Objective: Detection the presumptive prevalence of
silent celiac disease in patients with type 1 diabetes
mellitus with determination of which gender more
likely to be affected.
Methods: One hundred twenty asymptomatic patients
[75 male , 45 female] with type 1 diabetes mellitus
with mean age ± SD of 11.25 ± 2.85 year where
included in the study . All subjects were serologically
screened for the presence of anti-tissue transglutaminase
IgA antibodies (anti-tTG antibodies) by Enzyme-
Linked Immunosorbent Assay (ELISA) & total IgA
was also measured for all using radial
immunodiffusion plate . Anti-tissue transglutaminase
IgG was selectively done for patients who were
expressing negative anti-tissue transglutaminase IgA
with low total IgA levels & results were compared
to that obtained from healthy 60 persons with mean
age ± SD for them was 15.25 ± 3.85 year .
Results : Fourteen out of one hundred twenty (11.66
% ) diabetic patients had expressed positivity to antitissue
transglutaminase IgA compared to 1/60 ( 1.66
%) of non diabetic patients who had expressed such
positivity , P value equals to 0.0221 & it is
considered to be statistically significant. Three out of
one hundred twenty (2.5 % ) diabetic patients had
expressed total IgA deficiency whereas all of non
diabetic patients were expressing total IgA within
the normal range , P value equals to 0.55 & it is
considered to be not statistically significant. All of
three diabetic patients with total IgA deficiency were
not showing positivity to anti-tissue transglutaminase
IgG . Six mals & Eight female of those with type 1
diabetes mellitus had expressed positivity to anti-tissue
transglutaminase IgA , P value equals to 0.1426 &
it is considered to be not statistically significant .
Conclusion : There is an increased prevalence of IgA antitissue transglutaminase antibodies ( 11.66 % ) in children & adolescent with type 1 diabetes mellitus in comparison with control group.
Background:- Cholesterol is high in ascetic fluid due
to malignancy and other causes of exudates.
Objective:-To use cholesterol as a marker to
differentiate between exudative and transudative
ascetic fluid and to compare that with other routine
parameters.
Methods:-Twenty eight patients were included in this
study 17 females with mean age of 41.9 years, 11
males with mean age of 48.2 years. The patients were
divided in group I suspected transudate, and group II
suspected exudate according to history and clinical
examination.
Ascetic fluid samples were sent for total protein,
albumin, and cholesterol measurement blood samples
were sent for serum protein and albumin measurement.
Results:-In this
Human serum albumin (HSA) nanoparticles have been widely used as versatile drug delivery systems for improving the efficiency and pharmaceutical properties of drugs. The present study aimed to design HSA nanoparticle encapsulated with the hydrophobic anticancer pyridine derivative (2-((2-([1,1'-biphenyl]-4-yl)imidazo[1,2-a]pyrimidin-3-yl)methylene)hydrazine-1-carbothioamide (BIPHC)). The synthesis of HSA-BIPHC nanoparticles was achieved using a desolvation process. Atomic force microscopy (AFM) analysis showed the average size of HSA-BIPHC nanoparticles was 80.21 nm. The percentages of entrapment efficacy, loading capacity and production yield were 98.11%, 9.77% and 91.29%, respectively. An In vitro release study revealed that HSA-BIPHC nan
... Show MoreEvidences indicate that human beings were preoccupied with extreme forms of mental and psychic experiences long before they were recorded in literature. Greek myths and legends appear to include symbolizations of delusions, mania, and other bizarre forms of thought and behaviuor. The figure of the mad man or woman is analogous to the wild man, or the imaginary being who appears in various forms throughout western literature and art. Various studies refer to the notion of the wild man as a response to a persistent psychological urge. This urge gives an external expression and a valid form to the impulses of reckless physical self-assertion which is believed to be hidden in all of us, but is normally kept under control. Such impulses were exp
... Show MoreThe Boltzmann equation has been solved using (EEDF) package for a pure sulfur hexafluoride (SF6) gas and its mixtures with buffer Helium (He) gas to study the electron energy distribution function EEDF and then the corresponding transport coefficients for various ratios of SF6 and the mixtures. The calculations are graphically represented and discussed for the sake of comparison between the various mixtures. It is found that the various SF6 – He content mixtures have a considerable effect on EEDF and the transport coefficients of the mixtures
This study was conducted for evaluating the cytotoxic effect of heat stable enterotoxin a (STa) produced by enterotoxigenic Escherichia coli on the proliferation of primary cancer cell cultures, obtained from tumor samples that were collected from (13) cancer patients and as follows: (five colon cancer patients, two bladder cancer patients, two breast cancer patients, two stomach cancer patients and two lung cancer patients), and on normal cell line (rat embryonic fibroblast / REF) (in vitro) with the use of different concentrations starting from (1) mg/ml and ending with (0.0002) mg/ml by making two fold serial dilutions by using the 96- well microtiter plate, and in comparison with negative (PBS) and positive (MMC, at concentration
... Show MoreBackground: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show Morein this paper copper oxide (cuO thin films were prepared by the method of vacum thermal evaporation a pressure.
the bank sect for any country is very important because its represent a major nerve to feed a verity economic and finance activities .development any state measure by development banking sets and its represent important factor to investors attract . and because important of this subject ,teen accounting rule is a specialized for it .its related by Disclosures in the Financial Statements Of Banks and The Similar Institutions, its accredit by auditing and accounting standard consul in republic of Iraq.in date 10/28/1998. &
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show More