Preferred Language
Articles
/
jkmc-592
Modified alvarado scoring system. How much helpful?
...Show More Authors

Background:-The Modified Alvarado Scoring System (MASS) has been reported to be a cheap and quick diagnostic tool in patients with acute appendicitis. However, differences in diagnostic accuracy have been observed if the scores were applied to various populations and clinical settings.
Objectives:- The purpose of this study was to evaluate the diagnostic value of Modified Alvarado Scoring System in patients with acute appendicitis in our setting.
Methods:-one hundre twenty eight patients ,were included in this study, admitted to Al-Kindy teaching hospital from June 2009 to June 2010. Patients’ age ranged from 8 to 56 years (21±10) they were divided into three groups; paediatrics, child bearing age females & adult males,. MASS was calculated for each patient included as the diagnosis & treatment were done on the bases of surgeon's clinical decision,confirmation was done by histopathological examination. Finally statistics done included negative appendectomy rate, sensitivity,specificity,positive predictive value,negative predictive value & accuracy.
Results:- Our negative appendectomy rate was 19.5% (22.22% for paediatrics 40.9% for females 4.2% for males). MASS showed sensitivity of 61%(92.8% for paediatrics 38% for females & 58% for males), specificity 80% (75% for paediatrics 88% for females & 50% for males), positive predictive value 92%(92.8% for paediatrics 83% for females 50% for males), negative predictive value 33% ( 75%for paediatrics 50% for females 5% for males) & accuracy 65% ( 88.9% for paediatrics 59% for females 58% for males).
Conclusion:- MASS was of limited help to junior doctors in our setting,clinical assessment & experience are still the gold standard for acute appendicitis.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
Improving Voltage Stability in Kurdistan Power System in Areas with Deficit Power Production by Rescheduling the Active Power Based on PSS/E Simulation
...Show More Authors

This paper aims to improve the voltage profile using the Static Synchronous Compensator (STATCOM) in the power system in the Kurdistan Region for all weak buses. Power System Simulation studied it for Engineers (PSS\E) software version 33.0 to apply the Newton-Raphson (NR) method. All bus voltages were recorded and compared with the Kurdistan region grid index (0.95≤V ≤1.05), simulating the power system and finding the optimal size and suitable location of Static Synchronous Compensator (STATCOM)for bus voltage improvement at the weakest buses. It shows that Soran and New Koya substations are the best placement for adding STATCOM with the sizes 20 MVAR and 40 MVAR. After adding STATCOM with the sizes [20MVAR and 40MV

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Engineering
Comparative Biosorption Of Pb(II), Cr(III) AND Cd(II) Ions In Single Component System By Live And Dead Anaerobic Biomass, Bath Study
...Show More Authors

In this study, dead and live anaerobic biomass was used in biosorption of Pb(II), Cr(III) and Cd(II) ions from a synthetic wastewater. The biosorption was investigated by batch adsorption experiments. It was found that, the biosorption capacities were significantly affected by biosorbent dosage. The process follows Langmuir isotherm (regression coefficient 0.995, 0.99 and 0.987 for Pb(II), Cr(III) and Cd(II) ions, respectively, onto dead anaerobic biomass) model with uniform distribution over the biomass surface. The experimental uptake capacity was 51.56, 29.2 and 28 mg/g for Pb(II), Cr(III) and Cd(II), respectively, onto dead anaerobic biomass, compared with 35, 13.6 and 11.8 mg/g for Pb(II), Cr(III) and Cd(II), respectively, onto live

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
A Mathematical Model of a Thermally Activated Roof (TAR) Cooling System Using a Simplified RC-Thermal Model with Time Dependent Supply Water Temperature
...Show More Authors

This paper presents a computer simulation model of a thermally activated roof (TAR) to cool a room using cool water from a wet cooling tower. Modeling was achieved using a simplified 1-D resistance-capacitance thermal network (RC model) for an infinite slab. Heat transfer from the cooling pipe network was treated as 2-D heat flow. Only a limited number of nodes were required to obtain reliable results. The use of 6th order RC-thermal model produced a set of ordinary differential equations that were solved using MATLAB - R2012a. The computer program was written to cover all possible initial conditions, material properties, TAR system geometry and hourly solar radiation. The cool water supply was considered time

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 30 2026
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adopting the addition of iron waste as a source for iron (II) ion in Electro-Fenton system for the removal of triple dyes
...Show More Authors

Use of electrodes that provide a high surface area for reaction, such as Nickel foam and Carbon Fiber Felt, has proven highly efficient in treating wastewater. In this study, a mixture of dyes (Eosin Y, Methylene Blue, and Methylene Violet) was treated using Ni foam as a cathode and carbon fiber felt as an anode in the Electro-Fenton process, relying on iron waste, such as iron filings, as the catalyst source. The analysis characterization of electrodes and iron filings was determined by Energy dispersive X-Ray (EDX) and Scanning electron microscopy (SEM) tests. The results showed high efficiency in decomposing the dye mixture. The highest Re % 96.4591 which attained after accomplishing the experiments based on Response Surface Method (RSM)

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Ssrn Electronic Journal
Developing a Predictive Model and Multi-Objective Optimization of a Photovoltaic/Thermal System Based on Energy and Exergy Analysis Using Response Surface Methodology
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Nauchforum
COGNITIVE ELEMENTS AND CRITERIA OF THE INFLECTIONAL SYSTEM OF RUSSIAN AND ARABIC LANGUAGUES IN THE PROCCES OF VERBAL COMMUNICATION (COGNUTIVE ANALYSIS OF LANGUAGE STRUCTURE)
...Show More Authors

In this paper we study the selection of cognitive elements and criteria of the inflectional structure of the Russian and Arabic languages in the process of speech communication. Phonetic-physiological principle is the main parameter by which the elements and criteria of cognitive activity in the presented study are distinguished. On the basis of the above mentioned parameter, we select the investigated criteria and elements. The first criterion is semantic, reflects the accordance of the elements of thinking to sound combinations in the studied languages, and allows us to distinguish the second criterion – morphonological. The second criterion depends on the phonetic changes of these combinations occurring in the process of speech activit

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Optimal Bedding Selection with the Specific Soil Type According to the Thrust Forces Generated in the Water Distribution Networks Using the Restraining Joint System
...Show More Authors

A study has been performed to compare the beddings in which ductile iron pipes are buried. In water transmission systems, bends are usually used in the pipes. According to the prescribed layout, at these bends, unbalanced thrust forces are generated that must be confronted to prevent the separation of the bend from the pipe. The bed condition is a critical and important factor in providing the opposite force to the thrust forces in the restraint joint system. Due to the interaction between the native soil and the bedding layers in which the pipe is buried and the different characteristics between them. Also, the interaction with the pipe material makes it difficult to calculate the real forces opposite to the thrust forces and the way they

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Influence of Temperature and Flow Velocity on the Corrosion Inhibition of Low Carbon Tubes in Recirculating Water System by a Dicomponent Inhibitor Blend
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Innovation, Creativity And Change
The techno-strategy of the management information system and its role in enhancing risk management in the general directorate of school and sport activity
...Show More Authors

The importance of this research lies in shedding light on the concept of techno-strategy for information management from vital and important topics that showed response for change in all areas of life. As this necessitates the updating and changing of it in order to achieve its strategic goals and enhance its technological advantage. The research problem looked at the role of the information technology system (ITS) in enhancing risk management in general directorates for sports and school activity from the viewpoint of its department heads. The research aimed at the relationship of information techno-strategy in risk management and the ratios of the contribution of information techno-strategy in risk management from the viewpoint of heads o

... Show More
Preview PDF
Scopus (1)
Scopus
Publication Date
Fri Nov 26 2021
Journal Name
Nanomaterials
Solidification Enhancement in a Multi-Tube Latent Heat Storage System for Efficient and Economical Production: Effect of Number, Position and Temperature of the Tubes
...Show More Authors

Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that

... Show More
View Publication
Scopus (14)
Crossref (13)
Scopus Clarivate Crossref