Preferred Language
Articles
/
jkmc-662
Antenatal diagnosis of myometrial invasion in anterior placenta previa by transabdominal color Doppler ultra sound
...Show More Authors

Background: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by color Doppler at 32 or more weeks of
gestation to determine the possibility of myometrial
invasion depending on the above color Doppler
criteria.
Results: Out of 48 patients eleven exhibited
characteristic Doppler imaging pattern highly specific
for placenta accreta and inccreta according to
preceding criteria , one patient had false positive color
Doppler imaging result, 5 patients underwent
caesarian hysterectomy , the remaining five were
treated conservatively by uterine artery ligation and
other conservative measures because of bleeding
from the lower uterine segment.
Conclusion Color Doppler sonography is highly
sensitive and
specific in the antenatal diagnosis of placenta previa
accreta .If a strong suspicion is found before delivery
,appropriate location and timing for delivery should be
considered ,to allow access to adequate surgical
personel and equipment ,preoperative blood
preparation to reduce morbidity and mortality.
Journal title
Ultrasound in obstetric and gynecology ISSUN 0960-
7692 Source 2000 Vol 15 In 1 PP. 28-35 (22rel)

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Doppler Phenomenon on the Speed of Blood Flow
...Show More Authors

This research studying the phenomenon of Doppler (frequency Doppler) as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of  disease and morbidity  of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 16 2018
Journal Name
Al-academy
The Aesthetics of the Digital Sound Effects in Television Drama
...Show More Authors

The sound effects in TV dramas achievements have become very important not only in terms of function and implementation, but at a greater and wider level in terms of artistic and aesthetic values, which are produced and employed in the most important world artistic achievements of drama, using the latest and most prominent technologies and equipment and according to the expressive and dramatic values expressed by these modern digital sound effects. Therefore, the researcher chose the aesthetic effect of digital sound effects in television drama to identify the aesthetic aspects provided by digital sound effects by employing them and their accompaniment for the image.

The researcher, therefor, divided this study into the methodolo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 01 2017
Journal Name
2017 Annual Conference On New Trends In Information & Communications Technology Applications (ntict)
An efficient color quantization using color histogram
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of The College Of Languages (jcl)
Sound Assimilation in English and Arabic: a Contrastive Study
...Show More Authors

      This piece of research deals with assimilation as one of the phonological processes in the language. It is a trial to give more attention to this important process in English language with deep explanation to its counterpart in Arabic. in addition, this study sheds light on the points of similarities and differences concerning this process in the two languages. Assimilation in English means two sounds are involved, and one becomes more like the other.

     The assimilating phoneme picks up one or more of the features of another nearby phoneme. The English phoneme /n/ has t

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Multiwavelet and Estimation by Interpolation Analysis Based Hybrid Color Image Compression
...Show More Authors

Nowadays, still images are used everywhere in the digital world. The shortages of storage capacity and transmission bandwidth make efficient compression solutions essential. A revolutionary mathematics tool, wavelet transform, has already shown its power in image processing. The major topic of this paper, is improve the compresses of still images by Multiwavelet based on estimation the high Multiwavelet coefficients in high frequencies sub band  by interpolation instead of sending all Multiwavelet coefficients. When comparing the proposed approach with other compression methods Good result obtained

View Publication Preview PDF
Publication Date
Mon Sep 01 2025
Journal Name
Journal Of Dentistry
Influence of zirconia thickness and background color on color matching accuracy of monolithic zirconia restorations
...Show More Authors

objective: To evaluate the influence of monolithic zirconia brand, thickness, and substrate color on color matching accuracy when optically coupled to abutment substrates. Methods: A total of 180 samples of two brands of monolithic zirconia [Prettau Anterior (PA), Ceramill Zolid FX Multicolor (CZ)] were prepared in three different thicknesses (0.8 mm, 1.5 mm, and 2 mm) with a standardized 10 mm diameter. Color properties of the samples were assessed using spectrophotometry at baseline and after coupling to three substrate types: standard dentin, discolored dentin, and titanium. Color differences (ΔE) were calculated and statistically analyzed by 3-way ANOVA and pairwise comparison ( α=0.05). Results: The brand and material thickness, at

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Oct 16 2018
Journal Name
International Journal Of Pharmaceutical Quality Assurance
Isolation and Detection of Candida tropicalis from Aborted Placenta in Al-Najaf city/Iraq
...Show More Authors

Background: Candida tropicalis is one of the most causes of vulvovaginal candidiasis (VVC) in women. Systemic candidiasis and candidemia may also occur in pregnancies. Objective: This study was carried out to detect and isolate of this yeast from aborted placenta, which may cause severe complications such as spontaneous abortion. Materials and methods: Fresh aborted placenta were collected and washed by normal saline to remove the blood. Then, cut it into portions and place it in test tube containing 5 ml of normal saline. Finally, shake for 10 minutes, after that, cultured for microbial isolation. Isolation and detection were done by some conventional methods with Api candida and CHROMagar. Results: The results showed that four iso

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Teikyo Medical Journal
Evaluation of Serum Angiogenic and Anti-angiogenic Markers in Pregnant Women with Placenta Accreta
...Show More Authors

Over the last 40 years, rate of cesarean delivery has risen from less than10% to over 30% around the world, and almost simultaneously a 10-foldraise in the incidence of placenta accrete spectrum. Fine coordinationamong vascular endothelial growth factor, soluble fms-like tyrosine kinase1 and placental growth factor is important for normal placentaldevelopment and trophoblast invasion. To measure and compare the levelsof circulating vascular endothelial growth factor, placental growth factorand soluble fms-like tyrosine kinase 1 in pregnant women with placentaaccreta to a control group. A case control study which involved one hundredpregnant females were recruited from the Obstetric ward in BaghdadTeaching Hospital who were pregnant with 28

... Show More
Publication Date
Wed Jun 01 2011
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Blind Color Image Steganography in Spatial Domain
...Show More Authors

WA Shukur, FA Abdullatif, Ibn Al-Haitham Journal For Pure and Applied Sciences, 2011 With wide spread of internet, and increase the price of information, steganography become very important to communication. Over many years used different types of digital cover to hide information as a cover channel, image from important digital cover used in steganography because widely use in internet without suspicious.

View Publication
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Tamper Detection in Color Image
...Show More Authors

In this work a fragile watermarking scheme is presented. This scheme is applied to digital color images in spatial domain. The image is divided into blocks, and each block has its authentication mark embedded in it, we would be able to insure which parts of the image are authentic and which parts have been modified. This authentication carries out without need to exist the original image. The results show the quality of the watermarked image is remaining very good and the watermark survived some type of unintended modification such as familiar compression software like WINRAR and ZIP

View Publication Preview PDF
Crossref (1)
Crossref