Background:-The Modified Alvarado Scoring System (MASS) has been reported to be a cheap and quick diagnostic tool in patients with acute appendicitis. However, differences in diagnostic accuracy have been observed if the scores were applied to various populations and clinical settings.
Objectives:- The purpose of this study was to evaluate the diagnostic value of Modified Alvarado Scoring System in patients with acute appendicitis in our setting.
Methods:-one hundre twenty eight patients ,were included in this study, admitted to Al-Kindy teaching hospital from June 2009 to June 2010. Patients’ age ranged from 8 to 56 years (21±10) they were divided into three groups; paediatrics, child bearing age females & adult males,. MASS was calculated for each patient included as the diagnosis & treatment were done on the bases of surgeon's clinical decision,confirmation was done by histopathological examination. Finally statistics done included negative appendectomy rate, sensitivity,specificity,positive predictive value,negative predictive value & accuracy.
Results:- Our negative appendectomy rate was 19.5% (22.22% for paediatrics 40.9% for females 4.2% for males). MASS showed sensitivity of 61%(92.8% for paediatrics 38% for females & 58% for males), specificity 80% (75% for paediatrics 88% for females & 50% for males), positive predictive value 92%(92.8% for paediatrics 83% for females 50% for males), negative predictive value 33% ( 75%for paediatrics 50% for females 5% for males) & accuracy 65% ( 88.9% for paediatrics 59% for females 58% for males).
Conclusion:- MASS was of limited help to junior doctors in our setting,clinical assessment & experience are still the gold standard for acute appendicitis.
The parameter and system reliability in stress-strength model are estimated in this paper when the system contains several parallel components that have strengths subjects to common stress in case when the stress and strengths follow Generalized Inverse Rayleigh distribution by using different Bayesian estimation methods. Monte Carlo simulation introduced to compare among the proposal methods based on the Mean squared Error criteria.
This work describes the enhancement of phenol red decolorization through immobilizing of laccase in chitosan and enzyme recycling. Commercial laccase from white rot fungus, Trametesversicolor (Tvlac), was immobilizedin to freshly prepared chitosan beads by using glutaraldehyde as a cross linker. Characterization of prepared chitosan was confirmed by FTIR and scanning electron microscope (SEM). Tvlac (46.2 U/mL) immobilized into chitosan beads at 0.8 % glutaraldehyde (v/v) within 24 hrs. Synthetic (HBT) and natural (vanillin) mediators were used to enhance dye decolorizoation. It was found that 89 % of phenol red was decolorized by chitosan beads within 180 min. in the absence of enzyme and mediator, while decolorization percenta
... Show MoreThis research aims to present a proposed model for disclosure and documentation when performing the audit according to the joint audit method by using the questions and principles of the collective intelligence system, which leads to improving and enhancing the efficiency of the joint audit, and thus enhancing the confidence of the parties concerned in the outputs of the audit process. As the research problem can be formulated through the following question: “Does the proposed model for disclosure of the role of the collective intelligence system contribute to improving joint auditing?”
The proposed model is designed for the disclosure of joint auditing and the role
... Show MoreIn this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu
The corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of
... Show MoreIn this paper, we studied the spark corona discharge in tap and distillited waters. The results show the shape of cone that generated on the tip of capillary tube is different with conductivity of liquids. The blue glow appears at the end of capillary tube and the drop extends into a cone. In addition, the conducitivity is affected on the relationship between the appearance of the blue glow discharge with the applied voltage. The size of the cone decreases with an increase in applied voltage. The cone diameter at the base of capillary tube oscillates with period approximately 1 Sec. this oscillates in the cone diameters is due to the change distance between the liquid electrode and the surface of liquid. The intensity of spark corona dis
... Show MoreUse Almtafr Alcderan orange, one of the factors Hashr Alttafaria to study Alatjabh isolates elected on the basis of specifications so that was a positive response with mutagen record and system consisting of three isolates used Alcderan orange graded concentrations and under specific Trov similar conditions Alttafar Pal NTG compared
Background: In this study, the female reproductive system of Columba oenas was examined during the egg laying stage, focusing on its general structure and microscopic characteristics. Methods: Obsessive monitoring operations were performed, as well as different parts of the egg canal, which include infundibulum, magnum, isthmus, uterus and vagina. Result: These parts showed clear anatomical differences, each with special textile features that seem to play distinctive roles related to the growth and movement of eggs. In magnum it was found that the bulk contains clear mucous folds and many secretory glands. The isthmus had a star-shaped lumen and was lined with a false cylindrical epithelium. In the uterus, branching tube glands, ric
... Show MoreThe research focuses on how to reach a mechanism that assists experts, engineers, and others in the architectural & engineering project to verify the co-existence of values and sustainability constituents in it. Research problem shows a clear lack, locally, in the interest to establish a value system and a list that cares about comprehending building components whether considering sustainable building criteria. Hypothesis shows that in order to head towards the applicable sustainable approach of buildings, then a local assessment system should be established to evaluate buildings during its life cycle, and from which buildings would be categorized as sustainable or not. Research aims at establishing main and general
... Show MoreHeuristic approaches are traditionally applied to find the optimal size and optimal location of Flexible AC Transmission Systems (FACTS) devices in power systems. Genetic Algorithm (GA) technique has been applied to solve power engineering optimization problems giving better results than classical methods. This paper shows the application of GA for optimal sizing and allocation of a Static Compensator (STATCOM) in a power system. STATCOM devices used to increase transmission systems capacity and enhance voltage stability by regulate the voltages at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. IEEE 5-bus standard system is used as an example to illustrate the te
... Show More