Objective: Detection the presumptive prevalence of
silent celiac disease in patients with type 1 diabetes
mellitus with determination of which gender more
likely to be affected.
Methods: One hundred twenty asymptomatic patients
[75 male , 45 female] with type 1 diabetes mellitus
with mean age ± SD of 11.25 ± 2.85 year where
included in the study . All subjects were serologically
screened for the presence of anti-tissue transglutaminase
IgA antibodies (anti-tTG antibodies) by Enzyme-
Linked Immunosorbent Assay (ELISA) & total IgA
was also measured for all using radial
immunodiffusion plate . Anti-tissue transglutaminase
IgG was selectively done for patients who were
expressing negative anti-tissue transglutaminase IgA
with low total IgA levels & results were compared
to that obtained from healthy 60 persons with mean
age ± SD for them was 15.25 ± 3.85 year .
Results : Fourteen out of one hundred twenty (11.66
% ) diabetic patients had expressed positivity to antitissue
transglutaminase IgA compared to 1/60 ( 1.66
%) of non diabetic patients who had expressed such
positivity , P value equals to 0.0221 & it is
considered to be statistically significant. Three out of
one hundred twenty (2.5 % ) diabetic patients had
expressed total IgA deficiency whereas all of non
diabetic patients were expressing total IgA within
the normal range , P value equals to 0.55 & it is
considered to be not statistically significant. All of
three diabetic patients with total IgA deficiency were
not showing positivity to anti-tissue transglutaminase
IgG . Six mals & Eight female of those with type 1
diabetes mellitus had expressed positivity to anti-tissue
transglutaminase IgA , P value equals to 0.1426 &
it is considered to be not statistically significant .
Conclusion : There is an increased prevalence of IgA antitissue transglutaminase antibodies ( 11.66 % ) in children & adolescent with type 1 diabetes mellitus in comparison with control group.
Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl
... Show MoreIn this work preparation of antireflection coating with single layer of MgO using pulsed laser deposition (PLD) method which deposit on glass substrate with different thicknesses (90 and 100) nm annealed at temperature 500 K was done.
The optical and structural properties (X-ray diffraction) have been determined. The optical reflectance was computed with the aid of MATLAB over the visible and near infrared region. Results shows that the best result obtained for optical performance of AR'Cs at 700 shots with thickness 90 nm nanostructure single layer AR'Cs and low reflection at wavelength 550 nm.
Solubility problem of many of effective pharmaceutical molecules are still one of the major obstacle in theformulation of such molecules. Candesartan cilexetil (CC) is angiotensin II receptor antagonist with very low water solubility and this result in low and variable bioavailability. Self- emulsifying drug delivery system (SEDDS) showed promising result in overcoming solubility problem of many drug molecules. CC was prepared as SEDDS by using novel combination of two surfactants (tween 80 and cremophore EL) and tetraglycol as cosurfactant, in addition to the use of triacetin as oil. Different tests were performed in order to confirm the stability of the final product which includes thermodynamic study, determination of self-emulsificat
... Show MoreThe holmium plasma induced by a 1064-nmQ-switched Nd:YAG laser in air was investigated. This work was done theoretically and experimentally. Cowan code was used to get the emission spectra for different transition of the holmium target. In the experimental work, the evolution of the plasma was studied by acquiring spectral images at different laser pulse energies (600,650,700, 750, and 800 mJ). The repetition rates of (1Hz and 10Hz) in the UV region (200-400 nm). The results indicate that, the emission line intensities increase with increasing of the laser pulse energy and repetition rate. The strongest emission spectra appeared when the laser pulse energy is 800mJ and 10 Hz repetition rate at λ= 345.64nm, with the maximum intensi
... Show MoreEnd of the twentieth century witnessed by the technological evolution Convergences between the visual arts aesthetic value and objective representation of the image in the composition of the design of the fabric of new insights and unconventional potential in atypical employment. It is through access to the designs of modern fabrics that address the employment picture footage included several scenes footage from the film, which focuses on research and analytical as a study to demonstrate the elements of the picture and the organization of its rules and how to functioning in the design of fabrics, Thus, it has identified the problem by asking the following: What are the elements of the picture footage and how the functioning of the struct
... Show MoreIn this research, a variable stiffness actuator is proposed to enhance the damping of the mechanical vibrating system. The frequency response analysis of the vibrating system is dependant in order to analyze and synthesis this semi-active damping, where the suggested process is using active filter to estimate the present frequency of the vibration system, and this will limit the value of the stiffness of the vibrated system. Two active filter s are needed, low-pass-filter (LPF) to choose the higher stiffness of the actuator at small frequencies as well as more damping and high-pass-filter (HPF) to choose the lower stiffness of the actuator at high frequencies as well as more damping, and so
... Show More