm tree heights of 4, 8, and 12 meters, and it performs pollination, pruning and harvesting services. The time of ascent and descent, the palm service, and the palm/hour productivity were measured. A randomized complete block design with three replications used a split split-plot arrangement. The nature of the land (flat or uneven) represented the main plots, the height of the palm trees (4, 8, 12) meters, the sub-plots, and the palm service operations (pollinati
The effect of internal acoustic excitation on the leading-edge, separated boundary layers and the aerodynamic performance of NACA23015 cross section airfoil are examined as a function of excitation location with ranging frequency range (50-400) Hz of the introduced acoustic. Tests are separately conducted in two sections, open type wind tunnels at the Reynolds number of 3.3x105 for measurement at angle of attack (0, 3, 6, 9 &12) deg. and 3x104 for the visualization at angle of attack (12) deg. based on the airfoil chord. Results indicated that the excitation frequency and the excitation location are the key parameters to alter the flow properties and thus to improve the aerodynamic performance. The most effective excitation frequency
... Show More