Preferred Language
Articles
/
jkmc-616
Success rate of Percutaneous Coronary Intervention of Chronic Total Occlusion in Ibn Al-Baitar Hospital for cardiac surgery and Al-Nassyeria cardiac center
...Show More Authors

Back ground: Chronic total occlusion (CTO) of coronary arteries remains one of the most challenging lesion subsets in interventional cardiology even with the development of medical devices and operator expertise. Successful revascularization results in improved in angina status ,increased exercise capacity and reduces the need for lat CABG surgery .
Objectives: This study sought to determine the overall procedural success rate of percutaneous coronary intervention (PCI) for CTOs and to examine the relation between variables such as; patients’ characteristics, risk factors, lesion characteristics and procedural success rate.
Methods: In this study ,clinical and coronary angiography data of (80) patients with CTO who underwent PCI between May 2009 and May 2010 in Ibn Al-Baitar Hospital for cardiac surgery and Al-Nassryia cardiac center were prospectively analyzed . The clinical data were collected using the patients files and angiographic data by review of their films.
Results: There were (80) Patients with CTO ,They included 62 men (77.5%) and 18 women (22.5%) ,Age range 36-76 year with mean age 55±8.75 and male to female ratio was 3:1 .The procedural success rate of PCI was 66 patients (82.5%). All 23patients(100%) with lesionlength less than 15 mm had successful PCI compared to 43 out of 57 patients in whom the lesion was more than 15mm (75.4%) p value < 0.01. The procedure was successful in 54 patients out of 60 with tapered stump(90%) compared to 12 out of 20 patients with abrupt stump(60%) p value <0.005.In CTO lesion with angulations less than 45 degree ,the procedure was successful in 27 patients out of 28 (96.4%)compared to 39 out of 52 patients in whom the angulations was more than 45 degree 52(75%) p value<0.01. The most common cause of procedural un success was inability of guide wire crossing through the totally occluded segments which represented 11(78.5%), Inability to cross the lesion with a balloon in 2 patients(14.2%) and inability to dilate balloon in one patient (7.1%) P<0.001.
Conclusion: Percutaneous coronary intervention of chronic total occlusion is an effective therapeutic procedure with high success rate 82.5%. The length of chronic total occlusion ,degree of angulations and stump morphology are strong predictors of success procedure.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 11 2023
Journal Name
Applied Sciences
A Preliminary Study and Implementing Algorithm Using Finite State Automaton for Remote Identification of Drones
...Show More Authors

Electronic remote identification (ER-ID) is a new radio frequency (RF) technology that is initiated by the Federal Aviation Authorities (FAA). For security reasons, traffic control, and so on, ER-ID has been applied for drones by the FAA to enable them to transmit their unique identification and location so that unauthorized drones can be identified. The current limitation of the existing ER-ID algorithms is that the application is limited to the Wi-Fi and Bluetooth wireless controllers, which results in a maximum range of 10–20 m for Bluetooth and 50–100 m for Wi-Fi. In this study, a mathematical computing technique based on finite state automaton (FSA) is introduced to expand the range of the ER-ID RF system and reduce the ene

... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Nov 03 2015
Journal Name
Journal Of Natural Sciences Research
Implementation of remote sensing for vegetation studying using vegetation indices and automatic feature space plot
...Show More Authors

Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Theoretical Study for Performance Enhancement of Air Solar Collectors by Using Different Absorbers
...Show More Authors

An experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm) , was tested under climate condition of  Baghdad city with a (43° tilt angel)  by using  the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width), which was manufactured from iron painted with a black matt.

The experimental test deals with five types of absorber:-

 Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media  on absorber .

The hourly and average efficiency of the collectors

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 03 2026
Journal Name
International Journal Of Engineering Pedagogy (ijep)
Design of a Hybrid AI-Driven Engineering Model for Energy-Efficient and Sustainable Educational Systems
...Show More Authors

A substantial percentage of the world’s energy consumption (almost 40%) and carbon dioxide (CO2) emissions (around 37%) come from the construction industry, especially schools. This work presents a new hybrid artificial intelligence (AI) engineering model that aims to maximize energy performance on campuses in a holistic way. Modules for data-driven forecasting, metaheuristic optimization, and real-time adaptive control are all part of the concept. A thorough energy simulation of a university campus building is used in conjunction with the AI model to assess its performance through a co-simulation framework. Findings show that yearly peak electricity demand may be reduced by 18.7% and total site energy consumption by 22.4% when co

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reverse Osmosis Polyamide Membrane for the Removal of Blue and Yellow Dye from Waste Water
...Show More Authors

The present work aims to study the removal of dyes from wastewater by reverse osmosis process. Two dyes were used direct blue 6, and direct yellow. Experiments were performed with feed concentration (75 – 450 ppm), operation temperature (30 – 50 oC) and time (0.2 – 2.0 hr). The membrane used is thin film composite membrane (TFC). It was found that modal permeate concentration decreases with increasing feed concentration and time operating, while permeate concentration increases with increasing feed temperature. Also it was found that product rate increase with increasing temperature, but it decrease with increasing feed concentration and time. The concentration of reject solution showed an increase with increasing feed concentratio

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 30 2026
Journal Name
International Journal Of Engineering Pedagogy (ijep)
The Impact of Intelligent Adaptive Learning on Flexible Thinking and Academic Achievement for Undergraduate Students
...Show More Authors

In the knowledge society, artificial intelligence (AI) forms a cornerstone of global education. This quasi-experimental study examines the impact of an Intelligent Adaptive Learning Strategy (IALS) on flexible thinking (FT) and academic achievement among 60 3rd-year undergraduate students at the College of Education/University of Baghdad (experimental n = 30; control n = 30). The IALS was implemented via an AI-supported educational platform, while the control group received conventional instruction. Post-test intervention assessments included an FT test (10 items, content validity = 0.89, Cronbach’s α = 0.87) and an achievement test (10 objective items, α = 0.85). Results revealed statistically significant superiority of the exp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Engineering
Checking the Accuracy of Selected Formulae for both Clear Water and Live Bed Bridge Scour
...Show More Authors

Due to severe scouring, many bridges failed worldwide. Therefore, the safety of the existing bridge (after contrition) mainly depends on the continuous monitoring of local scour at the substructure. However, the bridge's safety before construction mainly depends on the consideration of local scour estimation at the bridge substructure. Estimating the local scour at the bridge piers is usually done using the available formulae. Almost all the formulae used in estimating local scour at the bridge piers were derived from laboratory data. It is essential to test the performance of proposed local scour formulae using field data. In this study, the performance of selected bridge scours estimation formulae was validated and sta

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Investigation of Load and Pressure Distribution on Wing with Wake Rollup for Low Speed Aircraft
...Show More Authors

The presented work shows a preliminary analytic method for estimation of load and pressure distributions on low speed wings with flow separation and wake rollup phenomena’s. A higher order vortex panel method is coupled with the numerical lifting line theory by means of iterative procedure including models of separation and wake rollup. The computer programs are written in FORTRAN which are stable and efficient.

      The capability of the present method is investigated through a number of test cases with different types of wing sections (NACA 0012 and GA(W)-1) for different aspect ratios and angles of attack, the results include the lift and drag curves, lift and pressure distributions along the wing s

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Acta Pharmaceutica Sinica B
Discovery of a potent and dual-selective bisubstrate inhibitor for protein arginine methyltransferase 4/5
...Show More Authors

View Publication
Scopus (26)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Structures
Behaviour and design of the ‘lockbolt’ demountable shear connector for sustainable steel-concrete composite structures
...Show More Authors

In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the t

... Show More
View Publication Preview PDF
Scopus (39)
Crossref (40)
Scopus Clarivate Crossref