Background: Obesity is an evolving major health problem in both developed and developing countries. Traditional obesity indices as body mass index, waist circumference, waist-hip-ratio are well known measures to identify obese subjects, however, neck circumference as an index of upper-body obesity was found to be a simple and time-saving screening measure that can be used to identify obesity and the likelihood of developing metabolic syndrome in type 2 diabetic patients.
Aim: to investigate the relationship of neck circumference (NC) to obesity and metabolic syndrome in Iraqi subjects with type 2 diabetes.
Methods: The study group included 90 type 2 diabetic subjects (48 men and 42 women) aged 30-68 years. The subjects were those who attending The Specialized Center for Endocrinology and Diabetes/Baghdad. Main indicators studied included Neck Circumference (NC), waist circumference (WC), waist-to-hip ratio (WHR), body mass index (BMI), blood pressure, fasting blood glucose, and lipoprotein levels.
Results: Pearson's correlation coefficients indicated a significant association between NC and body circumference, and waist-hip-ren and from 0.014 to less than 0.0001 in women). Also NC is positively correlated with systolic blood pressure (SBP), diastolic blood pressure (DBP), triglycerides (TGA), fasting blood glucose level (p value from 0.092 to less than 0.0001). Cross tabulation between NC and BMI indicated that NC identified obese persons with 100% sensitivity in men and 90% in women, also a cross tabulation between NC and metabolic syndrome indicated that NC can identify metabolic syndrome with 100% sensitivity in both men and women. Metabolic syndrome was identified according to a modified criteria proposed by the National Cholesterol Education Program (NCEP) Adult Treatment Panel III (ATPIII).
mass index, waist atio (p <0.0001 in m
Conclusion: Neck circumference is positively correlated with BMI, waist circumference, waist-hip-ratio, and positively correlated with components of metabolic syndrome in Iraqi individuals with type 2 diabetes. Accordingly, the measurement of neck circumference could be useful in clinical screening for obese persons and for persons who are at risk of developing metabolic syndrome.
In this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised
IMPLICATION OF GEOMECHANICAL EVALUATION ON TIGHT RESERVOIR DEVELOPMENT / SADI RESERVOIR HALFAYA OIL FIELD
In this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).
New evidence on nanotechnology has shown interest in the creation and assessment of nanoparticles for cancer treatment. Worldwide, a wide range of tumor-targeted approaches are being developed to reduce side effects and boost the efficacy of cancer therapy. One strategy that shows promise is the use of metallic nanoparticles to increase the radio sensitization of the cancer cells while reducing or maintaining the normal tissue complication probability during radiation therapy. In this study, atmospheric plasma was created using argon gas to create Au NPs using the plasma jet scheme, and their ability to induce apoptosis as an anticancer mechanism was tested. Aqueous gold tetrachloride salts (HAuCl4·3H2O) ere used to produce gold nanopartic
... Show MoreThis research presents the possibility of using banana peel (arising from agricultural production waste) as biosorbent for removal of copper from simulated aqueous solution. Batch sorption experiments were performed as a function of pH, sorbent dose, and contact time. The optimal pH value of Copper (II) removal by banana peel was 6. The amount of sorbed metal ions was calculated as 52.632 mg/g. Sorption kinetic data were tested using pseudo-first order, and pseudo-second order models. Kinetic studies showed that the sorption followed a pseudo second order reaction due to the high correlation coefficient and the agreement between the experimental and calculated values of qe. Thermodynamic parameters such as enthalpy change (ΔH
... Show MoreSewage pumping stations are considered an important part of any sewerage system. Pumps failure in these stations means that the pumps are unable to work at the design requirement (flow capacity and head) and that may cause sewer overflow and flooding leading to sewer deterioration. In this paper, two main sewage pumping stations in Baghdad city were selected as case studies, Al- Habibia and Al-Ghazali located on Zublin trunk sewer 3000 mm and Baghdad trunk sewer 1200-2100 respectively. This study focused mainly on the operation of main sewage pumping stations and their effect, both directly and indirectly, on changing hydraulic properties, which leads to an increase in the deterioration of sewage pipes. The hydraulic analysis was co
... Show MoreDielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show More