Objective: To compare the efficacy and safety of isosorbide mononitrate (IMN) versus misoprostol used to induce labour for overdue pregnancy.
Setting: A prospective randomized clinical study conducted at AL-Elwiya Maternity Teaching Hospital in Baghdad from Jan. 2008 to Dec. 2008.
Method: One hundred and fifty women with over due pregnancy (past date and posterm pregnancy) referred for induction of labour with Bishop scores <_ 5 were randomly allocated to receive either forty mg isosorbide mononitrate (IMN) tablet as a single vaginal dose (n=75) or fifty mcg misoprostol vaginally (n=75) every six hrs for a maximum of three doses. Amniotomy and/or oxytocin infusion is considered when Bishop scores frankly progressed (augmentation) or used when no improvement achieved after 24 hour (induction). Adverse effects of medications, induction - delivery interval, mode of delivery and neonatal outcome were recorded and subjected to statistical analysis.
Results: Isosorbide mononitrate was associated with less adverse effects than misoprostol especially regarding uterine tachysystol (0 with isosorbide mononitrate vs 12% with misoprostol, P<0.01) and hyperstimulation (0 with isosorbide mononitrate vs 16% with misoprostol, p<0.01) but the induction - delivery interval with isosorbide mononitrate group was significantly longer compared with misoprostol (26.3±7.3hrs vs 15.4±5.4 hrs , p<0.01). Oxytocin was added to 70 women (93.3%) used isosorbide mononitrate while to 15 women (20%) used misoprostol (p<0.001). Caesarean rate was not significantly different between the two groups, but the indications were different, dystocia is the major cause (73.3%) with isosorbide mononitrate while persistent non-assuring fetal heart rate pattern (64%) in the misoprostol group.
Conclusion: Cervical ripening and induction of labour using isosorbide mononitrate resulted in fewer adverse effects but it was less effective than misoprostol.
In the present study, advanced oxidation process / heterogeneous photocatalytic process (UV/TiO2/Fenton) system was investigated to the treatment of oily wastewater. The present study was conducted to evaluate the effect of hydrogen peroxide concentration H2O2, initial amount of the iron catalyst Fe+2, pH, temperature, amount of TiO2 and the concentration of oil in the wastewater. The removal efficiency for the system UV/TiO2/Fenton at optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=5, temperature =30oC, TiO2=75mg/L) for 1000mg/L load was found to be 77%.
Aluminum foil cover around the re
... Show MoreThe goal beyond this Research is to review methods that used to estimate Logistic distribution parameters. An exact estimators method which is the Moment method, compared with other approximate estimators obtained essentially from White approach such as: OLS, Ridge, and Adjusted Ridge as a suggested one to be applied with this distribution. The Results of all those methods are based on Simulation experiment, with different models and variety of sample sizes. The comparison had been made with respect to two criteria: Mean Square Error (MSE) and Mean Absolute Percentage Error (MAPE).
In this work, an analytical approximation solution is presented, as well as a comparison of the Variational Iteration Adomian Decomposition Method (VIADM) and the Modified Sumudu Transform Adomian Decomposition Method (M STADM), both of which are capable of solving nonlinear partial differential equations (NPDEs) such as nonhomogeneous Kertewege-de Vries (kdv) problems and the nonlinear Klein-Gordon. The results demonstrate the solution’s dependability and excellent accuracy.
The Ge0.4Te0.6 alloy has been prepared. Thin films of Ge0.4Te0.6 has been prepared via a thermal evaporation method with 4000A thickness, and rate of deposition (4.2) A/sec at pressure 2x10-6 Torr. The A.C electrical conductivity of a-Ge0.4Te0.6 thin films has been studied as a function of frequency for annealing temperature within the range (423-623) K, the deduced exponent s values, was found to decrease with increasing of annealing temperature through the frequency of the range (102-106) Hz. It was found that, the correlated barrier hopping (CBH) is the dominant conduction mechanism. Values of dielectric constant ε1 and dielectric loss ε2 were found to decrease with frequency and increase with temperature. The activation energies have
... Show MoreBotnet detection develops a challenging problem in numerous fields such as order, cybersecurity, law, finance, healthcare, and so on. The botnet signifies the group of co-operated Internet connected devices controlled by cyber criminals for starting co-ordinated attacks and applying various malicious events. While the botnet is seamlessly dynamic with developing counter-measures projected by both network and host-based detection techniques, the convention techniques are failed to attain sufficient safety to botnet threats. Thus, machine learning approaches are established for detecting and classifying botnets for cybersecurity. This article presents a novel dragonfly algorithm with multi-class support vector machines enabled botnet
... Show MoreThe research aims to investigate the effects of GMAW or MIG welding process on the mechanical properties of dissimilar aluminum alloys 2024-T351 and AA 6061- T651. A series of experimental techniques have been conducted to evaluate mechanical properties of the alloys, by carrying out hardness, tensile and bending tests for welded and un-welded specimens.
Metal inert gas (MIG) has been carried out on sheet metal using ER- 4043(AlSi5) as a filler metal and argon as shielded gas. The welded joints were tested by X-ray radiography and Faulty pieces were excluded.
Welding joints without defects are subjected to heat treatment including heating the joints in furnace to 170 °C for half an hour then air cooling to rel
... Show MorePredicting vertical stress was indeed useful for controlling geomechanical issues since it allowed for the computation of pore pressure for the formation and the classification of fault regimes. This study provides an in-depth observation of vertical stress prediction utilizing numerous approaches using the Techlog 2015 software. Gardner's method results in incorrect vertical stress values with a problem that this method doesn't start from the surface and instead relies only on sound log data. Whereas the Amoco, Wendt non-acoustic, Traugott, average technique simply needed density log as input and used a straight line as the observed density, this was incorrect for vertical computing stress. The results of these methods
... Show MoreTopological indices provide important insights into the structural characteristics of molecular graphs. The present investigation proposes and explores a creative graph on a finite group G, which is known as the RIG. This graph is designated as ΓRS G2(4) indicating a simple undirected graph containing elements of G. Two distinct ertices are regarded as nearly the same if and only if their sum yields a non-trivial involution element in G. RIGs have been discovered in various finite groups. We examine several facets of the RIG by altering the graph through the conjugacy classes of G. Furthermore, we investigate the topological indices as applications in graph theory applying the distance matrix of the G2(4) group.