Preferred Language
Articles
/
jkmc-691
Is co2 laser Hemorrhoidectomy superior to conventional open Hemorrhoidectomy?
...Show More Authors

Background: Hemorrhoids are one of the most
common surgical conditions .Conventional
haemorrhoidectomy was the traditional operation for
the treatment of hemorrhoids. Other modalities of
treatment had been used as an alternative operations
including CO2 laser haemorrhoidectomy.
Objectives: To determine the outcome of treatment
of hemorrhoids by using CO2 laser
haemorrhoidectomy and its advantages over
conventional surgery
Methods: This is a retrospective comparative
interventional study of 1024 case of third degree
haemorhoids selected out of 1300 case of
hemorrhoids of different degrees, admitted to
ALKINDY, ALYERMOUK teaching hospitals and
ABD ALMAGEED private hospital, from May 1998
to July 2002,they were treated by CO2 laser
haemorrhoidectomy and conventional surgery. They
are divided into 2 groups randomly, 512 cases treated
by CO2 laser (group A), 512 cases treated by
conventional surgery (group B). Both groups were
studied regarding operative time, hospital stay,
healing time, post operative complications and cost
effectiveness.
Results: In GROUP A, the operative time ranged
from 10 to 20 minutes with an average of 13 minutes.
The hospital stay ranged from 4 to 12 hours with a
mean time of 10 hours as all cases were treated as
day cases. Post operative pain was minimal in 50% of
patients and required simple analgesia for treatment
while 50% had no pain. Bleeding occurred in less
than 1% of cases, anal stenosis 3.3%, Infection
recorded in 0.58% of patients.In GROUP B, The
operative time ranged from 15 to 25 minutes with an
average time of (19) minutes, hospital stay ranged
from 24 to 48 hours with a mean time of 28 hours
.Post operative pain recorded in all the patients
(100%) and required narcotic analgesia for treatment,
25 patients (4.8%) had varying degrees of bleeding,
40 patients (7.8%) had infection, 25 patients (4.8%)
had anal stenosis.In group A due to shorter hospital
stay, earlier healing of wounds, earlier return to work
which was within 7 to 10 days, the surgical treatment
proved to be cost effective

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Warts Treatment by 810 nm Diode Laser Irradiation: A New Approach
...Show More Authors

The present work was done in an attempt to build systematic procedures for treating warts by 810 nm diode laser regarding dose parameters, application parameters and laser safety. The study was done in Al- Kindy Teaching Hospital in Baghdad, Iraq during the period from 1st October 2003 till 1st April 2004. Fifteen patients completed the treatment and they were followed for the period of 3 months. Recalcitrant and extensive warts were selected for the study. Patients were randomly divided into 3 groups to be treated by different laser powers 9, 12 and 15 W, power density of 286 W/cm2, 381W/cm2, 477 W/cm2 pulse duration of 0.2 s, interval of 0.2 s and repeated pulses were used. The mode of application was either circular or radial. Pain oc

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Prospect of CW Raman Laser in Silicon- on- Insulator Nano-Waveguides
...Show More Authors
 
Numerical analysis predicts that continuous-wave (CW) Raman lasing is possible in Silicon-On-insulator (SOI) nano-waveguides, despite of presence of free carrier absorption. The scope of this paper lies on lasers for communication systems around 1550 nm wavelength. Two types of waveguide structures Strip and Rib waveguides have been incorporated. The waveguide structures have designed to be 220 nm in height. Three different widths of (350, 450, 1000) nm were studied. The dependence of lasing of the SOI Raman laser on effective carrier lifetime was discussed, produced by tow photon absorption. At telecommunication wavelength of 1550 nm, Raman lasing threshold was calculated to be 1.7 mW in Rib SOI waveguide with dimen
... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitat

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystal

... Show More
View Publication
Publication Date
Fri Jun 18 2004
Journal Name
Iraqi Journal Of Laser
Design and Construction of Semiconductor Laser Range Finder for Target Designation
...Show More Authors

The aim of this research is to design and construct a semiconductor laser range finder
operating in the near infrared range for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of 0.904 mm wavelength with a beam expander,
and the receiver with its collecting optics. The characteristics of transmitter pulse width were 200ns and
threshold current 10 Amp. and maximum operating current 38 Amp. The repetition rate was set at 660 Hz
and maximum output power about 1 watt. The divergence of the beam was 0.268o. A special computer
code was used for optimum optical design and laser spot size analysis and for calculation of atmosphere
attenuation.

View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Spot Welding of Dissimilar Metals Using an Automated Nd:YAG Laser System
...Show More Authors

An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.

View Publication Preview PDF
Publication Date
Fri Dec 12 2003
Journal Name
Iraqi Journal Of Laser
Frequency Doubled Nd: YAG Laser for the Treatment of Diabetic Retinopathy
...Show More Authors

The present study was conducted with a view to determine whether focal laser therapy result in visual recovery and regression of macular edema in patients with non proliferative diabetic retinopathy and maculopathy ,and whether combined focal and scatter laser therapy in patients with proliferative diabetic retinopathy and maculopathy results in visual recovery ,regression of macular edema and regression of the risk factors. In the present work, a frequency doubled Nd: YAG laser was used for the treatment of diabetic retinopathy. The study evaluates 41 eyes of 33 diabetic patients both with Insulin Dependent Diabetes Mellitus IDDM, (n=16) and Non Insulin Dependent Diabetes Mellitus NIDDM, (n=17) with diabetic retinopathy divided into two

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Optics & Laser Technology
Finite element thermal analysis for PMMA/st.st.304 laser direct joining
...Show More Authors

This work is concerned with building a three-dimensional (3D) ab-initio models that is capable of predicting the thermal distribution of laser direct joining processes between Polymethylmethacrylate (PMMA) and stainless steel 304(st.st.304). ANSYS® simulation based on finite element analysis (FEA) was implemented for materials joining in two modes; laser transmission joining (LTJ) and conduction joining (CJ). ANSYS® simulator was used to explore the thermal environment of the joints during joining (heating time) and after joining (cooling time). For both modes, the investigation is carried out when the laser spot is at the middle of the joint width, at 15 mm from the commencement point (joint edge) at traveling time of 3.75 s. Process par

... Show More
View Publication
Scopus (48)
Crossref (44)
Scopus Clarivate Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Reconstruction of 3D Shape for an Object using Laser Scanning Triangulation
...Show More Authors

This paper presents a method of designing and constructing a system capable of acquiring
the third dimension and reconstructs a 3D shape for an object from multi images of that object using
the principle of active optical triangulation. The system consists of an illumination source, a photo
detector, a movement mechanism and a PC, which is working as a controlling unit for the hard ware
components and as an image processing unit for the object multi view raw images which must be
processed to extract the third dimension. The result showed that the optical triangulation method
provides a rapid mean for obtaining accurate and quantitative distance measurements. The final
result's analysis refers to the necessity of usin

... Show More
View Publication Preview PDF