Background: migraine is a chronic neurovascular disorder characterized by intermittent attacks of sever headache with or without aura that can include various combinations of neurological, gastrointestinal tract (G.I.T), and autonomic changes, without evidence of primary structural abnormalities. The Autonomic nervous system involvement suggested by many symptoms and signs including nausea, diarrhea, constipation, coldness in the extremities, paroxysmal tachycardia and chest pain.
Objectives: To evaluate autonomic functions in patients with migraine and to clarify the autonomic dysfunction weather its sympathetic, parasympathetic, or combined. Also to assess the severity of this dysfunction and its relation to age, gender and type of migraine.
Methods: This study enrolled 60 patients with migraine, 42 females and 18 males with an age range between 14-45 y. with 30 healthy volunteer as control group, The using of a questionnaire paper, autonomic nervous system disability scale and set of autonomic cardiovascular reflexes test were also applied .
Results: The migraineurs with disabling attack may be prone to autonomic nervous system hypofunction which may be either a risk factor for migraine headache, or be a consequence of frequent disabling attacks, moreover autonomic nervous system dysfunction and migraine may share a common neural substrate. The Parasympathetic part of autonomic nervous system is affected more than sympathetic according to Ewing classification of autonomic function tests which is significant statistically in comparison to control, and 16(26.7%) of patients showed definite dysautonomia(score >2) while 44(73.3%) of patients were normal. Palpitation and postural dizziness are the most frequent symptoms in patients with migraine . Autonomic dysfunction among migraineurs is not rare also prolong course of illness is strongly correlated with autonomic dysfunction which is affect parasympathetic part more than sympathetic, for this reason the clinician should look carefully for the autonomic symptoms when they assess patient with migraine because most of those symptoms were disabling
Conclusions: The assessment of autonomic function tests should be a routine work in patient with migraine. The heart rate response to deep breath and valsalva are simple informative and beside to evaluate the parasympathetic part of autonomic nervous system
Using the Internet, nothing is secure and as we are in need of means of protecting our data, the use of passwords has become important in the electronic world. To ensure that there is no hacking and to protect the database that contains important information such as the ID card and banking information, the proposed system stores the username after hashing it using the 256 hash algorithm and strong passwords are saved to repel attackers using one of two methods: -The first method is to add a random salt to the password using the CSPRNG algorithm, then hash it using hash 256 and store it on the website. -The second method is to use the PBKDF2 algorithm, which salts the passwords and extends them (deriving the password) before being ha
... Show MoreStructural buildings consist of concrete and steel, and these buildings have confronted many challenges from various aggressive environments against the materials manufactured from them. It contains high water levels and buildings whose concrete cover may be damaged and thus lead to the deterioration and corrosion of steel. It was important to have an alternative to steel, such as the glass fiber reinforced polymer (GFRP), which is distinguished by its great effectiveness in resisting corrosion, as well as its strong tensile resistance. Still, one of its drawbacks is that it has a low modulus of elasticity. This research article aims to conduct a numerical study using the nonlinear fi
This paper constructs a new linear operator associated with a seven parameters Mittag-Leffler function using the convolution technique. In addition, it investigates some significant second-order differential subordination properties with considerable sandwich results concerning that operator.
In this study, nanocomposites have been prepared by adding
multiwall carbon nanotubes (MWCNTs) with weight ratios (0, 2, 3,
4, 5) wt% to epoxy resin. The samples were prepared by hand lay-up
method. Influence of an applied load before and after immersion in
sodium hydroxide (NaOH) of normality (0.3N) for (15 days) at
laboratory temperature on wear rate of Ep/MWCNTs
nanocomposites was studied. The results showed that wear rate
increases with increasing the applied load for the as prepared and
immersed samples and after immersion. It was also found that epoxy
resin reinforced with MWCNTs has wear rate less than neat epoxy.
The sample (Ep + 5wt% of MWCNTs) has lower wear rate. The
immersion effect in base so
This current study aims to:
1st: The recognizing of Alexithymia level for 6th grade students (Study Specimen) through the next Zero Hypothesis:1. There are no statistically significant differences at (0.05) level between the arithmetic mean of the specimen degrees as a whole and the central assumption for the scale of the lack in emotions expression
2. There are no statistically significant differences at (0.05) level between the arithmetic mean of the male students specimen and the arithmetic meanc of the female students specimen for the scale of Alexithymia.
2nd: ldentification the level of the emotional intelligence among 6th grade students (Study Specimen) through the next Zero Hypothesis:
1) There are no statistically si
In this study, we introduce new a nanocomposite of functionalize graphene oxide FGO and functionalize multi wall carbon nanotube (F-MWCNT-FGO).The formation of nanocomposite was confirmed by FT-IR ,XRD and SEM. The magnitude of the dielectric permittivity of the (F-MWCNT-FGO) nanocomposite appears to be very high in the low frequency range and show a unique negative permittivity at frequencies range from 400 Hz to 4000Hz. The ac conductivity of nanocomposite reaches 23.8 S.m-1 at 100Hz.
Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2
... Show More